Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

12,335 models

Sorted by manufacturer and model.
Page 116 of 494
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
2876CH-RLS12MIA-115VOCooper&Hunterwith ductless indoor unit CH-RLS12MIA-115VICooper&Hunter1 ton12,000 Btu/h · Non-ducted1.8455%8.721.210.16,600None1216623803
2877CH-RLS12MIA-230VOCooper&Hunterwith ductless indoor unit CH-RLS12MIA-230VICooper&Hunter1 ton12,000 Btu/h · Non-ducted1.9167%9.121.310.88,000CEE 25CEE 261216623805
2878CH-RLS18MIA-230VOCooper&Hunterwith ductless indoor unit CH-RLS18MIA-230VICooper&Hunter1.5 tons18,000 Btu/h · Non-ducted2.1561%9.619.210.811,500CEE 251216623806
2879CH-RLS24MIA-230VOCooper&Hunter · CH Serieswith ductless indoor unit CH-RLS24MIA-230VICooper&Hunter2 tons24,000 Btu/h · Non-ducted2.1471%9.318.710.017,000CEE 25CEE 26XcelES CC1216623807
2880CH-RVHP19M-230VOCooper&Hunter · CH SeriesCooper&Hunter1.5 tons19,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0095%10.425.015.019,000CEE 25CEE 26XcelES CC3215864269
2881CH-RVHP28M-230VOCooper&Hunter · CH SeriesCooper&Hunter2.5 tons27,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.523.012.527,000CEE 25CEE 26XcelES CC3215864272
2882CH-RVHP36M-230VOCooper&Hunter · CH SeriesCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.013.036,000CEE 25CEE 26XcelES CC3215864275
2883CH-RVHP48M-230VOCooper&Hunter · CH SeriesCooper&Hunter4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0096%11.023.012.047,000CEE 25CEE 26XcelES CC3215864278
2884CH-RVHP55M-230VOCooper&Hunter · CH SeriesCooper&Hunter4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1087%10.720.011.748,000CEE 25CEE 26XcelES CC3215864282
2885CHV6-RS24URBMCooper & HunterCooper&Hunter2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.2074%9.018.212.020,000CEE 25CEE 26Xcel3217026546
2886CHV6-RS36URBMCooper & HunterCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1070%9.017.011.329,400CEE 25CEE 26Xcel3217026544
2887CHV6-RS36URBMHHCooper & HunterCooper&Hunter3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.45100%10.823.013.042,000CEE 25CEE 26CEE AdvXcelDOE3217026553
2888CHV6-RS48URBMCooper & HunterCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.1470%8.517.09.337,800CEE 25CEE 263217026545
2889CHV6-RS48URBMHHCooper & HunterCooper&Hunter4 tons48,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.40100%10.822.012.054,000CEE 25CEE 26CEE AdvXcelDOE3217026556
2890CHV6-RS60URBMHHCooper & HunterCooper&Hunter5 tons60,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.30100%11.021.511.063,000CEE 25CEE 26CEE AdvXcelDOE3217026559
2891FP10293US-12WHCOSTWAYwith ductless indoor unit FP10293US-22WHCOSTWAY1 ton12,000 Btu/h · Non-ducted2.0820%8.517.09.0—None1210727629
2892FP10302US-12WHCOSTWAYwith ductless indoor unit FP10302US-22WHCOSTWAY1 ton12,000 Btu/h · Non-ducted2.08—8.520.010.0—None1210727628
2893FP10318US-12WHCOSTWAYwith ductless indoor unit FP10318US-22WHCOSTWAY1.5 tons18,000 Btu/h · Non-ducted2.20—9.019.010.53,600None1210727630
2894FP10324US-12WHCOSTWAYwith ductless indoor unit FP10324US-22WHCOSTWAY2 tons23,000 Btu/h · Non-ducted1.98—8.318.510.54,200None1210727631
2895FP10404US-12WHCOSTWAYwith ductless indoor unit FP10404US-22WHCOSTWAY1 ton9,000 Btu/h · Non-ducted1.7623%8.517.09.9—None1212528054
2896FP10412US-12WHCOSTWAY · Q serieswith ductless indoor unit FP10412US-22WHCOSTWAY1 ton12,000 Btu/h · Non-ducted2.1567%10.021.012.08,200CEE 25CEE 261212528055
2897FP10518US-12WHCOSTWAY · Q serieswith ductless indoor unit FP10518US-22WHCOSTWAY1.5 tons17,000 Btu/h · Non-ducted2.1766%9.021.012.011,600CEE 25CEE 261212528056
2898FP10524US-12WHCOSTWAY · Q serieswith ductless indoor unit FP10524US-22WHCOSTWAY2 tons22,000 Btu/h · Non-ducted2.2724%10.021.013.05,600None1212528057
2899FP10789US-12BKCOSTWAY · H serieswith ductless indoor unit FP10789US-22BKCOSTWAY1.5 tons17,000 Btu/h · Non-ducted2.1766%9.021.012.011,600CEE 25CEE 261214826428
2900FP10789US-12WHCOSTWAY · H serieswith ductless indoor unit FP10789US-22WHCOSTWAY1.5 tons17,000 Btu/h · Non-ducted2.1766%9.021.012.011,600CEE 25CEE 261214826425

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 12,335 models; narrow the filters for the rest.