Skip to content

OUELLET heat pump efficiency: 23 outdoor models compared

OUELLET has 23 heat pump outdoor models certified with this refrigerant group, in 64 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes OUELLET makes. OUELLET has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
23
AHRI certifications
64
Efficiency index
63%
Typical model vs same-size, same-type peers (36 models)
Meet CEE 2025
95.7%
22 models

How OUELLET compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
OUELLET against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of OUELLET’s own modelsOUELLET is strongest on capacity retention at 5°F (its typical model beats 72% of comparable models) and weakest on COP at 5°F (45%).
  • OUELLET
  • Middle half of its models
  • Other ranked manufacturers
OUELLET

Source: AHRI Directory, NEEP · as of

Average peer percentile of OUELLET’s models
RatingBeats comparable modelsRankRaw median
Efficiency index36 models scored63%Not ranked—
COP at 5°F36 models scored45%Not ranked2.00
Capacity retention at 5°F36 models scored72%Not ranked90%
HSPF236 models scored49%Not ranked10.0
SEER236 models scored72%Not ranked21.0
EER236 models scored71%Not ranked12.0
Heating capacity at 5°F36 models scored67%Not ranked18,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
OUELLET’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • OUELLET (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, up to 1.5 tons771%50%44%90%
Ducted, 2 tons465%30%58%73%
Ducted, 2.5 to 3 tons458%38%55%69%
Ducted, 3.5 to 4.5 tons279%61%89%84%
Non-ducted, up to 1.5 tons1061%48%46%69%
Non-ducted, 2 tons460%28%46%67%
Non-ducted, 2.5 to 3 tons453%46%39%53%
Non-ducted, 3.5 to 4.5 tons168%82%40%43%

Every OUELLET model in the market

OUELLET’s 36 models with a known size and duct type, over the shape of the whole catalog.
OUELLET models by size and ratingColoured: OUELLET · grey shapes: all 15,936 models · lines: catalog medians by size
  • OUELLET models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 36 ouellet models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

OUELLET in the cold

From NEEP’s cold-climate listings: 23 OUELLET models against all 6,343 listed models.
OUELLET capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 6,343 models (46.6% of the catalog) have ratings at 47, 17 and 5°FAt 5°F a typical OUELLET model keeps 75% of its 47°F capacity; the typical listed model keeps 69%.
  • All listed models (median, middle 50% and 80%)
  • OUELLET (median, middle 50%)
Heating capacity, % of its 47°F maximum75%COP at maximum capacity2.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,343100%100%100%100%100%
All rated models, 17°F6,34364%69%74%83%91%
All rated models, 5°F6,34357%61%69%77%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F6,3432.833.243.483.66
All rated models, 17°F6,34322.132.292.422.61
All rated models, 5°F6,3431.81.8722.12.24
OUELLET: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
OUELLET, 47°F23100%100%100%100%100%
OUELLET, 17°F2375%81%86%94%97%
OUELLET, 5°F2370%72%75%83%99%
OUELLET: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
OUELLET, 47°F232.883.193.323.513.7
OUELLET, 17°F231.952.062.22.382.61
OUELLET, 5°F231.81.8122.042.1

Source: NEEP ccASHP list · as of

Top OUELLET models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 5 OUELLET cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1OARX-H09A-OOUELLET · Olympiawith ductless indoor unit OARX-H09A-I1 ton9,100 Btu/h · Non-ducted108%2.1111.211,50030.0CEE 25CEE 26CEE AdvXcelDOEES CC3216472855Non-ducted, up to 1.5 tons88.2
2OFLX1-H60A-OOUELLET · Flexxwith ducted air handler OAHX1-H60A-I4.5 tons53,000 Btu/h · Ducted100%2.1010.554,00018.2CEE 25CEE 26CEE AdvXcelDOEES CC6216440574Ducted, 3.5 to 4.5 tons85.1
3OFLX1-H48A-OOUELLET · Flexxwith ducted air handler OAHX1-H48A-I4 tons48,000 Btu/h · Ducted100%2.0010.048,00019.0CEE 25CEE 26XcelES CC1216440573Ducted, 3.5 to 4.5 tons78.9
4OFRM4X1-H36A-OOUELLET · Myriad3 tons36,000 Btu/h · Non-ducted100%2.1010.036,00021.0CEE 25CEE 26CEE AdvXcelDOEES CC3216453531Non-ducted, 2.5 to 3 tons77.8
5OFLX1-H36A-OOUELLET · Flexxwith ducted air handler OAHX1-H36A-I3 tons34,000 Btu/h · Ducted100%2.0010.034,00018.0CEE 25CEE 26XcelES CC11216440572Ducted, 2.5 to 3 tons77.3

All-around best

Top 5 OUELLET models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1OARX-H09A-OOUELLET · Olympiawith ductless indoor unit OARX-H09A-I1 ton9,100 Btu/h · Non-ducted108%2.1111.230.016.8CEE 25CEE 26CEE AdvXcelDOEES CC3216472855Non-ducted, up to 1.5 tons93.288.298.288.2
2OARX-H12A-OOUELLET · Olympiawith ductless indoor unit OARX-H12A-I1 ton12,000 Btu/h · Non-ducted100%2.0010.029.515.2CEE 25CEE 26XcelES CC3216472856Non-ducted, up to 1.5 tons85.273.596.973.5
3OCVX-H09A-OOUELLET · Pacificwith ducted air handler OFCX1-H09A-I1 ton9,100 Btu/h · Ducted90%2.149.222.014.2CEE 25CEE 26XcelES CC3217037911Ducted, up to 1.5 tons84.070.797.370.7
4OFLX1-H48A-OOUELLET · Flexxwith ducted air handler OAHX1-H48A-IAlso listed as OFLX1-H60A-O4 tons48,000 Btu/h · Ducted100%2.0010.019.011.7CEE 25CEE 26XcelES CC1216440573Ducted, 3.5 to 4.5 tons80.078.981.278.9
5OARX-H18A-OOUELLET · Olympiawith ducted air handler OFCX1-H18A-I1.5 tons18,000 Btu/h · Ducted94%1.809.424.514.0CEE 25CEE 26Xcel3217037922Ducted, up to 1.5 tons79.260.697.860.6

