DREO heat pump efficiency: 4 outdoor models compared

DREO has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DREO makes. DREO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
34%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
50%
2 models

How DREO compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
DREO against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of DREO’s own modelsDREO is strongest on HSPF2 (its typical model beats 53% of comparable models) and weakest on COP at 5°F (20%).
  • DREO
  • Middle half of its models
  • Other ranked manufacturers
DREO

Source: AHRI Directory, NEEP · as of

Average peer percentile of DREO’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored34%Not ranked—
COP at 5°F4 models scored20%Not ranked1.80
Capacity retention at 5°F4 models scored42%Not ranked73%
HSPF24 models scored53%Not ranked9.5
SEER24 models scored33%Not ranked20.0
EER24 models scored28%Not ranked10.8
Heating capacity at 5°F4 models scored40%Not ranked8,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
DREO’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • DREO (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons434%20%53%33%

Every DREO model in the market

DREO’s 4 models with a known size and duct type, over the shape of the whole catalog.
DREO models by size and ratingColoured: DREO · grey shapes: all 15,936 models · lines: catalog medians by size
  • DREO models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 dreo models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top DREO models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 1 DREO cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1DR-HSCO001SODREOwith ductless indoor unit DR-HSC001SAAlso listed as DR-HSC001SO1 ton9,000 Btu/h · Non-ducted80%1.809.58,00020.0CEE 25CEE 26Xcel1218404691Non-ducted, up to 1.5 tons43.9

All-around best

Top 3 DREO models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1DR-HSCO001SODREOwith ductless indoor unit DR-HSC001SAAlso listed as DR-HSC001SO1 ton9,000 Btu/h · Non-ducted80%1.809.520.012.0CEE 25CEE 26Xcel1218404691Non-ducted, up to 1.5 tons42.043.940.143.9
2DR-HSC003SODREOwith ductless indoor unit DR-HSC003SA1.5 tons18,000 Btu/h · Non-ducted67%1.8010.020.09.5None1218472979Non-ducted, up to 1.5 tons28.235.521.0Not a pick
3DR-HSC002SODREOwith ductless indoor unit DR-HSC002SA1 ton12,000 Btu/h · Non-ducted67%1.809.520.09.5None1218472978Non-ducted, up to 1.5 tons25.029.021.0Not a pick

Best model on each rating

DREO’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDR-HSCO001SOAlso listed as DR-HSC001SO1.80Non-ducted, up to 1.5 tons20%218404691
Capacity retention at 5°FDR-HSCO001SOAlso listed as DR-HSC001SO80%Non-ducted, up to 1.5 tons63%218404691
HSPF2DR-HSC003SO10.0Non-ducted, up to 1.5 tons66%218472979
SEER2DR-HSCO001SOAlso listed as DR-HSC001SO20.0Non-ducted, up to 1.5 tons32%218404691
EER2DR-HSCO001SOAlso listed as DR-HSC001SO12.0Non-ducted, up to 1.5 tons47%218404691
Heating capacity at 5°FDR-HSC003SO12,000 Btu/hNon-ducted, up to 1.5 tons69%218472979

All 4 DREO models in Explore

DREO size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
DREO: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons43.9(50 is the typical model of its size class)DR-HSCO001SOwith ductless indoor unit DR-HSC001SAAlso listed as DR-HSC001SO2 of 4 models qualify · AHRI 21840469142.0(50 is the typical model of its size class)DR-HSCO001SOwith ductless indoor unit DR-HSC001SAAlso listed as DR-HSC001SO4 of 4 models have all five ratings · AHRI 218404691

All-around board, every manufacturer

Newest DREO certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified DREO outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
DR-HSC003SODREOwith ductless indoor unit DR-HSC003SA1.5 tons18,000 Btu/h · Non-ducted1.8067%10.020.0None1218472979
DR-HSC002SODREOwith ductless indoor unit DR-HSC002SA1 ton12,000 Btu/h · Non-ducted1.8067%9.520.0None1218472978
DR-HSC001SODREOwith ductless indoor unit DR-HSC001SA1 ton9,000 Btu/h · Non-ducted1.8080%9.520.0CEE 25CEE 26Xcel1218472977
DR-HSCO001SODREOwith ductless indoor unit DR-HSC001SA1 ton9,000 Btu/h · Non-ducted1.8080%9.520.0CEE 25CEE 26Xcel1218404691

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for DREO in this group.

Compare DREO

Manufacturers of a similar size, side by side.

DREO includes these brand names as listed in AHRI: DREO. Standards are checked against published thresholds; program rules beyond ratings are not checked.