Skip to content

CASI0 heat pump efficiency: 5 outdoor models compared

CASI0 has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes CASI0 makes. CASI0 has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
5
Efficiency index
—
No model has all five ratings
Meet CEE 2025
0%
0 models

How CASI0 compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
CASI0 against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of CASI0’s own modelsCASI0 is strongest on EER2 (its typical model beats 11% of comparable models) and weakest on HSPF2 (2%).
  • CASI0
  • Middle half of its models
  • Other ranked manufacturers
CASI0

Source: AHRI Directory, NEEP · as of

Average peer percentile of CASI0’s models
RatingBeats comparable modelsRankRaw median
Efficiency index0 models scored—Not ranked—
COP at 5°F0 models scored—Not ranked—
Capacity retention at 5°F0 models scored—Not ranked—
HSPF25 models scored2%Not ranked8.0
SEER25 models scored6%Not ranked17.0
EER25 models scored11%Not ranked9.7
Heating capacity at 5°F0 models scored—Not ranked—

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
CASI0’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • CASI0 (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons3——2%8%
Non-ducted, 2 tons1——1%4%
Non-ducted, 2.5–3 tons1——2%3%

Every CASI0 model in the market

CASI0’s 5 models with a known size and duct type, over the shape of the whole catalog.
CASI0 models by size and ratingColoured: CASI0 · grey shapes: all 14,508 models · lines: catalog medians by size
  • CASI0 models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 casi0 models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8651.701.802.002.102.46
Ducted, 4 tons7261.801.862.002.122.41
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top CASI0 models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No CASI0 model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

No CASI0 model has all five all-around ratings.

Best model on each rating

CASI0’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°F—————
Capacity retention at 5°F—————
HSPF2CA-18S18C-HP8.0Non-ducted, up to 1.5 tons2%217495517
SEER2CA-18S18C-HP17.0Non-ducted, up to 1.5 tons8%217495517
EER2CA-24S18C-HP9.8Non-ducted, 2 tons13%217495516
Heating capacity at 5°F—————

All 5 CASI0 models in Explore

CASI0 size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
CASI0: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)None on this board (0 of 3 models have all five ratings)
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models have all five ratings)

All-around board, every manufacturer

Newest CASI0 certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified CASI0 outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
CA-30S18C-HPCASI0with ductless indoor unit CA-30S18E-HP2.5 tons28,000 Btu/h · Non-ducted——8.017.0None1217495520
CA-12S18C-HP1CASI0with ductless indoor unit CA-12S18E-HP11 ton12,000 Btu/h · Non-ducted——8.017.0None1217495519
CA-12S18C-HP2CASI0with ductless indoor unit CA-12S18E-HP21 ton12,000 Btu/h · Non-ducted——8.017.0None1217495518
CA-18S18C-HPCASI0with ductless indoor unit CA-18S18E-HP1.5 tons18,000 Btu/h · Non-ducted——8.017.0None1217495517
CA-24S18C-HPCASI0with ductless indoor unit CA-24S18E-HP2 tons24,000 Btu/h · Non-ducted——8.017.0None1217495516

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for CASI0 in this group.

Compare CASI0

Manufacturers of a similar size, side by side.

CASI0 includes these brand names as listed in AHRI: CASI0. Standards are checked against published thresholds; program rules beyond ratings are not checked.