- Insights
- Manufacturers
- THERMOFLUX
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
THERMOFLUX heat pump efficiency: 9 outdoor models compared
THERMOFLUX has 9 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes THERMOFLUX makes. THERMOFLUX has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 9
- AHRI certifications
- 9
- Efficiency index
- 43%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 44.4%
- 4 models
How THERMOFLUX compares with comparable models
- THERMOFLUX
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 43% | Not ranked | — |
| COP at 5°F9 models scored | 25% | Not ranked | 1.80 |
| Capacity retention at 5°F9 models scored | 66% | Not ranked | 75% |
| HSPF29 models scored | 61% | Not ranked | 8.1 |
| SEER29 models scored | 50% | Not ranked | 15.2 |
| EER29 models scored | 22% | Not ranked | 10.0 |
| Heating capacity at 5°F9 models scored | 67% | Not ranked | 36,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 44.4% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 44.4% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 44.4% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 44.4% | 4 |
Sizes and duct types offered
- THERMOFLUX (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 2 | 47% | 25% | 60% | 52% |
| Ducted, 2.5–3 tons | 3 | 37% | 22% | 57% | 45% |
| Ducted, 3.5–4.5 tons | 4 | 46% | 27% | 65% | 52% |
Every THERMOFLUX model in the market
- THERMOFLUX models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top THERMOFLUX models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TMFS48HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS48IDI2NAJ0H26 | 4 tons48,000 Btu/h · Ducted | 100% | 1.85 | 9.5 | 48,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218788000 | Ducted, 3.5–4.5 tons | 69.4 |
| 2TMFS24HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS24IDI2NAJ0H26 | 2 tons24,000 Btu/h · Ducted | 100% | 1.85 | 10.0 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 218787998 | Ducted, 2 tons | 68.9 |
| 3TMFS55HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS55IDI2NAJ0H26 | 4.5 tons54,000 Btu/h · Ducted | 93% | 1.85 | 9.5 | 50,000 | 17.0 | CEE 25CEE 26XcelES CC | 1 | 218788001 | Ducted, 3.5–4.5 tons | 66.4 |
| 4TMFS36HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS36IDI2NAJ0H26 | 3 tons36,000 Btu/h · Ducted | 100% | 1.85 | 9.5 | 36,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218787999 | Ducted, 2.5–3 tons | 64.5 |
| 5TMFT48TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT48IDI2NAF2H26 | 4 tons48,000 Btu/h · Ducted | 75% | 1.80 | 8.1 | 36,000 | 15.2 | None | 1 | 218788004 | Ducted, 3.5–4.5 tons | 44.1 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TMFS24HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS24IDI2NAJ0H26 | 2 tons24,000 Btu/h · Ducted | 100% | 1.85 | 10.0 | 19.0 | 12.0 | CEE 25CEE 26XcelES CC | 1 | 218787998 | Ducted, 2 tons | 70.0 | 68.9 | 71.1 | 68.9 |
| 2TMFS48HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS48IDI2NAJ0H26 | 4 tons48,000 Btu/h · Ducted | 100% | 1.85 | 9.5 | 18.0 | 11.0 | CEE 25CEE 26XcelES CC | 1 | 218788000 | Ducted, 3.5–4.5 tons | 65.0 | 69.4 | 60.6 | 69.4 |
