- Insights
- Manufacturers
- COMFORT MASTER
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
COMFORT MASTER heat pump efficiency: 6 outdoor models compared
COMFORT MASTER has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes COMFORT MASTER makes. COMFORT MASTER has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 6
- AHRI certifications
- 6
- Efficiency index
- 73%
- Typical model vs same-size, same-type peers (4 models)
- Meet CEE 2025
- 66.7%
- 4 models
How COMFORT MASTER compares with comparable models
- COMFORT MASTER
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index4 models scored | 73% | Not ranked | — |
| COP at 5°F6 models scored | 84% | Not ranked | 2.16 |
| Capacity retention at 5°F4 models scored | 58% | Not ranked | 79% |
| HSPF26 models scored | 50% | Not ranked | 10.0 |
| SEER26 models scored | 58% | Not ranked | 24.0 |
| EER26 models scored | 49% | Not ranked | 12.0 |
| Heating capacity at 5°F6 models scored | 42% | Not ranked | 9,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 66.7% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 66.7% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66.7% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- COMFORT MASTER (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 3 | 69% | 81% | 71% | 82% |
| Non-ducted, 2 tons | 1 | 87% | 71% | 85% | 95% |
| Non-ducted, 2.5–3 tons | 2 | — | 96% | 2% | 3% |
Every COMFORT MASTER model in the market
- COMFORT MASTER models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top COMFORT MASTER models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CMDI18K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI18K-C2-I | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 15,000 | 25.0 | CEE 25CEE 26Xcel | 1 | 217619868 | Non-ducted, up to 1.5 tons | 79.3 |
| 2CMDI24K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI24K-C2-I | 2 tons22,400 Btu/h · Non-ducted | 85% | 2.10 | 10.5 | 20,400 | 25.0 | CEE 25CEE 26Xcel | 1 | 217619869 | Non-ducted, 2 tons | 77.4 |
| 3CMDI12K-C1-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C1-I | 1 ton12,000 Btu/h · Non-ducted | 76% | 2.10 | 10.0 | 9,300 | 24.0 | CEE 25CEE 26Xcel | 1 | 217619866 | Non-ducted, up to 1.5 tons | 64.1 |
| 4CMDI12K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C2-I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 24.0 | CEE 25CEE 26Xcel | 1 | 217619867 | Non-ducted, up to 1.5 tons | 60.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1CMDI24K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI24K-C2-I | 2 tons22,400 Btu/h · Non-ducted | 85% | 2.10 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26Xcel | 1 | 217619869 | Non-ducted, 2 tons | 86.5 | 77.4 | 95.6 | 77.4 |
| 2CMDI18K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI18K-C2-I | 1.5 tons18,000 Btu/h · Non-ducted | 82% | 2.25 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26Xcel | 1 | 217619868 | Non-ducted, up to 1.5 tons | 83.0 | 79.3 | 86.7 | 79.3 |
| 3CMDI12K-C1-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C1-I | 1 ton12,000 Btu/h · Non-ducted | 76% | 2.10 | 10.0 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217619866 | Non-ducted, up to 1.5 tons | 62.8 | 64.1 | 61.5 | 64.1 |
| 4CMDI12K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C2-I | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217619867 | Non-ducted, up to 1.5 tons | 60.7 | 60.0 | 61.5 | 60.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CMBI36K-C2Also listed as CMBI36K-C2-O | 2.21 | Non-ducted, 2.5–3 tons | 96% | 214665263 |
| Capacity retention at 5°F | CMDI24K-C2-O | 85% | Non-ducted, 2 tons | 73% | 217619869 |
| HSPF2 | CMDI24K-C2-O | 10.5 | Non-ducted, 2 tons | 84% | 217619869 |
| SEER2 | CMDI24K-C2-O | 25.0 | Non-ducted, 2 tons | 95% | 217619869 |
| EER2 | CMDI24K-C2-O | 14.0 | Non-ducted, 2 tons | 96% | 217619869 |
| Heating capacity at 5°F | CMDI18K-C2-O | 15,000 Btu/h | Non-ducted, up to 1.5 tons | 86% | 217619868 |
COMFORT MASTER size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 79.3(50 is the typical model of its size class)CMDI18K-C2-Owith ductless indoor unit CMDI18K-C2-I3 of 3 models qualify · AHRI 217619868 | 83.0(50 is the typical model of its size class)CMDI18K-C2-Owith ductless indoor unit CMDI18K-C2-I3 of 3 models have all five ratings · AHRI 217619868 |
| Non-ducted, 2 tons | 77.4(50 is the typical model of its size class)CMDI24K-C2-Owith ductless indoor unit CMDI24K-C2-I1 of 1 models qualify · AHRI 217619869 | 86.5(50 is the typical model of its size class)CMDI24K-C2-Owith ductless indoor unit CMDI24K-C2-I1 of 1 models have all five ratings · AHRI 217619869 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
Newest COMFORT MASTER certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| CMBI36K-C2-OCOMFORT MASTERwith ductless indoor unit CMBI36K-C2-I | 3 tons34,000 Btu/h · Non-ducted | 2.21 | — | 8.0 | 17.0 | None | 1 | 217619883 |
| CMDI24K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI24K-C2-I | 2 tons22,400 Btu/h · Non-ducted | 2.10 | 85% | 10.5 | 25.0 | CEE 25CEE 26Xcel | 1 | 217619869 |
| CMDI18K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI18K-C2-I | 1.5 tons18,000 Btu/h · Non-ducted | 2.25 | 82% | 10.5 | 25.0 | CEE 25CEE 26Xcel | 1 | 217619868 |
| CMDI12K-C2-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C2-I | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 217619867 |
| CMDI12K-C1-OCOMFORT MASTERwith ductless indoor unit CMDI12K-C1-I | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 76% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 217619866 |
Compare COMFORT MASTER
COMFORT MASTER includes these brand names as listed in AHRI: COMFORT MASTER. Standards are checked against published thresholds; program rules beyond ratings are not checked.