Skip to content

CLASSIC heat pump efficiency: 40 outdoor models compared

CLASSIC has 40 heat pump outdoor models certified with this refrigerant group, in 68 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes CLASSIC makes. CLASSIC has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
40
AHRI certifications
68
Efficiency index
41%
Typical model vs same-size, same-type peers (48 models)
Meet CEE 2025
65%
26 models

How CLASSIC compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
CLASSIC against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of CLASSIC’s own modelsCLASSIC is strongest on heating capacity at 5°F (its typical model beats 47% of comparable models) and weakest on HSPF2 (37%).
  • CLASSIC
  • Middle half of its models
  • Other ranked manufacturers
CLASSIC

Source: AHRI Directory, NEEP · as of

Average peer percentile of CLASSIC’s models
RatingBeats comparable modelsRankRaw median
Efficiency index48 models scored41%Not ranked—
COP at 5°F48 models scored37%Not ranked1.90
Capacity retention at 5°F48 models scored43%Not ranked74%
HSPF248 models scored37%Not ranked8.8
SEER248 models scored45%Not ranked19.0
EER248 models scored40%Not ranked11.2
Heating capacity at 5°F48 models scored47%Not ranked11,750 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
CLASSIC’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • CLASSIC (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons254%46%43%79%
Ducted, 2 tons461%55%55%66%
Ducted, 2.5–3 tons256%27%57%76%
Ducted, 3.5–4.5 tons470%67%73%83%
Non-ducted, up to 1.5 tons2329%29%24%30%
Non-ducted, 2 tons635%24%38%30%
Non-ducted, 2.5–3 tons541%44%40%47%
Non-ducted, 3.5–4.5 tons259%60%40%70%

Every CLASSIC model in the market

CLASSIC’s 48 models with a known size and duct type, over the shape of the whole catalog.
CLASSIC models by size and ratingColoured: CLASSIC · grey shapes: all 14,508 models · lines: catalog medians by size
  • CLASSIC models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 48 classic models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top CLASSIC models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 CLASSIC cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1GMRSHC36AS4CLASSIC · M-Series3 tons36,000 Btu/h · Non-ducted100%2.1010.036,00021.0CEE 25CEE 26CEE AdvXcelDOEES CC3217284815Non-ducted, 2.5–3 tons77.2
2OCV18HN048AClassicwith ducted air handler OCA18C006AAlso listed as OCV18HN060A4 tons47,000 Btu/h · Ducted72%2.309.234,00018.5CEE 25CEE 26Xcel1217747074Ducted, 3.5–4.5 tons72.2
3GMRSHC24AS3CLASSIC · M-Series2 tons24,000 Btu/h · Non-ducted90%2.0010.021,60021.0CEE 25CEE 26XcelES CC3217284804Non-ducted, 2 tons67.5
4GMRSHC42AS5CLASSIC · M-Series3.5 tons42,000 Btu/h · Non-ducted90%2.1010.037,80021.0CEE 25CEE 26XcelES CC3217284816Non-ducted, 3.5–4.5 tons66.5
5TMRHC42AS5Classic3.5 tons39,000 Btu/h · Ducted71%2.0010.029,80020.0CEE 25CEE 26Xcel2218787834Ducted, 3.5–4.5 tons63.6

All-around best

Top 5 CLASSIC models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1OCV18HN048AClassicwith ducted air handler OCA18C006AAlso listed as OCV18HN060A4 tons47,000 Btu/h · Ducted72%2.309.218.511.5CEE 25CEE 26Xcel1217747074Ducted, 3.5–4.5 tons72.672.273.072.2
2GMRSHC42AS5CLASSIC · M-Series3.5 tons42,000 Btu/h · Ducted86%1.908.118.012.0CEE 25CEE 26XcelES CC3217284820Ducted, 3.5–4.5 tons69.155.782.555.7
3OCV18HN024AClassicwith ducted air handler OCA18C002AAlso listed as OCV18HN036A2 tons24,000 Btu/h · Ducted79%2.158.818.512.5CEE 25CEE 26Xcel1217747068Ducted, 2 tons68.160.475.760.4
4GMRSHC42AS5CLASSIC · M-Series3.5 tons42,000 Btu/h · Non-ducted90%2.1010.021.013.0CEE 25CEE 26XcelES CC3217284816Non-ducted, 3.5–4.5 tons67.766.568.866.5
5GMRSHC24AS3CLASSIC · M-Series2 tons24,000 Btu/h · Non-ducted90%2.0010.021.013.3CEE 25CEE 26XcelES CC3217284804Non-ducted, 2 tons67.667.567.867.5