| 3TMFS36HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS36IDI2NAJ0H26 | 3 tons36,000 Btu/h · Ducted | 100% | 1.85 | 9.5 | 18.0 | 11.0 | CEE 25CEE 26XcelES CC | 1 | 218787999 | Ducted, 2.5–3 tons | 57.9 | 64.5 | 51.3 | 64.5 |
| 4TMFS55HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS55IDI2NAJ0H26 | 4.5 tons54,000 Btu/h · Ducted | 93% | 1.85 | 9.5 | 17.0 | 10.0 | CEE 25CEE 26XcelES CC | 1 | 218788001 | Ducted, 3.5–4.5 tons | 54.9 | 66.4 | 43.5 | 66.4 |
| 5TMFT48TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT48IDI2NAF2H26 | 4 tons48,000 Btu/h · Ducted | 75% | 1.80 | 8.1 | 15.2 | 9.0 | None | 1 | 218788004 | Ducted, 3.5–4.5 tons | 34.5 | 44.1 | 24.9 | 44.1 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TMFS48HDI2NAJ0H26 | 1.85 | Ducted, 3.5–4.5 tons | 32% | 218788000 |
| Capacity retention at 5°F | TMFS48HDI2NAJ0H26 | 100% | Ducted, 3.5–4.5 tons | 94% | 218788000 |
| HSPF2 | TMFS24HDI2NAJ0H26 | 10.0 | Ducted, 2 tons | 81% | 218787998 |
| SEER2 | TMFS48HDI2NAJ0H26 | 18.0 | Ducted, 3.5–4.5 tons | 76% | 218788000 |
| EER2 | TMFS24HDI2NAJ0H26 | 12.0 | Ducted, 2 tons | 60% | 218787998 |
| Heating capacity at 5°F | TMFS55HDI2NAJ0H26 | 50,000 Btu/h | Ducted, 3.5–4.5 tons | 91% | 218788001 |
THERMOFLUX size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 68.9(50 is the typical model of its size class)TMFS24HDI2NAJ0H26with ducted air handler TMFS24IDI2NAJ0H261 of 2 models qualify · AHRI 218787998 | 70.0(50 is the typical model of its size class)TMFS24HDI2NAJ0H26with ducted air handler TMFS24IDI2NAJ0H262 of 2 models have all five ratings · AHRI 218787998 |
| Ducted, 2.5–3 tons | 64.5(50 is the typical model of its size class)TMFS36HDI2NAJ0H26with ducted air handler TMFS36IDI2NAJ0H261 of 3 models qualify · AHRI 218787999 | 57.9(50 is the typical model of its size class)TMFS36HDI2NAJ0H26with ducted air handler TMFS36IDI2NAJ0H263 of 3 models have all five ratings · AHRI 218787999 |
| Ducted, 3.5–4.5 tons | 69.4(50 is the typical model of its size class)TMFS48HDI2NAJ0H26with ducted air handler TMFS48IDI2NAJ0H264 of 4 models qualify · AHRI 218788000 | 65.0(50 is the typical model of its size class)TMFS48HDI2NAJ0H26with ducted air handler TMFS48IDI2NAJ0H264 of 4 models have all five ratings · AHRI 218788000 |
Newest THERMOFLUX certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TMFT36TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT36IDI2NAF2H26 | 3 tons36,000 Btu/h · Ducted | 1.80 | 64% | 8.1 | 15.2 | None | 1 | 218806025 |
| TMFT55TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT55IDI2NAF2H26 | 4.5 tons54,000 Btu/h · Ducted | 1.80 | 74% | 8.1 | 14.3 | None | 1 | 218788005 |
| TMFT48TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT48IDI2NAF2H26 | 4 tons48,000 Btu/h · Ducted | 1.80 | 75% | 8.1 | 15.2 | None | 1 | 218788004 |
| THH36TDI2NAF2H26THERMOFLUXwith ducted air handler THH36IDI2NAF2H26 | 3 tons36,000 Btu/h · Ducted | 1.80 | 64% | 8.1 | 15.2 | None | 1 | 218788003 |
| TMFT24TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT24IDI2NAF2H26 | 2 tons24,000 Btu/h · Ducted | 1.80 | 67% | 8.1 | 15.2 | None | 1 | 218788002 |
Compare THERMOFLUX
THERMOFLUX includes these brand names as listed in AHRI: THERMOFLUX. Standards are checked against published thresholds; program rules beyond ratings are not checked.