- Insights
- Explore
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
New to heat pump ratings? The Simple view explains them in plain words →
ExploreData as of updated · sources
6,515 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 5226ML48HP230MUL-OMAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 75% | 10.0 | 21.3 | 11.7 | 36,000 | CEE 25CEE 26XcelES CC | 6 | 215864415 |
| 5227ML48HP230MUL-O*MAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 81% | 10.6 | 20.4 | 12.0 | 38,000 | CEE 25CEE 26XcelES CC | 3 | 216623563 |
| 5228ML48HP230MULH-OMAINLINE · ML Series | Rheem | 4 tons45,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 98% | 10.2 | 21.2 | 12.0 | 48,000 | CEE 25CEE 26XcelES CC | 6 | 215864430 |
| 5229ML48HP230MULH-O*MAINLINE · ML Series | Rheem | 4 tons47,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 96% | 11.0 | 23.0 | 12.0 | 47,000 | CEE 25CEE 26XcelES CC | 3 | 216623574 |
| 5230ML50HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML50HP230LMNTAHU-I | Rheem | 4 tons48,000 Btu/h · Ducted | 1.80 | 93% | 9.0 | 16.3 | 11.7 | 52,000 | CEE 25CEE 26XcelES CC | 2 | 215864317 |
| 5231ML55HP230MULH-OMAINLINE · ML Series | Rheem | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 6 | 215864434 |
| 5232ML55HP230MULH-O*MAINLINE · ML Series | Rheem | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26XcelES CC | 3 | 216623578 |
| 5233ML60HP230LCMH-OMAINLINE · ML Serieswith ducted air handler ML60HP230HSDUC-I | Rheem | 4.5 tons55,000 Btu/h · Ducted and non-ducted | 2.10 | 89% | 10.4 | 15.8 | 10.2 | 53,500 | XcelES CC | 6 | 215864402 |
| 5234ML60HP230LMNTH-OMAINLINE · ML Serieswith ducted air handler ML60HP230G3AHU-I | Rheem | 4.5 tons54,000 Btu/h · Ducted | 1.90 | 98% | 9.5 | 17.5 | 12.0 | 54,000 | CEE 25CEE 26XcelES CC | 12 | 216623404 |
| 5235MLP19AY24AJVCMAINLINE · Elitewith ducted air handler MLHMVY3621MEACA | Rheem | 2 tons22,800 Btu/h · Ducted | 1.90 | 86% | 8.5 | 19.0 | 12.0 | 19,500 | CEE 25CEE 26XcelES CC | 28 | 215747656 |
| 5236MLP19AY36AJVCMAINLINE · Elitewith ducted air handler MLHMVY3621MEACA | Rheem | 3 tons34,200 Btu/h · Ducted | 2.10 | 86% | 8.5 | 19.0 | 12.0 | 29,400 | CEE 25CEE 26XcelES CC | 15 | 215611117 |
| 5237MLP19AY48AJVCMAINLINE · Elitewith ducted air handler MLHMVY4821SEACA | Rheem | 4 tons45,500 Btu/h · Ducted | 2.10 | 92% | 8.5 | 19.0 | 12.0 | 42,000 | CEE 25CEE 26Xcel | 1 | 215611118 |
| 5238MLP19AY60AJVCMAINLINE · Elitewith ducted air handler MLHMVY6024SEACN | Rheem | 4.5 tons54,500 Btu/h · Ducted | 2.00 | 97% | 8.1 | 17.5 | 10.5 | 53,000 | Xcel | 2 | 215611122 |
| 5239RD16AY36AJVCRUUDwith indoor coil D(A,C,E)36D3J+TDR and furnace U97MV1155A24DHS | Rheem | 2.5 tons31,800 Btu/h · Ducted | 2.84 | 73% | 8.1 | 17.0 | 10.5 | 23,800 | CEE 25CEE 26XcelES CC | 944 | 218138360 |
| 5240RD18AY24AJVCRHEEMwith ducted air handler L(E,G)M24FJ | Rheem | 1.5 tons19,600 Btu/h · Ducted | 2.83 | 102% | 9.0 | 17.0 | 11.5 | 20,200 | CEE 25CEE 26CEE AdvXcelDOEES CC | 547 | 218029730 |
| 5241RD18AY36AJVCRHEEMwith ducted air handler C(A,C,D,E)36B3J+TDR | Rheem | 2.5 tons28,600 Btu/h · Ducted | 2.91 | 123% | 7.5 | 14.3 | 8.5 | 38,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,135 | 218796924 |
| 5242RD18AY48AJVCRHEEMwith ducted air handler D(A,C,E)60D3J+TDR | Rheem | 3 tons37,600 Btu/h · Ducted | 2.88 | 106% | 8.1 | 14.8 | 9.8 | 43,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1,022 | 218796931 |
| 5243RD18AY60AJVCRHEEMwith ducted air handler C(A,C,D,E)48D4J+TDR | Rheem | 4 tons45,000 Btu/h · Ducted | 2.82 | 96% | 7.5 | 14.3 | 8.5 | 46,500 | CEE 25CEE 26XcelES CC | 449 | 218796928 |
| 5244RP15AY18AJ2NRUUDwith ducted air handler AEN+CM24C2J+TDR | Rheem | 1.5 tons15,400 Btu/h · Ducted | 2.88 | 132% | 7.5 | 14.8 | 11.2 | 21,200 | XcelES CC | 133 | 218694590 |
| 5245RP15AY24AJ2NRUUDwith ducted air handler AEN+CM24C2J+TDR | Rheem | 1.5 tons20,600 Btu/h · Ducted | 3.05 | 127% | 7.5 | 14.8 | 11.2 | 27,400 | Xcel | 229 | 218694591 |
| 5246RP15AY30AJ2NRUUDwith ducted air handler AEN+CM36B2J+TDR | Rheem | 2 tons25,200 Btu/h · Ducted | 2.83 | 126% | 7.5 | 14.8 | 11.2 | 34,600 | Xcel | 627 | 218694592 |
| 5247RP15AY36AJ2NRHEEMwith indoor coil D(A,C,E)36D2J+TDR and furnace R98MV0855A21UP | Rheem | 2.5 tons31,000 Btu/h · Ducted | 2.92 | 120% | 7.5 | 14.8 | 8.5 | 41,000 | Xcel | 592 | 217451742 |
| 5248RP15AY42AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDR | Rheem | 3 tons37,600 Btu/h · Ducted | 3.06 | 130% | 7.5 | 15.2 | 11.7 | 50,000 | CEE 25CEE 26XcelES CC | 828 | 216438506 |
| 5249RP15AY48AJ2NRUUDwith ducted air handler AE*L+CM59A4J+TDR | Rheem | 3.5 tons43,000 Btu/h · Ducted | 3.08 | 128% | 7.8 | 15.2 | 11.7 | 56,500 | CEE 25CEE 26XcelES CC | 813 | 216438507 |
| 5250RP15AY60AJ2NRUUDwith indoor coil D(A,C,E)60D4J+TDR and furnace R801V1005A21UHN | Rheem | 4.5 tons53,000 Btu/h · Ducted | 3.05 | 115% | 7.8 | 15.2 | 11.7 | 64,000 | Xcel | 411 | 217015517 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 6,515 models; narrow the filters for the rest.