Skip to content

AOKOL heat pump efficiency: 4 outdoor models compared

AOKOL has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes AOKOL makes. AOKOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
58%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How AOKOL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
AOKOL against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of AOKOL’s own modelsAOKOL is strongest on SEER2 (its typical model beats 77% of comparable models) and weakest on heating capacity at 5°F (39%).
  • AOKOL
  • Middle half of its models
  • Other ranked manufacturers
AOKOL

Source: AHRI Directory, NEEP · as of

Average peer percentile of AOKOL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored58%Not ranked—
COP at 5°F4 models scored52%Not ranked2.00
Capacity retention at 5°F4 models scored41%Not ranked72%
HSPF24 models scored65%Not ranked10.3
SEER24 models scored77%Not ranked23.3
EER24 models scored49%Not ranked11.6
Heating capacity at 5°F4 models scored39%Not ranked22,900 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
AOKOL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • AOKOL (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons172%63%81%79%
Non-ducted, 2.5–3 tons258%53%70%79%
Non-ducted, 3.5–4.5 tons142%37%40%73%

Every AOKOL model in the market

AOKOL’s 4 models with a known size and duct type, over the shape of the whole catalog.
AOKOL models by size and ratingColoured: AOKOL · grey shapes: all 14,508 models · lines: catalog medians by size
  • AOKOL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 aokol models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top AOKOL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 AOKOL cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1AOODU-1D2SAOKOL1.5 tons18,000 Btu/h · Non-ducted80%2.0010.516,00024.0CEE 25CEE 26XcelES CC1217496788Non-ducted, up to 1.5 tons68.6
2AOODU-1D3SAOKOL2.5 tons27,000 Btu/h · Non-ducted71%2.0010.519,80024.0CEE 25CEE 26XcelES CC1217496789Non-ducted, 2.5–3 tons57.5
3AOODU-1D4SAOKOL3 tons35,000 Btu/h · Non-ducted72%2.0010.026,00022.5CEE 25CEE 26XcelES CC1217496790Non-ducted, 2.5–3 tons52.5
4AOODU-1D5SAOKOL3.5 tons42,000 Btu/h · Non-ducted71%2.0010.030,00022.0CEE 25CEE 26XcelES CC1217496791Non-ducted, 3.5–4.5 tons31.2

All-around best

Top 4 AOKOL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1AOODU-1D2SAOKOL1.5 tons18,000 Btu/h · Non-ducted80%2.0010.524.013.0CEE 25CEE 26XcelES CC1217496788Non-ducted, up to 1.5 tons72.268.675.868.6
2AOODU-1D3SAOKOL2.5 tons27,000 Btu/h · Non-ducted71%2.0010.524.012.0CEE 25CEE 26XcelES CC1217496789Non-ducted, 2.5–3 tons65.157.572.657.5
3AOODU-1D4SAOKOL3 tons35,000 Btu/h · Non-ducted72%2.0010.022.511.1CEE 25CEE 26XcelES CC1217496790Non-ducted, 2.5–3 tons51.152.549.752.5
4AOODU-1D5SAOKOL3.5 tons42,000 Btu/h · Non-ducted71%2.0010.022.011.2CEE 25CEE 26XcelES CC1217496791Non-ducted, 3.5–4.5 tons42.431.253.731.2

Best model on each rating

AOKOL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FAOODU-1D2S2.00Non-ducted, up to 1.5 tons63%217496788
Capacity retention at 5°FAOODU-1D2S80%Non-ducted, up to 1.5 tons61%217496788
HSPF2AOODU-1D3S10.5Non-ducted, 2.5–3 tons80%217496789
SEER2AOODU-1D3S24.0Non-ducted, 2.5–3 tons91%217496789
EER2AOODU-1D2S13.0Non-ducted, up to 1.5 tons70%217496788
Heating capacity at 5°FAOODU-1D2S16,000 Btu/hNon-ducted, up to 1.5 tons88%217496788

All 4 AOKOL models in Explore

AOKOL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
AOKOL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons68.6(50 is the typical model of its size class)AOODU-1D2S1 of 1 models qualify · AHRI 21749678872.2(50 is the typical model of its size class)AOODU-1D2S1 of 1 models have all five ratings · AHRI 217496788
Non-ducted, 2.5–3 tons57.5(50 is the typical model of its size class)AOODU-1D3S2 of 2 models qualify · AHRI 21749678965.1(50 is the typical model of its size class)AOODU-1D3S2 of 2 models have all five ratings · AHRI 217496789
Non-ducted, 3.5–4.5 tons31.2(50 is the typical model of its size class)AOODU-1D5S1 of 1 models qualify · AHRI 21749679142.4(50 is the typical model of its size class)AOODU-1D5S1 of 1 models have all five ratings · AHRI 217496791

All-around board, every manufacturer

Newest AOKOL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified AOKOL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
AOODU-1D5SAOKOL3.5 tons42,000 Btu/h · Non-ducted2.0071%10.022.0CEE 25CEE 26XcelES CC1217496791
AOODU-1D4SAOKOL3 tons35,000 Btu/h · Non-ducted2.0072%10.022.5CEE 25CEE 26XcelES CC1217496790
AOODU-1D3SAOKOL2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26XcelES CC1217496789
AOODU-1D2SAOKOL1.5 tons18,000 Btu/h · Non-ducted2.0080%10.524.0CEE 25CEE 26XcelES CC1217496788

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for AOKOL in this group.

Compare AOKOL

Manufacturers of a similar size, side by side.

AOKOL includes these brand names as listed in AHRI: AOKOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.