COMFORMATIC heat pump efficiency: 6 outdoor models compared
COMFORMATIC has 6 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes COMFORMATIC makes. COMFORMATIC has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 6
- AHRI certifications
- 6
- Efficiency index
- 41%
- Typical model vs same-size, same-type peers (6 models)
- Meet CEE 2025
- 100%
- 6 models
How COMFORMATIC compares with comparable models
- COMFORMATIC
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index6 models scored | 41% | Not ranked | — |
| COP at 5°F6 models scored | 35% | Not ranked | 1.90 |
| Capacity retention at 5°F6 models scored | 39% | Not ranked | 72% |
| HSPF26 models scored | 21% | Not ranked | 8.5 |
| SEER26 models scored | 55% | Not ranked | 21.5 |
| EER26 models scored | 44% | Not ranked | 11.4 |
| Heating capacity at 5°F6 models scored | 40% | Not ranked | 11,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 6 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 83.3% | 5 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- COMFORMATIC (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 4 | 40% | 42% | 17% | 54% |
| Non-ducted, 2 tons | 1 | 54% | 36% | 44% | 63% |
| Non-ducted, 2.5–3 tons | 1 | 30% | 7% | 12% | 49% |
Every COMFORMATIC model in the market
- COMFORMATIC models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top COMFORMATIC models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AWGRC09-H2COMFORMATICwith ductless indoor unit AWGRE09-H2 | 1 ton9,100 Btu/h · Non-ducted | 79% | 1.90 | 9.2 | 7,700 | 22.0 | CEE 25CEE 26Xcel | 1 | 214796349 | Non-ducted, up to 1.5 tons | 45.6 |
| 2AWGRC12-H2COMFORMATICwith ductless indoor unit AWGRE12-H2 | 1 ton12,000 Btu/h · Non-ducted | 78% | 1.90 | 8.5 | 9,400 | 21.5 | CEE 25CEE 26Xcel | 1 | 214771916 | Non-ducted, up to 1.5 tons | 36.9 |
| 3AWGRC12-H1COMFORMATICwith ductless indoor unit AWGRE12-H1 | 1 ton12,000 Btu/h · Non-ducted | 71% | 1.90 | 8.5 | 8,500 | 21.5 | CEE 25CEE 26Xcel | 1 | 214771915 | Non-ducted, up to 1.5 tons | 27.2 |
| 4AWGRC18-H2COMFORMATICwith ductless indoor unit AWGRE18-H2 | 1.5 tons18,000 Btu/h · Non-ducted | 70% | 1.90 | 8.5 | 13,000 | 21.5 | CEE 25CEE 26Xcel | 1 | 214771917 | Non-ducted, up to 1.5 tons | 26.7 |
| 5AWGRC36-H2COMFORMATICwith ductless indoor unit AWGRE36-H2 | 3 tons33,600 Btu/h · Non-ducted | 72% | 1.80 | 8.5 | 24,600 | 21.0 | CEE 25CEE 26Xcel | 1 | 214771919 | Non-ducted, 2.5–3 tons | 22.3 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1AWGRXC24-H2COMFORMATICwith ductless indoor unit AWGRXE24-H2 | 2 tons22,000 Btu/h · Non-ducted | 64% | 1.95 | 9.5 | 22.0 | 13.7 | CEE 25CEE 26 | 1 | 214771918 | Non-ducted, 2 tons | 53.8 | 30.7 | 76.9 | Not a pick |
| 2AWGRC09-H2COMFORMATICwith ductless indoor unit AWGRE09-H2 | 1 ton9,100 Btu/h · Non-ducted | 79% | 1.90 | 9.2 | 22.0 | 12.3 | CEE 25CEE 26Xcel | 1 | 214796349 | Non-ducted, up to 1.5 tons | 50.3 | 45.6 | 55.0 | 45.6 |