Best model on each rating

CLASSIC’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FGMRSHC36AS42.10Non-ducted, 2.5–3 tons88%217284815
Capacity retention at 5°FGMRSHC36AS4100%Non-ducted, 2.5–3 tons81%217284815
HSPF2TMRHC42AS510.0Ducted, 3.5–4.5 tons86%218787834
SEER2TMRHC18AS222.0Ducted, up to 1.5 tons97%218787831
EER2GMRSHC42AS513.0Non-ducted, 3.5–4.5 tons94%217284816
Heating capacity at 5°FGMRSHC36AS436,000 Btu/hNon-ducted, 2.5–3 tons86%217284815

All 40 CLASSIC models in Explore

CLASSIC size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
CLASSIC: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons44.0(50 is the typical model of its size class)TMRHC18AS22 of 2 models qualify · AHRI 21878783160.2(50 is the typical model of its size class)TMRHC18AS22 of 2 models have all five ratings · AHRI 218787831
Ducted, 2 tons60.4(50 is the typical model of its size class)OCV18HN024Awith ducted air handler OCA18C002AAlso listed as OCV18HN036A4 of 4 models qualify · AHRI 21774706868.1(50 is the typical model of its size class)OCV18HN024Awith ducted air handler OCA18C002AAlso listed as OCV18HN036A4 of 4 models have all five ratings · AHRI 217747068
Ducted, 2.5–3 tons52.2(50 is the typical model of its size class)GMRSHC36AS42 of 2 models qualify · AHRI 21728481959.0(50 is the typical model of its size class)GMRSHC36AS42 of 2 models have all five ratings · AHRI 217284819
Ducted, 3.5–4.5 tons72.2(50 is the typical model of its size class)OCV18HN048Awith ducted air handler OCA18C006AAlso listed as OCV18HN060A4 of 4 models qualify · AHRI 21774707472.6(50 is the typical model of its size class)OCV18HN048Awith ducted air handler OCA18C006AAlso listed as OCV18HN060A4 of 4 models have all five ratings · AHRI 217747074
Non-ducted, up to 1.5 tons61.9(50 is the typical model of its size class)TMRHC18AS216 of 23 models qualify · AHRI 21878782762.1(50 is the typical model of its size class)TMRHC18AS223 of 23 models have all five ratings · AHRI 218787827
Non-ducted, 2 tons67.5(50 is the typical model of its size class)GMRSHC24AS34 of 6 models qualify · AHRI 21728480467.6(50 is the typical model of its size class)GMRSHC24AS36 of 6 models have all five ratings · AHRI 217284804
Non-ducted, 2.5–3 tons77.2(50 is the typical model of its size class)GMRSHC36AS44 of 5 models qualify · AHRI 21728481564.5(50 is the typical model of its size class)GMRSHC36AS45 of 5 models have all five ratings · AHRI 217284815
Non-ducted, 3.5–4.5 tons66.5(50 is the typical model of its size class)GMRSHC42AS52 of 2 models qualify · AHRI 21728481667.7(50 is the typical model of its size class)GMRSHC42AS52 of 2 models have all five ratings · AHRI 217284816

All-around board, every manufacturer

Newest CLASSIC certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified CLASSIC outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
TSZRHC24ASClassicwith ductless indoor unit TMWHC24S2 tons24,000 Btu/h · Non-ducted1.8067%9.520.0CEE 25CEE 26Xcel4218787848
TSZRHC18ASClassicwith ductless indoor unit TMWHC18S1.5 tons18,000 Btu/h · Non-ducted1.8067%10.020.0None4218787847
TSZRHC12ASClassicwith ductless indoor unit TMWHC12S1 ton12,000 Btu/h · Non-ducted1.8073%10.020.0CEE 25CEE 26Xcel3218787846
TSZRHC09ASClassicwith ductless indoor unit TMWHC09S1 ton9,000 Btu/h · Non-ducted1.8080%9.521.0CEE 25CEE 26Xcel3218787845
TMRHC42AS5Classic3.5 tons39,000 Btu/h · Ducted and non-ducted2.0071%10.020.0CEE 25CEE 26Xcel2218787834

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families
  • TGM9 shared families
  • Gree2 shared families

Compare CLASSIC

Manufacturers of a similar size, side by side.

CLASSIC includes these brand names as listed in AHRI: CLASSIC. Standards are checked against published thresholds; program rules beyond ratings are not checked.