- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
1,941 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1401OCVX-H24A-OOUELLET · Pacificwith ductless indoor unit OCVX-H24A-I | OUELLET | 2 tons22,000 Btu/h · Ducted and non-ducted | 1.80 | 78% | 9.0 | 23.5 | 12.0 | 18,000 | CEE 25CEE 26XcelES CC | 3 | 216623762 |
| 1402OFLX1-H24A-OOUELLET · Flexxwith ducted air handler OAHX1-H24A-I | OUELLET | 2 tons24,000 Btu/h · Ducted | 2.00 | 100% | 10.0 | 18.0 | 12.0 | 25,000 | CEE 25CEE 26XcelES CC | 1 | 216440571 |
| 1403OFRM3X1-H24A-OOUELLET · Myriad | OUELLET | 2 tons24,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.00 | 90% | 10.0 | 21.0 | 13.3 | 21,600 | CEE 25CEE 26XcelES CC | 3 | 216453529 |
| 1404ORT-H24DEMR3-M01/SE180OUTES · R32 18 Series | OUTES | 2 tons24,000 Btu/h · Ducted | 2.00 | 103% | 9.0 | 19.0 | 12.3 | 24,600 | CEE 25CEE 26XcelES CC | 1 | 218389013 |
| 1405OTD-H24SMR3-A01/SE143OUTESwith ducted air handler OAH-C24UMR3-A01/SE143 | OUTES | 2 tons22,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 11.4 | — | None | 5 | 218004884 |
| 1406OTD-H24SMR3-A11/SE143OUTESwith ducted air handler OAH-C24UMR3-A11/SE143 | OUTES | 2 tons22,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 11.4 | — | None | 2 | 218831199 |
| 1407OTD-H24SMR6-A01/SE150OUTESwith ducted air handler 26UCS(*,E,Q,R,W)*X | OUTES | 2 tons22,000 Btu/h · Ducted | 2.00 | 45% | 7.5 | 14.3 | 11.2 | 9,800 | None | 4 | 218147991 |
| 1408OTD-H36DMR3-B01/SE180OUTES · R32 18 Serieswith ducted air handler OAH-C24DMR3-A01/SE180 | OUTES | 2 tons24,000 Btu/h · Ducted | 2.15 | 79% | 9.5 | 19.0 | 13.2 | 19,000 | CEE 25CEE 26XcelES CC | 2 | 216437864 |
| 1409SL24000OOvairwith ductless indoor unit SL24000I | Ovair | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 74% | 9.5 | 23.0 | 12.0 | 18,600 | CEE 25CEE 26Xcel | 1 | 215735587 |
| 1410A24230W17821Oyluswith ductless indoor unit A24230N17821 | Oylus | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 54% | 9.5 | 17.0 | 9.5 | 12,000 | None | 1 | 217933647 |
| 1411A24230W17E11Oyluswith ductless indoor unit A24230N17E11 | Oylus | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 54% | 9.5 | 17.0 | 9.5 | 12,000 | None | 1 | 217933643 |
| 1412A24230W20822Oyluswith ductless indoor unit A24230N20822 | Oylus | 2 tons24,000 Btu/h · Non-ducted | 2.10 | 65% | 9.5 | 21.0 | 10.5 | 15,600 | CEE 25CEE 26 | 1 | 217933656 |
| 1413A24230W20E11Oyluswith ductless indoor unit A24230N20E11 | Oylus | 2 tons24,000 Btu/h · Non-ducted | 1.80 | 67% | 9.5 | 20.0 | 10.5 | 16,000 | CEE 25CEE 26 | 1 | 218085940 |
| 1414A24230W20E12Oyluswith ductless indoor unit A24230N20E12 | Oylus | 2 tons24,000 Btu/h · Non-ducted | 2.10 | 65% | 9.5 | 21.0 | 10.5 | 15,600 | CEE 25CEE 26 | 1 | 217933651 |
| 1415COPH121SOzone Spiritwith ductless indoor unit EOPH121S | Ozone Spirit | 2 tons24,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | 9.8 | — | None | 2 | 218079155 |
| 1416COPIH242AOZONE SPIRITwith ductless indoor unit EOPIH242A | Ozone Spirit | 2 tons23,000 Btu/h · Non-ducted | 1.98 | — | 8.3 | 18.5 | 10.5 | 4,200 | None | 1 | 214660276 |
| 1417COPXIH242AOZONE SPIRITwith ductless indoor unit EOPXIH242A | Ozone Spirit | 2 tons24,000 Btu/h · Non-ducted | 2.00 | 64% | 10.0 | 21.0 | 12.0 | 15,300 | CEE 25CEE 26 | 1 | 214660280 |
| 1418COPXIH242BOZONE SPIRITwith ductless indoor unit EOPXIH242B/COPXIH242B | Ozone Spirit | 2 tons23,400 Btu/h · Non-ducted | 2.28 | 53% | 8.2 | 18.1 | 11.3 | 13,000 | CEE 25CEE 26 | 1 | 218045434 |
| 1419COPXIH242SOzone Spiritwith ductless indoor unit EOPXIH242S | Ozone Spirit | 2 tons23,600 Btu/h · Non-ducted | — | — | 8.3 | 19.0 | 9.5 | — | None | 1 | 218806371 |
| 1420COSH242SOzone Spiritwith ductless indoor unit EOSH242S | Ozone Spirit | 2 tons23,600 Btu/h · Non-ducted | — | — | 8.3 | 19.0 | 9.5 | — | None | 1 | 218828125 |
| 1421EOPH121SOzone Spiritwith ductless indoor unit COPH121S | Ozone Spirit | 2 tons24,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | 9.8 | — | None | 1 | 218043721 |
| 1422CU-3Z22ABUCPANASONIC · MultiZone | Panasonic | 2 tons22,000 Btu/h · Non-ducted | 2.27 | 105% | 10.7 | 24.5 | 12.8 | 23,000 | CEE 25CEE 26CEE AdvXcelDOEES CC | 1 | 214837935 |
| 1423CU-4Z24BBUCPANASONIC · MultiZone | Panasonic | 2 tons24,000 Btu/h · Non-ducted | 2.08 | 113% | 11.4 | 24.0 | 13.5 | 27,000 | CEE 25CEE 26XcelES CC | 1 | 216441721 |
| 1424CU-HM24BAHUPanasonic · CU Serieswith ducted air handler CS-HM24BAHU | Panasonic | 2 tons23,000 Btu/h · Ducted | 1.87 | 90% | 10.0 | 18.3 | 11.7 | 21,600 | CEE 25CEE 26XcelES CC | 17 | 216505880 |
| 1425CU-M24BAHUPanasonic · CU Serieswith ducted air handler CS-HM24BAHU | Panasonic | 2 tons24,000 Btu/h · Ducted | 1.87 | 83% | 9.7 | 18.1 | 11.0 | 21,600 | CEE 25CEE 26XcelES CC | 17 | 216505875 |
Download CSV of the matching modelsAll 1,941 matching models, every page, in this order.