Skip to content

Explore certified heat pump models

Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.

New to heat pump ratings? The Simple view explains them in plain words →

ExploreData as of updated · sources

Filters
Clear all

Duct type: “Ducted (incl. mixed)” lists every model with a ducted or a mixed (multi-zone) certification, since a mixed system can serve ducted heads; “Ductless (incl. mixed)” every model with a ductless or a mixed one. The rankings compare mixed pairings with ductless units. Why

4,715 models

Sorted by manufacturer and model.
Page 28 of 189
# · Outdoor modelManufacturerSize · typeCOP@5°FCap. 5/47HSPF2SEER2EER2Btu/h @5°FMeetsCombosAHRI ref.
676D5CSRAH18AAKARCOAIRE · D5F Serieswith ducted air handler D5FSDAH18XHKCarrier1.5 tons17,500 Btu/h · Ducted and non-ducted2.4171%11.420.013.314,200CEE 25CEE 26XcelES CC73215324148
677D5CUHAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8680%8.516.011.715,000CEE 25CEE 26CEE AdvXcelDOEES CC1,264217906663
678D5CUHAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,684218483199
679D5CUHAH18AAK+TIC2025-0016HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,400 Btu/h · Ducted2.0483%9.016.011.016,800CEE 25CEE 26XcelES CC1,804217399865
680D5CURAH18AAKTEMPSTARwith ducted air handler D(A,C,E)30A3J+TDRCarrier1.5 tons17,700 Btu/h · Ducted2.8375%7.816.010.013,300CEE 25CEE 26Xcel2,296217906671
681D5CURAH18AAK+KSAIC0701230HEIL · Crossover Heat Pumpwith ducted air handler FM(C,U)5Z30**ALCarrier1.5 tons18,200 Btu/h · Ducted2.1061%9.017.010.511,800CEE 25CEE 262,955218609651
682D5CVRAH09AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAJCarrier1 ton9,000 Btu/h · Non-ducted1.8361%9.018.010.16,000CEE 2518215324153
683D5CVRAH09AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH09XAKCarrier1 ton9,000 Btu/h · Non-ducted2.1670%9.719.010.97,000CEE 25CEE 26XcelES CC18215324155
684D5CVRAH12AAJARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAJCarrier1 ton12,000 Btu/h · Non-ducted2.2158%9.219.08.87,000None18215324154
685D5CVRAH12AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH12XAKCarrier1 ton12,000 Btu/h · Non-ducted2.2158%8.818.08.87,000None18215324156
686D5CVRAH18AAKARCOAIRE · D5F Serieswith ductless indoor unit D5FVHAH18XAKCarrier1.5 tons17,000 Btu/h · Non-ducted2.1059%8.718.39.910,600None18215324157
687GH5SAN518**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)29JCarrier1.5 tons16,900 Btu/h · Ducted2.5255%7.515.212.09,800None1,818217229864
688GH5SAN519**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**1917AM and furnace 82*TB48070V17Carrier1.5 tons19,200 Btu/h · Ducted2.0043%8.015.513.08,400None1,321217683721
689H5H6S18*K*AAA*HEILwith indoor coil D(A,C,E)31A3J+TDR and furnace *80MS(N,L)0701716ACarrier1.5 tons16,300 Btu/h · Ducted2.5163%7.814.811.710,400None1,653218371852
690H5H6S19*K*AAA*HEIL · MAINLINE 16 SEER2 HPwith ducted air handler FM(C,U)5Z18**ALCarrier1.5 tons18,000 Btu/h · Ducted2.0043%7.815.513.08,100None1,878217687301
691N5H5S18*K*AAA*HEILwith indoor coil D(A,C,E)30B3J+TDR and furnace *80MS(N,L)0701716ACarrier1.5 tons16,400 Btu/h · Ducted2.5363%7.814.811.710,400CEE 255,645217597785
692PH5SAN518**AA*BRYANT HEATING AND COOLING SYSTEMSwith ducted air handler PE(S,T)27JCarrier1.5 tons16,600 Btu/h · Ducted2.5055%7.515.211.79,800None2,325217006631
693PH5SAN518**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FMA5X24**ALCarrier1.5 tons17,400 Btu/h · Ducted2.1046%8.015.512.58,200None235218754042
694PH5SAN519**AA*BRYANT HEATING AND COOLING SYSTEMS · 15 SEER2 HPwith indoor coil CAA**1917AM and furnace 82*TB48070V17Carrier1.5 tons19,200 Btu/h · Ducted2.0043%8.015.513.08,400None1,372217683722
695PH5SAN519**AB*WEATHERMAKER · 15 SEER2 HPwith ducted air handler FM(C,U)5Z18**ALCarrier1.5 tons18,000 Btu/h · Ducted2.0043%7.815.513.08,100None348218754080
696R5H5S18*K*AAA*HEILwith indoor coil D(A,C,E)30B3J+TDR and furnace *80MS(N,L)0701716ACarrier1.5 tons16,400 Btu/h · Ducted2.5363%7.814.811.710,400CEE 255,433217597120
697R5H5S19*K*AAA*TEMPSTARwith ducted air handler PE(S,T)29JCarrier1.5 tons16,900 Btu/h · Ducted2.5255%7.515.212.09,800None5,919217889950
698RAV-BP121AT2P-ULTOSHIBA CARRIER · RAV-BP121AT2P-ULwith ductless indoor unit RAV-HB121UTP-ULCarrier1 ton12,000 Btu/h · Ducted and non-ducted2.5184%12.026.016.010,100CEE 25CEE 26XcelES CC3216415462
699RAV-BP181AT2P-ULTOSHIBA CARRIER · RAV-BP181AT2P-ULwith ducted air handler RAV-HB181BTP-ULCarrier1.5 tons18,000 Btu/h · Ducted and non-ducted2.2178%10.017.111.714,000CEE 25CEE 26XcelES CC4216415475
700T5H6S18*K*AAA*TEMPSTAR · MAINLINE 16 SEER2 HPwith ducted air handler FMA5X18**ALCarrier1.5 tons17,400 Btu/h · Ducted2.1247%7.815.212.08,300None512214423962

Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 4,715 models; narrow the filters for the rest.