- Insights
- Manufacturers
- THERMOFLUX
Both views use the same certified data. This device remembers your choice.
THERMOFLUX heat pump efficiency: 21 outdoor models compared
THERMOFLUX has 21 heat pump outdoor models certified with this refrigerant group, in 21 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes THERMOFLUX makes. THERMOFLUX has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 21
- AHRI certifications
- 21
- Efficiency index
- 61%
- Typical model vs same-size, same-type peers (21 models)
- Meet CEE 2025
- 76.2%
- 16 models
How THERMOFLUX compares with comparable models
- THERMOFLUX
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index21 models scored | 61% | Not ranked | — |
| COP at 5°F21 models scored | 33% | Not ranked | 1.85 |
| Capacity retention at 5°F21 models scored | 73% | Not ranked | 93% |
| HSPF221 models scored | 64% | Not ranked | 10.0 |
| SEER221 models scored | 74% | Not ranked | 23.5 |
| EER221 models scored | 58% | Not ranked | 12.3 |
| Heating capacity at 5°F21 models scored | 70% | Not ranked | 26,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 76.2% | 16 |
| CEE 2026 Tier 1 (Split ASHP) | 76.2% | 16 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 76.2% | 16 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 57.1% | 12 |
Sizes and duct types offered
- THERMOFLUX (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 2 | 47% | 25% | 60% | 51% |
| Ducted, 2.5 to 3 tons | 3 | 37% | 21% | 56% | 45% |
| Ducted, 3.5 to 4.5 tons | 4 | 46% | 27% | 65% | 52% |
| Non-ducted, up to 1.5 tons | 5 | 77% | 38% | 73% | 90% |
| Non-ducted, 2 tons | 1 | 59% | 16% | 72% | 72% |
| Non-ducted, 2.5 to 3 tons | 4 | 80% | 53% | 70% | 98% |
| Non-ducted, 3.5 to 4.5 tons | 2 | 69% | 29% | 40% | 97% |
Every THERMOFLUX model in the market
- THERMOFLUX models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top THERMOFLUX models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TMFX18HEI2NAS0U25THERMOFLUX · High heat free matchAlso listed as TMFX18HEI2NAS0U25 | 1.5 tons20,000 Btu/h · Non-ducted | 99% | 2.00 | 10.0 | 19,800 | 27.0 | CEE 25CEE 26XcelES CC | 1 | 218082704 | Non-ducted, up to 1.5 tons | 72.4 |
| 2TMFS48HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS48IDI2NAJ0H26 | 4 tons48,000 Btu/h · Ducted | 100% | 1.85 | 9.5 | 48,000 | 18.0 | CEE 25CEE 26XcelES CC | 1 | 218788000 | Ducted, 3.5 to 4.5 tons | 69.4 |
| 3TMFS24HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS24IDI2NAJ0H26 | 2 tons24,000 Btu/h · Ducted | 100% | 1.85 | 10.0 | 24,000 | 19.0 | CEE 25CEE 26XcelES CC | 1 | 218787998 | Ducted, 2 tons | 68.8 |
| 4TMFX27HEI2NAS0U25THERMOFLUX · High heat free matchAlso listed as TMFX27HEI2NAS0U25 | 2.5 tons27,000 Btu/h · Non-ducted | 96% | 2.00 | 10.5 | 26,000 | 26.5 | CEE 25CEE 26XcelES CC | 1 | 218082705 | Non-ducted, 2.5 to 3 tons | 68.7 |
| 5TMFS55HDI2NAJ0H26THERMOFLUX · Heat Seriewith ducted air handler TMFS55IDI2NAJ0H26 | 4.5 tons54,000 Btu/h · Ducted | 93% | 1.85 | 9.5 | 50,000 | 17.0 | CEE 25CEE 26XcelES CC | 1 | 218788001 | Ducted, 3.5 to 4.5 tons | 66.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1TMFX18HEI2NAS0U25THERMOFLUX · High heat free matchAlso listed as TMFX18HEI2NAS0U25 | 1.5 tons20,000 Btu/h · Non-ducted | 99% | 2.00 | 10.0 | 27.0 | 15.0 | CEE 25CEE 26XcelES CC | 1 | 218082704 | Non-ducted, up to 1.5 tons | 83.7 | 72.4 | 94.9 | 72.4 |
| 2TMFX27HEI2NAS0U25THERMOFLUX · High heat free matchAlso listed as TMFX27HEI2NAS0U25 | 2.5 tons27,000 Btu/h · Non-ducted | 96% | 2.00 | 10.5 | 26.5 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218082705 | Non-ducted, 2.5 to 3 tons | 83.4 | 68.7 | 98.1 | 68.7 |
| 3TMF09HEI2NAO0T24THERMOFLUX · High heat splitwith ductless indoor unit TMF09HEI2NAO0T24-IN | 1 ton9,000 Btu/h · Non-ducted | 106% | 1.80 | 10.5 | 25.0 | 14.5 | CEE 25CEE 26XcelES CC | 1 | 218082700 | Non-ducted, up to 1.5 tons | 77.3 | 64.9 | 89.7 | 64.9 |
| 4TMFX36HEI2NAS0U25THERMOFLUX · High heat free matchAlso listed as TMFX36HEI2NAS0U25 | 3 tons36,000 Btu/h · Non-ducted | 83% | 2.00 | 10.0 | 25.0 | 13.6 | CEE 25CEE 26XcelES CC | 1 | 218082706 | Non-ducted, 2.5 to 3 tons | 76.9 | 58.6 | 95.1 | 58.6 |
