Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

2,722 models

Sorted by manufacturer and model.
Page 17 of 109
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
401293VAN036**AA*BRYANT HEATING AND COOLING SYSTEMS · Evolution 23 VS Heat Pumpwith ducted air handler FE5BNBD60L*+UICarrier3 tons35,000 Btu/h · Ducted2.1075%9.522.012.525,200CEE 25CEE 26XcelES CC944215933965
40237MAHAQ33AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ36XB3Carrier3 tons33,000 Btu/h · Ducted and non-ducted2.0097%10.016.711.734,000CEE 25CEE 26XcelES CC9215318766
40337MARAQ30AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ30XB3Carrier2.5 tons30,000 Btu/h · Ducted and non-ducted2.1068%8.817.011.020,400CEE 25CEE 269215413022
40437MARAQ36AA3CARRIER · 45M Serieswith ducted air handler 45MBAAQ36XB3Carrier3 tons36,000 Btu/h · Ducted and non-ducted2.0062%7.716.08.623,000None9215413023
40537MBHAQ36AA3CARRIER · 45M Serieswith ducted air handler 45MBDAQ36XH3Carrier3 tons36,000 Btu/h · Ducted and non-ducted2.1090%11.117.812.037,600CEE 25CEE 26XcelES CC16215323844
40637MBRAQ36AA3CARRIER · 45M Serieswith ductless indoor unit 45MBCAQ36XA3Carrier3 tons36,000 Btu/h · Ducted and non-ducted2.2070%10.420.09.726,600CEE 25CEE 26XcelES CC16215323850
40737MGHAQ30EA3BRYANT · 37M SeriesCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00116%10.724.013.236,000CEE 25CEE 26XcelES CC12215357115
40837MGHAQ36EA3BRYANT · 37M SeriesCarrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.00100%10.723.113.136,000CEE 25CEE 26XcelES CC12215357118
40937MGRAQ30EA3BRYANT · 37M SeriesCarrier2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0084%10.025.013.026,000CEE 25CEE 26XcelES CC12215357151
41037MGRAQ36EA3BRYANT · 37M SeriesCarrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.0070%9.524.012.026,000CEE 25CEE 26XcelES CC12215357157
41137MHRAQ30AA3CARRIER · 45M Serieswith ductless indoor unit 45MHHAQ30XC3Carrier2.5 tons30,000 Btu/h · Non-ducted1.9467%9.022.412.020,000CEE 25CEE 264215413177
41237MHRAQ36AA3CARRIERwith ductless indoor unit 45MHHAQ36XC3Carrier3 tons36,000 Btu/h · Non-ducted2.0267%9.119.59.424,000None4215413178
41337MTRAQ36EA3CARRIER · 37M SeriesCarrier3 tons36,000 Btu/h · Non-ducted1.9070%8.518.89.525,200XcelES CC4216765585
41437MUHAQ30AA3BRYANT HEATING AND COOLING SYSTEMSwith indoor coil D(A,C,E)36A3J+TDR and furnace 82*SB36070V14Carrier2.5 tons28,600 Btu/h · Ducted2.7364%7.814.39.019,900CEE 25CEE 26XcelES CC1,649217192006
41537MUHAQ30AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith indoor coil CAA**4321AM and furnace OVLAAB048112Carrier2.5 tons31,200 Btu/h · Ducted2.0089%9.015.510.032,200CEE 25CEE 26XcelES CC2,683218474076
41637MUHAQ30AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SU*B060M17**16Carrier2.5 tons27,000 Btu/h · Ducted2.7958%8.516.09.020,800CEE 25CEE 26XcelES CC2,727217894954
41737MUHAQ36AA3CARRIERwith ducted air handler D(A,C,E)36A3J+TDRCarrier3 tons35,000 Btu/h · Ducted2.5078%8.015.210.028,400CEE 25CEE 26XcelES CC217217902903
41837MUHAQ36AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FMA5X36**ALCarrier3 tons36,200 Btu/h · Ducted1.9079%9.016.510.031,600CEE 25CEE 26XcelES CC2,745218474651
41937MUHAQ36AA3+TIC2025-0016CARRIERwith indoor coil D(A,C,E)36A3J+TDR and furnace 58SP*B135V24**22Carrier2.5 tons32,800 Btu/h · Ducted2.2466%7.815.59.025,200CEE 25CEE 26XcelES CC2,617217895097
42037MURAQ30AA3BRYANT HEATING AND COOLING SYSTEMSwith indoor coil D(A,C,E)36A3J+TDR and furnace 82*TB66135V24Carrier2.5 tons28,800 Btu/h · Ducted2.7764%7.815.29.019,800CEE 25CEE 262,602217192436
42137MURAQ30AA3+KSAIC0701230CARRIER · Crossover Heat Pumpwith ducted air handler FM(C,U)5S30**ALCarrier2.5 tons30,400 Btu/h · Ducted2.0057%8.014.59.018,700None1,583218609529
42237MURAQ36AA3CARRIERwith indoor coil D(A,C,E)37A3J+TDR and furnace 58TP*B090V17**16Carrier3 tons34,800 Btu/h · Ducted2.6269%8.514.88.025,400CEE 25CEE 26XcelES CC2,594218331534
42337VMB030HDS3-1CARRIER · 37VMB030HDS3-1Carrier2.5 tons30,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)2.03101%10.120.014.030,400CEE 25CEE 26XcelES CC3216369711
42437VMB036HDS3-1CARRIER · 37VMB036HDS3-1Carrier3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone)1.9986%10.120.013.334,200CEE 25CEE 26XcelES CC9216369712
42538INQ363A32-CCARRIERwith ductless indoor unit 40EIQ363A32-ECarrier3 tons36,000 Btu/h · Non-ducted——————None3215708470

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,722 models; narrow the filters for the rest.