TEHANLD heat pump efficiency: 10 outdoor models compared

TEHANLD has 10 heat pump outdoor models certified with this refrigerant group, in 12 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes TEHANLD makes. TEHANLD has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
10
AHRI certifications
12
Efficiency index
24%
Typical model vs same-size, same-type peers (10 models)
Meet CEE 2025
40%
4 models

How TEHANLD compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
TEHANLD against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of TEHANLD’s own modelsTEHANLD is strongest on capacity retention at 5°F (its typical model beats 34% of comparable models) and weakest on HSPF2 (12%).
  • TEHANLD
  • Middle half of its models
  • Other ranked manufacturers
TEHANLD

Source: AHRI Directory, NEEP · as of

Average peer percentile of TEHANLD’s models
RatingBeats comparable modelsRankRaw median
Efficiency index10 models scored24%Not ranked—
COP at 5°F10 models scored17%Not ranked1.75
Capacity retention at 5°F10 models scored34%Not ranked70%
HSPF210 models scored12%Not ranked7.5
SEER210 models scored28%Not ranked17.0
EER210 models scored26%Not ranked10.2
Heating capacity at 5°F10 models scored22%Not ranked7,400 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
TEHANLD’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • TEHANLD (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons1024%17%12%28%

Every TEHANLD model in the market

TEHANLD’s 10 models with a known size and duct type, over the shape of the whole catalog.
TEHANLD models by size and ratingColoured: TEHANLD · grey shapes: all 14,508 models · lines: catalog medians by size
  • TEHANLD models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 10 tehanld models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top TEHANLD models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 TEHANLD cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1DMLHT1W-09R4CBPH2TEHANLDwith ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH21 ton9,000 Btu/h · Non-ducted89%1.909.08,00022.0CEE 25CEE 26Xcel1217563445Non-ducted, up to 1.5 tons47.6
2DMLHT1W-12R4CBPH2TEHANLDwith ductless indoor unit DMLHT1G-12R4CBPH2Also listed as DMLHT1W-12R4BBPH21 ton12,000 Btu/h · Non-ducted70%1.869.08,40022.0CEE 25CEE 26Xcel1217563447Non-ducted, up to 1.5 tons29.6
3DMLHT1W-09R4CBPH1TEHANLDwith ductless indoor unit DMLHT1G-09R4CBPH11 ton9,000 Btu/h · Non-ducted78%1.757.57,00017.0Xcel1217563441Non-ducted, up to 1.5 tons20.8
4DMLHT1W-09R4BBPH1TEHANLDwith ductless indoor unit DMLHT1G-09R4BBPH11 ton9,000 Btu/h · Non-ducted76%1.757.56,80017.0Xcel1217563442Non-ducted, up to 1.5 tons18.2

All-around best

Top 5 TEHANLD models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1DMLHT1W-09R4CBPH2TEHANLDwith ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH21 ton9,000 Btu/h · Non-ducted89%1.909.022.012.0CEE 25CEE 26Xcel1217563445Non-ducted, up to 1.5 tons49.347.651.047.6
2DMLHT1W-12R4CBPH2TEHANLDwith ductless indoor unit DMLHT1G-12R4CBPH2Also listed as DMLHT1W-12R4BBPH21 ton12,000 Btu/h · Non-ducted70%1.869.022.012.0CEE 25CEE 26Xcel1217563447Non-ducted, up to 1.5 tons40.329.651.029.6
3DMLHT1W-09R4CBPH1TEHANLDwith ductless indoor unit DMLHT1G-09R4CBPH11 ton9,000 Btu/h · Non-ducted78%1.757.517.010.2Xcel1217563441Non-ducted, up to 1.5 tons16.920.813.020.8
4DMLHT1W-09R4BBPH1TEHANLDwith ductless indoor unit DMLHT1G-09R4BBPH11 ton9,000 Btu/h · Non-ducted76%1.757.517.010.2Xcel1217563442Non-ducted, up to 1.5 tons15.618.213.018.2
5DMLHT1W-12R4BBPH1TEHANLDwith ductless indoor unit DMLHT1G-12R4BBPH1Also listed as TSAC24-0745-L120-21 ton12,000 Btu/h · Non-ducted62%1.707.517.09.8None1217563444Non-ducted, up to 1.5 tons7.44.210.6Not a pick

Best model on each rating

TEHANLD’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH21.90Non-ducted, up to 1.5 tons42%217563445
Capacity retention at 5°FDMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH289%Non-ducted, up to 1.5 tons71%217563445
HSPF2DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH29.0Non-ducted, up to 1.5 tons29%217563445
SEER2DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH222.0Non-ducted, up to 1.5 tons56%217563445
EER2DMLHT1W-09R4CBPH2Also listed as DMLHT1W-09R4BBPH212.0Non-ducted, up to 1.5 tons44%217563445
Heating capacity at 5°FDMLHT1W-12R4CBPH2Also listed as DMLHT1W-12R4BBPH28,400 Btu/hNon-ducted, up to 1.5 tons34%217563447

All 10 TEHANLD models in Explore

TEHANLD size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
TEHANLD: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons47.6(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH26 of 10 models qualify · AHRI 21756344549.3(50 is the typical model of its size class)DMLHT1W-09R4CBPH2with ductless indoor unit DMLHT1G-09R4CBPH2Also listed as DMLHT1W-09R4BBPH210 of 10 models have all five ratings · AHRI 217563445

All-around board, every manufacturer

Newest TEHANLD certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified TEHANLD outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
T-SAC24-0745-L120-2TEHANLDwith ductless indoor unit T-SAC24-0745-L120-11 ton12,000 Btu/h · Non-ducted1.7062%7.517.0None2217624101
T-SAC24-0745-S120-2TEHANLDwith ductless indoor unit T-SAC24-0745-S120-11 ton12,000 Btu/h · Non-ducted1.7062%7.517.0None2217624100
DMLHT1W-12R4BBPH2TEHANLDwith ductless indoor unit DMLHT1G-12R4BBPH21 ton12,000 Btu/h · Non-ducted1.8670%9.022.0CEE 25CEE 26Xcel1217563448
DMLHT1W-12R4CBPH2TEHANLDwith ductless indoor unit DMLHT1G-12R4CBPH21 ton12,000 Btu/h · Non-ducted1.8670%9.022.0CEE 25CEE 26Xcel1217563447
DMLHT1W-09R4BBPH2TEHANLDwith ductless indoor unit DMLHT1G-09R4BBPH21 ton9,000 Btu/h · Non-ducted1.9089%9.022.0CEE 25CEE 26Xcel1217563446

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for TEHANLD in this group.

Compare TEHANLD

Manufacturers of a similar size, side by side.

TEHANLD includes these brand names as listed in AHRI: TEHANLD. Standards are checked against published thresholds; program rules beyond ratings are not checked.