| 5TMF12HEI2NAM0T24THERMOFLUX · High heat splitwith ductless indoor unit TMF12HEI2NAM0T24-IN | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218082701 | Non-ducted, up to 1.5 tons | 75.6 | 63.4 | 87.9 | 63.4 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | TMFX18HEI2NAS0U25Also listed as TMFX18HEI2NAS0U25 | 2.00 | Non-ducted, up to 1.5 tons | 64% | 218082704 |
| Capacity retention at 5°F | TMFS48HDI2NAJ0H26 | 100% | Ducted, 3.5 to 4.5 tons | 94% | 218788000 |
| HSPF2 | TMF09HEI2NAO0T24 | 10.5 | Non-ducted, up to 1.5 tons | 81% | 218082700 |
| SEER2 | TMFX27HEI2NAS0U25Also listed as TMFX27HEI2NAS0U25 | 26.5 | Non-ducted, 2.5 to 3 tons | 99% | 218082705 |
| EER2 | TMFX27HEI2NAS0U25Also listed as TMFX27HEI2NAS0U25 | 14.0 | Non-ducted, 2.5 to 3 tons | 97% | 218082705 |
| Heating capacity at 5°F | TMFX18HEI2NAS0U25Also listed as TMFX18HEI2NAS0U25 | 19,800 Btu/h | Non-ducted, up to 1.5 tons | 98% | 218082704 |
THERMOFLUX size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 68.8(50 is the typical model of its size class)TMFS24HDI2NAJ0H26with ducted air handler TMFS24IDI2NAJ0H261 of 2 models qualify · AHRI 218787998 | 70.1(50 is the typical model of its size class)TMFS24HDI2NAJ0H26with ducted air handler TMFS24IDI2NAJ0H262 of 2 models have all five ratings · AHRI 218787998 |
| Ducted, 2.5 to 3 tons | 64.2(50 is the typical model of its size class)TMFS36HDI2NAJ0H26with ducted air handler TMFS36IDI2NAJ0H261 of 3 models qualify · AHRI 218787999 | 58.0(50 is the typical model of its size class)TMFS36HDI2NAJ0H26with ducted air handler TMFS36IDI2NAJ0H263 of 3 models have all five ratings · AHRI 218787999 |
| Ducted, 3.5 to 4.5 tons | 69.4(50 is the typical model of its size class)TMFS48HDI2NAJ0H26with ducted air handler TMFS48IDI2NAJ0H264 of 4 models qualify · AHRI 218788000 | 65.4(50 is the typical model of its size class)TMFS48HDI2NAJ0H26with ducted air handler TMFS48IDI2NAJ0H264 of 4 models have all five ratings · AHRI 218788000 |
| Non-ducted, up to 1.5 tons | 72.4(50 is the typical model of its size class)TMFX18HEI2NAS0U25Also listed as TMFX18HEI2NAS0U255 of 5 models qualify · AHRI 218082704 | 83.7(50 is the typical model of its size class)TMFX18HEI2NAS0U25Also listed as TMFX18HEI2NAS0U255 of 5 models have all five ratings · AHRI 218082704 |
| Non-ducted, 2 tons | 59.1(50 is the typical model of its size class)TMF24HEI2NAK0T24with ductless indoor unit TMF24HEI2NAK0T24-IN1 of 1 models qualify · AHRI 218082703 | 58.5(50 is the typical model of its size class)TMF24HEI2NAK0T24with ductless indoor unit TMF24HEI2NAK0T24-IN1 of 1 models have all five ratings · AHRI 218082703 |
| Non-ducted, 2.5 to 3 tons | 68.7(50 is the typical model of its size class)TMFX27HEI2NAS0U25Also listed as TMFX27HEI2NAS0U254 of 4 models qualify · AHRI 218082705 | 83.4(50 is the typical model of its size class)TMFX27HEI2NAS0U25Also listed as TMFX27HEI2NAS0U254 of 4 models have all five ratings · AHRI 218082705 |
| Non-ducted, 3.5 to 4.5 tons | 48.5(50 is the typical model of its size class)TMFX48HEI2NAS0U252 of 2 models qualify · AHRI 218082707 | 70.2(50 is the typical model of its size class)TMFX48HEI2NAS0U252 of 2 models have all five ratings · AHRI 218082707 |
Newest THERMOFLUX certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| TMFX48HEI2NAS0U25*THERMOFLUX · High heat free match | 4 tons48,000 Btu/h · Non-ducted | 1.97 | 88% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 218869104 |
| TMFX36HEI2NAS0U25*THERMOFLUX · High heat free match | 3 tons36,000 Btu/h · Non-ducted | 2.00 | 83% | 10.0 | 25.0 | CEE 25CEE 26Xcel | 1 | 218869103 |
| TMFX27HEI2NAS0U25*THERMOFLUX · High heat free match | 2.5 tons27,000 Btu/h · Non-ducted | 2.00 | 96% | 10.5 | 26.5 | CEE 25CEE 26Xcel | 1 | 218869102 |
| TMFX18HEI2NAS0U25*THERMOFLUX · High heat free match | 1.5 tons20,000 Btu/h · Non-ducted | 2.00 | 99% | 10.0 | 27.0 | CEE 25CEE 26Xcel | 1 | 218869101 |
| TMFT36TDI2NAF2H26THERMOFLUXwith ducted air handler TMFT36IDI2NAF2H26 | 3 tons36,000 Btu/h · Ducted | 1.80 | 64% | 8.1 | 15.2 | None | 1 | 218806025 |
Compare THERMOFLUX
THERMOFLUX includes these brand names as listed in AHRI: THERMOFLUX. Standards are checked against published thresholds; program rules beyond ratings are not checked.