- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
12,335 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2826CP48HPINV15PUCOOLPRO | COOLPRO | 4 tons48,000 Btu/h · Ducted | 1.82 | 72% | 8.2 | 14.6 | 9.3 | 34,600 | None | 1 | 217992589 |
| 2827CP60HPINV15PUCOOLPRO | COOLPRO | 4.5 tons55,000 Btu/h · Ducted | 1.80 | 68% | 8.0 | 13.4 | 8.6 | 39,000 | None | 1 | 217992590 |
| 2828CH-ALT18HP24V-230VOCooper&Hunterwith ducted air handler CH-MP18AHU24V | Cooper&Hunter | 1.5 tons18,000 Btu/h · Ducted | 2.17 | 66% | 8.3 | 17.0 | 9.5 | 11,900 | None | 1 | 218470839 |
| 2829CH-ALT24HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP24AHU24V | Cooper&Hunter | 2 tons23,000 Btu/h · Ducted | 1.78 | 71% | 8.7 | 16.4 | 8.0 | 16,300 | ES CC | 2 | 218470841 |
| 2830CH-ALT30HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP30AHU24V | Cooper&Hunter | 2.5 tons30,000 Btu/h · Ducted | 1.98 | 71% | 9.2 | 17.6 | 9.1 | 21,200 | ES CC | 3 | 218470842 |
| 2831CH-ALT36HP24V-230VOCooper&Hunterwith ducted air handler CH-MP36AHU24V | Cooper&Hunter | 3 tons34,000 Btu/h · Ducted | 2.26 | 65% | 8.6 | 15.2 | 8.1 | 22,200 | None | 2 | 218470840 |
| 2832CH-ALT48HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP48AHU24V | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted | 1.85 | 70% | 8.2 | 15.2 | 8.0 | 33,600 | ES CC | 1 | 218470843 |
| 2833CH-ALT60HP24V-230VOCooper&Hunter · CH Serieswith ducted air handler CH-MP60AHU24V | Cooper&Hunter | 4.5 tons54,000 Btu/h · Ducted | 1.82 | 70% | 8.1 | 16.0 | 8.3 | 37,800 | ES CC | 1 | 218470844 |
| 2834CH-PQ18-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ18AHU | Cooper&Hunter | 1.5 tons18,000 Btu/h · Ducted | 2.12 | 103% | 10.1 | 19.0 | 12.5 | 18,600 | CEE 25CEE 26CEE AdvXcelDOEES CC | 8 | 215864120 |
| 2835CH-PQ24-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ24AHU | Cooper&Hunter | 2 tons24,000 Btu/h · Ducted | 2.14 | 86% | 10.0 | 18.6 | 12.0 | 20,600 | CEE 25CEE 26XcelES CC | 11 | 215864121 |
| 2836CH-PQ33-230VOCooper&Hunter · CH Serieswith ducted air handler CH-STM30AHU24V | Cooper&Hunter | 2.5 tons30,000 Btu/h · Ducted | 2.00 | 100% | 10.2 | 17.5 | 11.7 | 32,000 | CEE 25CEE 26XcelES CC | 12 | 218470847 |
| 2837CH-PQ36-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ36AHU | Cooper&Hunter | 3 tons36,000 Btu/h · Ducted | 2.06 | 91% | 10.0 | 17.7 | 12.0 | 32,600 | CEE 25CEE 26XcelES CC | 1 | 215864123 |
| 2838CH-PQ36X-230VOCooper&Hunter · CH Serieswith ducted air handler CH-ACL30-36B | Cooper&Hunter | 3 tons36,000 Btu/h · Ducted | 1.90 | 95% | 9.4 | 15.8 | 10.7 | 36,000 | CEE 25CEE 26XcelES CC | 8 | 217732885 |
| 2839CH-PQ48-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ48AHU | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted | 2.00 | 100% | 9.5 | 17.5 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 8 | 215864124 |
| 2840CH-PQ55-230VOCooper&Hunter · CH Serieswith ducted air handler CH-PQ55AHU | Cooper&Hunter | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | 12.0 | 54,000 | CEE 25CEE 26XcelES CC | 6 | 215864125 |
| 2841CH-R18MES-230VOCooper&Hunter · CH Series | Cooper&Hunter | 1.5 tons18,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.31 | 74% | 9.9 | 22.6 | 13.0 | 14,000 | CEE 25CEE 26XcelES CC | 3 | 215864256 |
| 2842CH-R28MES-230VOCooper&Hunter · CH Series | Cooper&Hunter | 2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 25.0 | 13.0 | 19,000 | CEE 25CEE 26XcelES CC | 3 | 215864257 |
| 2843CH-R36LCU-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RSH36LCCT | Cooper&Hunter | 3 tons36,000 Btu/h · Ducted and non-ducted | 2.20 | 70% | 10.3 | 20.0 | 9.6 | 26,600 | CEE 25CEE 26XcelES CC | 5 | 215864198 |
| 2844CH-R36MES-230VOCooper&Hunter · CH Series | Cooper&Hunter | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 70% | 9.5 | 24.0 | 12.0 | 26,000 | CEE 25CEE 26XcelES CC | 3 | 215864260 |
| 2845CH-R48LCU-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RSH48LCCT | Cooper&Hunter | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.00 | 76% | 9.8 | 17.1 | 10.0 | 38,000 | CEE 25CEE 26XcelES CC | 5 | 215864199 |
| 2846CH-R48MES-230VOCooper&Hunter · CH Series | Cooper&Hunter | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 81% | 10.6 | 20.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 215864264 |
| 2847CH-R60LCU-230VOCooper&Hunterwith ducted air handler CH-RS60LCDT-HS | Cooper&Hunter | 5 tons58,000 Btu/h · Ducted and non-ducted | 2.20 | 67% | 9.7 | 17.0 | 10.0 | 40,000 | CEE 25CEE 26 | 3 | 215864231 |
| 2848CH-R60MES-230VOCooper&Hunter | Cooper&Hunter | 5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.20 | 65% | 9.5 | 22.0 | 10.0 | 39,000 | CEE 25CEE 26 | 3 | 215864266 |
| 2849CH-REL30-230VOCooper&Hunter · CH Serieswith ducted air handler CH-RS30MAHU | Cooper&Hunter | 2.5 tons30,000 Btu/h · Ducted and non-ducted | 2.10 | 68% | 8.7 | 17.0 | 11.0 | 20,400 | CEE 25CEE 26 | 4 | 215864133 |
| 2850CH-REL36-230VOCooper&Hunterwith ductless indoor unit CH-R36MELVWM-230VI | Cooper&Hunter | 3 tons36,000 Btu/h · Non-ducted | 2.02 | 67% | 9.1 | 19.5 | 9.3 | 24,000 | None | 3 | 215864143 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,335 models; narrow the filters for the rest.