| 3AWGRC12-H2COMFORMATICwith ductless indoor unit AWGRE12-H2 | 1 ton12,000 Btu/h · Non-ducted | 78% | 1.90 | 8.5 | 21.5 | 11.0 | CEE 25CEE 26Xcel | 1 | 214771916 | Non-ducted, up to 1.5 tons | 38.7 | 36.9 | 40.4 | 36.9 |
| 4AWGRC18-H2COMFORMATICwith ductless indoor unit AWGRE18-H2 | 1.5 tons18,000 Btu/h · Non-ducted | 70% | 1.90 | 8.5 | 21.5 | 11.8 | CEE 25CEE 26Xcel | 1 | 214771917 | Non-ducted, up to 1.5 tons | 35.8 | 26.7 | 44.9 | 26.7 |
| 5AWGRC12-H1COMFORMATICwith ductless indoor unit AWGRE12-H1 | 1 ton12,000 Btu/h · Non-ducted | 71% | 1.90 | 8.5 | 21.5 | 11.0 | CEE 25CEE 26Xcel | 1 | 214771915 | Non-ducted, up to 1.5 tons | 33.8 | 27.2 | 40.4 | 27.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | AWGRC12-H1 | 1.90 | Non-ducted, up to 1.5 tons | 42% | 214771915 |
| Capacity retention at 5°F | AWGRC09-H2 | 79% | Non-ducted, up to 1.5 tons | 58% | 214796349 |
| HSPF2 | AWGRXC24-H2 | 9.5 | Non-ducted, 2 tons | 43% | 214771918 |
| SEER2 | AWGRXC24-H2 | 22.0 | Non-ducted, 2 tons | 59% | 214771918 |
| EER2 | AWGRXC24-H2 | 13.7 | Non-ducted, 2 tons | 91% | 214771918 |
| Heating capacity at 5°F | AWGRC18-H2 | 13,000 Btu/h | Non-ducted, up to 1.5 tons | 74% | 214771917 |
COMFORMATIC size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 45.6(50 is the typical model of its size class)AWGRC09-H2with ductless indoor unit AWGRE09-H24 of 4 models qualify · AHRI 214796349 | 50.3(50 is the typical model of its size class)AWGRC09-H2with ductless indoor unit AWGRE09-H24 of 4 models have all five ratings · AHRI 214796349 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 53.8(50 is the typical model of its size class)AWGRXC24-H2with ductless indoor unit AWGRXE24-H21 of 1 models have all five ratings · AHRI 214771918 |
| Non-ducted, 2.5–3 tons | 22.3(50 is the typical model of its size class)AWGRC36-H2with ductless indoor unit AWGRE36-H21 of 1 models qualify · AHRI 214771919 | 30.4(50 is the typical model of its size class)AWGRC36-H2with ductless indoor unit AWGRE36-H21 of 1 models have all five ratings · AHRI 214771919 |
Newest COMFORMATIC certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| AWGRC09-H2COMFORMATICwith ductless indoor unit AWGRE09-H2 | 1 ton9,100 Btu/h · Non-ducted | 1.90 | 79% | 9.2 | 22.0 | CEE 25CEE 26Xcel | 1 | 214796349 |
| AWGRC36-H2COMFORMATICwith ductless indoor unit AWGRE36-H2 | 3 tons33,600 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 21.0 | CEE 25CEE 26Xcel | 1 | 214771919 |
| AWGRXC24-H2COMFORMATICwith ductless indoor unit AWGRXE24-H2 | 2 tons22,000 Btu/h · Non-ducted | 1.95 | 64% | 9.5 | 22.0 | CEE 25CEE 26 | 1 | 214771918 |
| AWGRC18-H2COMFORMATICwith ductless indoor unit AWGRE18-H2 | 1.5 tons18,000 Btu/h · Non-ducted | 1.90 | 70% | 8.5 | 21.5 | CEE 25CEE 26Xcel | 1 | 214771917 |
| AWGRC12-H2COMFORMATICwith ductless indoor unit AWGRE12-H2 | 1 ton12,000 Btu/h · Non-ducted | 1.90 | 78% | 8.5 | 21.5 | CEE 25CEE 26Xcel | 1 | 214771916 |
Compare COMFORMATIC
COMFORMATIC includes these brand names as listed in AHRI: COMFORMATIC. Standards are checked against published thresholds; program rules beyond ratings are not checked.