Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
5,427 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1251048-TPH-12K2V-25S-OUTDELLA · TPHwith ductless indoor unit 048-TPH-12K2V-25S-IN | Della | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 100% | 10.5 | 25.0 | 14.0 | 12,000 | CEE 25CEE 26XcelES CC | 2 | 217568638 |
| 1252048-TPH-18K2V-23S-OUTDELLA · TPHwith ductless indoor unit 048-TPH-18K2V-23S-IN | Della | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 23.5 | 12.5 | 17,800 | CEE 25CEE 26XcelES CC | 2 | 217568639 |
| 1253048-TPH-9K2V-25S-OUTDELLA · TPHwith ductless indoor unit 048-TPH-9K2V-25S-IN | Della | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 101% | 10.5 | 25.0 | 14.5 | 9,100 | CEE 25CEE 26XcelES CC | 2 | 217568636 |
| 1254048-TPH-MODU-1D3DELLA · TPH | Della | 1.5 tons20,000 Btu/h · Ducted and non-ducted | 2.00 | 99% | 10.0 | 27.0 | 15.0 | 19,800 | CEE 25CEE 26XcelES CC | 2 | 218471007 |
| 1255DMLHT1W-09R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4BBPH1 | DEMULLER | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 76% | 7.5 | 17.0 | 10.2 | 6,800 | Xcel | 1 | 216623857 |
| 1256DMLHT1W-09R4BBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4BBPH2 | DEMULLER | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 89% | 9.0 | 22.0 | 12.0 | 8,000 | CEE 25CEE 26Xcel | 1 | 216623861 |
| 1257DMLHT1W-09R4CBPH1DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH1 | DEMULLER | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 78% | 7.5 | 17.0 | 10.2 | 7,000 | Xcel | 1 | 216623856 |
| 1258DMLHT1W-09R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-09R4CBPH2 | DEMULLER | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 89% | 9.0 | 22.0 | 12.0 | 8,000 | CEE 25CEE 26Xcel | 1 | 216623860 |
| 1259DMLHT1W-12R4BBPH1DEMULLERwith ductless indoor unit DMLHT1G-12R4BBPH1 | DEMULLER | 1 ton12,000 Btu/h · Non-ducted | 1.70 | 62% | 7.5 | 17.0 | 9.8 | 7,400 | None | 1 | 216623859 |
| 1260DMLHT1W-12R4BBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4BBPH2 | DEMULLER | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 70% | 9.0 | 22.0 | 12.0 | 8,400 | CEE 25CEE 26Xcel | 1 | 216623863 |
| 1261DMLHT1W-12R4CBPH1DEMULLERwith ductless indoor unit DMLHT1G-12R4CBPH1 | DEMULLER | 1 ton12,000 Btu/h · Non-ducted | 1.70 | 62% | 7.5 | 17.0 | 9.5 | 7,400 | None | 1 | 216623858 |
| 1262DMLHT1W-12R4CBPH2DEMULLERwith ductless indoor unit DMLHT1G-12R4CBPH2 | DEMULLER | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 70% | 9.0 | 22.0 | 12.0 | 8,400 | CEE 25CEE 26Xcel | 1 | 216623862 |
| 12632DNMSHQCO12ADENALI AIRE · HiULTRAwith ductless indoor unit 2DNMSHQCW12A | DENALI AIRE | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 77% | 9.5 | 22.0 | 12.3 | 9,200 | CEE 25CEE 26XcelES CC | 2 | 216498645 |
| 12642DNMSHQCO18DENALI AIRE · HiULTRAwith ductless indoor unit 2DNMSHQCW18 | DENALI AIRE | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 100% | 10.0 | 21.0 | 13.0 | 18,000 | CEE 25CEE 26XcelES CC | 2 | 216498648 |
| 12652DNMSHQCO9ADENALI AIRE · HiULTRAwith ductless indoor unit 2DNMSHQCW9A | DENALI AIRE | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 97% | 10.0 | 23.0 | 14.1 | 8,700 | CEE 25CEE 26XcelES CC | 2 | 216498644 |
| 1266DP-MS12DA-1OUDEPLUSwith ductless indoor unit DP-MS12DA-1IN | DEPLUS | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 57% | 8.5 | 20.0 | 11.3 | 6,800 | CEE 25CEE 26 | 1 | 218612798 |
| 1267DP-MS12DA-2OUDEPLUSwith ducted air handler DP-MS12DA-2IN | DEPLUS | 1 ton12,000 Btu/h · Ducted | 2.05 | 54% | 8.5 | 20.0 | 11.4 | 6,500 | CEE 25CEE 26 | 1 | 218612797 |
| 1268DP-MS18DA-OUDEPLUSwith ductless indoor unit DP-MS18DA-IN | DEPLUS | 1.5 tons18,000 Btu/h · Non-ducted | 2.20 | 64% | 8.5 | 20.0 | 9.2 | 11,500 | None | 1 | 218612799 |
| 1269DP-MS12DA-1OUDEPLUSEwith ductless indoor unit DP-S12DA-1IN | DEPLUSE | 1 ton12,000 Btu/h · Non-ducted | 2.00 | 57% | 8.5 | 20.0 | 11.3 | 6,800 | CEE 25CEE 26 | 2 | 218338368 |
| 1270DP-MS12DA-2OUDEPLUSEwith ducted air handler DP-S12DA-2IN | DEPLUSE | 1 ton12,000 Btu/h · Ducted | 2.05 | 54% | 8.5 | 20.0 | 11.4 | 6,500 | CEE 25CEE 26 | 2 | 218338367 |
| 1271DP-MS18DA-OUDEPLUSEwith ductless indoor unit DP-MS18DA-IN | DEPLUSE | 1.5 tons18,000 Btu/h · Non-ducted | 2.20 | 64% | 8.5 | 20.0 | 9.2 | 11,500 | None | 1 | 218338369 |
| 1272MHP10Design Line | Design Line | 1 ton10,000 Btu/h · Ducted | 1.35 | 45% | 7.5 | 15.9 | 9.1 | 4,200 | None | 1 | 217626317 |
| 1273MHP11Design Line | Design Line | 1 ton10,000 Btu/h · Ducted | 1.40 | 46% | 7.0 | 16.2 | 9.7 | 4,300 | None | 1 | 217626318 |
| 1274DWA4-09KR2(US)Deye · AURORAwith ductless indoor unit DGA3-09KR2(US) | Deye | 1 ton9,000 Btu/h · Non-ducted | — | — | 10.5 | 25.0 | 14.5 | — | None | 1 | 216021337 |
| 1275DWA4-12KR2(US)Deye · AURORAwith ductless indoor unit DGA3-12KR2(US) | Deye | 1 ton12,000 Btu/h · Non-ducted | — | — | 9.7 | 22.5 | 12.6 | — | None | 1 | 216021338 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 5,427 models; narrow the filters for the rest.