- Insights
- Explore
Both views use the same certified data. This device remembers your choice.
Explore certified heat pump models
Filter every outdoor model in this refrigerant group. Each row’s numbers come from one representative AHRI certification (its best COP at 5°F). Sorting by a rating leaves out models without that rating.
Simple view, for homeowners: top picks by size and what each rating measures →
ExploreData as of updated · sources
2,834 models
Sorted by manufacturer and model.
| # · Outdoor model | Manufacturer | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | EER2 | Btu/h @5°F | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2426RHPXYB048ACTTHERMAL ZONE | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | — | — | 6.7 | 13.4 | 10.6 | — | None | 1 | 216014289 |
| 2427RHPXYB048ADTTHERMAL ZONE | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | — | — | 6.7 | 13.4 | 10.6 | — | None | 1 | 216014290 |
| 2428RHPXYB048AJTTHERMAL ZONE | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | 1.80 | 43% | 6.7 | 13.4 | 10.6 | 19,400 | None | 1 | 216014291 |
| 2429RHPXYC048ACTTHERMAL ZONE · RHPXYC | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | 1.44 | 40% | 7.2 | 15.2 | 11.5 | 18,000 | None | 1 | 216438540 |
| 2430RHPXYC048ADTTHERMAL ZONE · RHPXYC | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | 1.44 | 40% | 7.2 | 15.2 | 11.5 | 18,000 | None | 1 | 216438541 |
| 2431RHPXYC048AJTTHERMAL ZONE · RHPXYC | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | 1.44 | 40% | 7.2 | 15.2 | 11.5 | 18,000 | None | 1 | 216438536 |
| 2432TZID48H520ZCSTHERMAL ZONEwith indoor coil TZID60H520ZACD and furnace MGV96U120D5C | THERMAL ZONE | 4 tons45,000 Btu/h · Ducted | 1.90 | 89% | 9.1 | 15.0 | 9.8 | 41,000 | CEE 25CEE 26XcelES CC | 48 | 218782171 |
| 2433TZID60H520ZCThermal Zone · TZID60H520ZCwith ducted air handler TZID48H520ZA | THERMAL ZONE | 4 tons47,500 Btu/h · Ducted | 2.10 | 71% | 9.0 | 17.5 | 11.3 | 34,200 | CEE 25CEE 26XcelES CC | 3 | 217589556 |
| 2434TZID60H520ZCSTHERMAL ZONEwith indoor coil TZID24H520ZACC and furnace MGV96U100C5C | THERMAL ZONE | 4.5 tons52,000 Btu/h · Ducted | 1.90 | 83% | 8.6 | 14.9 | 8.5 | 40,000 | ES CC | 46 | 218079702 |
| 2435TZP14AY42AD2NTHERMAL ZONEwith ducted air handler TZHDYTST4821*NAN | THERMAL ZONE | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 217462487 |
| 2436TZP14AY48AD2NTHERMAL ZONEwith ducted air handler TZHDYTST4824*NAN | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | — | — | 7.8 | 14.3 | 9.0 | — | None | 1 | 218806288 |
| 2437TZP14AY48AJ2NTHERMAL ZONEwith ducted air handler AE*L+CM59A4J+TDR | THERMAL ZONE | 3.5 tons43,000 Btu/h · Ducted | 2.44 | 60% | 7.5 | 14.3 | 9.0 | 26,600 | None | 75 | 218362581 |
| 2438TZP14AY60AC2NTHERMAL ZONEwith ducted air handler TZHDYTST6021*NAA | THERMAL ZONE | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 217530427 |
| 2439TZP14AY60AD2NTHERMAL ZONEwith ducted air handler TZHDYTST6021*NAA | THERMAL ZONE | 4.5 tons55,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 217530426 |
| 2440TZP14AY60AJ2NTHERMAL ZONEwith ducted air handler AE*L+CM60B4J+TDR | THERMAL ZONE | 4.5 tons51,500 Btu/h · Ducted | 2.49 | 61% | 7.5 | 14.3 | 9.0 | 33,200 | None | 60 | 218362582 |
| 2441TZP15AY42AC2NTHERMAL ZONEwith ducted air handler TZHDYTST4821*NAN | THERMAL ZONE | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687725 |
| 2442TZP15AY42AD2NTHERMAL ZONEwith ducted air handler TZHDYTST4821*NAN | THERMAL ZONE | 3.5 tons40,000 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687726 |
| 2443TZP15AY42AJ2NTHERMAL ZONEwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | THERMAL ZONE | 3.5 tons39,000 Btu/h · Ducted | 2.20 | 51% | 7.8 | 15.2 | 11.7 | 19,800 | CEE 25ES CC | 67 | 217014484 |
| 2444TZP15AY48AC2NTHERMAL ZONEwith ducted air handler TZHDYTST4821*NAN | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687727 |
| 2445TZP15AY48AD2NTHERMAL ZONEwith ducted air handler TZHDYTST4821*NAN | THERMAL ZONE | 4 tons45,500 Btu/h · Ducted | — | — | 7.5 | 14.3 | 9.0 | — | None | 1 | 216687728 |
| 2446TZP15AY48AJ2NTHERMAL ZONEwith ducted air handler 98-888+TXV+RDS+TDR+E30B5D | THERMAL ZONE | 4 tons45,000 Btu/h · Ducted | 2.30 | 53% | 7.8 | 15.2 | 11.7 | 23,800 | None | 67 | 217014483 |
| 2447TZP15AY60AJ2NTHERMAL ZONEwith ducted air handler 98-8812+TXV+RDS+TDR+E30B6D | THERMAL ZONE | 4.5 tons52,000 Btu/h · Ducted | 2.12 | 52% | 7.8 | 15.2 | 11.7 | 27,400 | None | 51 | 217014482 |
| 2448T7C20S-H248-CTHERMOCORE SYSTEMS · T7 Serieswith ductless indoor unit T7C20S-H248-EC | THERMOCORE SYSTEMS | 4 tons48,000 Btu/h · Ducted and non-ducted | 2.11 | 81% | 9.9 | 19.0 | 9.5 | 40,500 | CEE 25CEE 26Xcel | 4 | 218003234 |
| 2449T7HH22X-H272-CTHERMOCORE SYSTEMS · T7 Series | THERMOCORE SYSTEMS | 4.5 tons53,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 2.10 | 87% | 10.7 | 20.0 | 11.7 | 48,000 | CEE 25CEE 26Xcel | 3 | 218003255 |
| 2450TMFS48HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS48IDI2NAJ0H26 | THERMOFLUX | 4 tons48,000 Btu/h · Ducted | 1.85 | 100% | 9.5 | 18.0 | 11.0 | 48,000 | CEE 25CEE 26XcelES CC | 1 | 218788000 |
Download CSV of the matching modelsAll pages in this order, up to the first 2,000 of 2,834 models; narrow the filters for the rest.