Best model on each rating

OUELLET’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FOFRM4X1-H36A-O2.10Non-ducted, 2.5 to 3 tons87%216453531
Capacity retention at 5°FOARX-H24A-O100%Non-ducted, 2 tons96%216498640
HSPF2OFLX1-H60A-O10.5Ducted, 3.5 to 4.5 tons91%216440574
SEER2OARX-H18A-O24.5Ducted, up to 1.5 tons100%217037922
EER2OARX-H09A-O16.8Non-ducted, up to 1.5 tons98%216472855
Heating capacity at 5°FOFLX1-H60A-O54,000 Btu/hDucted, 3.5 to 4.5 tons98%216440574

All 23 OUELLET models in Explore

OUELLET size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
OUELLET: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, up to 1.5 tons70.7(50 is the typical model of its size class)OCVX-H09A-Owith ducted air handler OFCX1-H09A-I7 of 7 models qualify · AHRI 21703791184.0(50 is the typical model of its size class)OCVX-H09A-Owith ducted air handler OFCX1-H09A-I7 of 7 models have all five ratings · AHRI 217037911
Ducted, 2 tons76.3(50 is the typical model of its size class)OFLX1-H24A-Owith ducted air handler OAHX1-H24A-I4 of 4 models qualify · AHRI 21644057172.0(50 is the typical model of its size class)OARX-H24A-Owith ducted air handler OFCX1-H24A-I4 of 4 models have all five ratings · AHRI 217037925
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)OFLX1-H36A-Owith ducted air handler OAHX1-H36A-I4 of 4 models qualify · AHRI 21644057268.5(50 is the typical model of its size class)OFLX1-H36A-Owith ducted air handler OAHX2-H36A-I4 of 4 models have all five ratings · AHRI 217154008
Ducted, 3.5 to 4.5 tons85.1(50 is the typical model of its size class)OFLX1-H60A-Owith ducted air handler OAHX1-H60A-I2 of 2 models qualify · AHRI 21644057480.0(50 is the typical model of its size class)OFLX1-H48A-Owith ducted air handler OAHX1-H48A-IAlso listed as OFLX1-H60A-O2 of 2 models have all five ratings · AHRI 216440573
Non-ducted, up to 1.5 tons88.2(50 is the typical model of its size class)OARX-H09A-Owith ductless indoor unit OARX-H09A-I10 of 10 models qualify · AHRI 21647285593.2(50 is the typical model of its size class)OARX-H09A-Owith ductless indoor unit OARX-H09A-I10 of 10 models have all five ratings · AHRI 216472855
Non-ducted, 2 tons68.5(50 is the typical model of its size class)OFRM3X1-H24A-O4 of 4 models qualify · AHRI 21645352978.8(50 is the typical model of its size class)OARX-H24A-Owith ductless indoor unit OARX-H24A-I4 of 4 models have all five ratings · AHRI 216498640
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)OFRM4X1-H36A-O4 of 4 models qualify · AHRI 21645353171.2(50 is the typical model of its size class)OFRM4X1-H30A-O4 of 4 models have all five ratings · AHRI 216453530
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)OFRM5X1-H42A-O1 of 1 models qualify · AHRI 21645353267.8(50 is the typical model of its size class)OFRM5X1-H42A-O1 of 1 models have all five ratings · AHRI 216453532

All-around board, every manufacturer

Newest OUELLET certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified OUELLET outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
OFLX1-H36A-OOUELLETwith indoor coil GCAC36F/NHA and furnace C75-2-V2.5 tons31,800 Btu/h · Ducted1.8072%8.516.0CEE 25CEE 26XcelES CC11217606243
OFLX1-H60A-OOUELLET · Flexxwith ducted air handler OAHX2-H60A-I4.5 tons53,000 Btu/h · Ducted2.10100%10.018.2CEE 25CEE 26CEE AdvXcelDOEES CC6217154010
OARX-H24A-OOUELLET · Olympiawith ducted air handler OFCX1-H24A-I2 tons22,000 Btu/h · Ducted and non-ducted1.8088%9.022.0CEE 25CEE 26XcelES CC3217037925
OARX-H18A-OOUELLET · Olympiawith ductless indoor unit OICX1-H18A-I1.5 tons18,000 Btu/h · Ducted and non-ducted1.8083%8.822.0CEE 25CEE 26XcelES CC3217037923
OCVX-H18A-OOUELLET · Pacificwith ducted air handler OFCX1-H18A-I1.5 tons18,000 Btu/h · Ducted and non-ducted1.9083%9.022.5CEE 25CEE 26XcelES CC3217037921

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for OUELLET in this group.

Compare OUELLET

Manufacturers of a similar size, side by side.

OUELLET includes these brand names as listed in AHRI: OUELLET. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter