Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
DWVO heat pump efficiency: 3 outdoor models compared
DWVO has 3 heat pump outdoor models certified with this refrigerant group, in 3 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes DWVO makes. DWVO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 3
- AHRI certifications
- 3
- Efficiency index
- 22%
- Typical model vs same-size, same-type peers (3 models)
- Meet CEE 2025
- 33.3%
- 1 model
How DWVO compares with comparable models
- DWVO
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index3 models scored | 22% | Not ranked | — |
| COP at 5°F3 models scored | 14% | Not ranked | 1.75 |
| Capacity retention at 5°F3 models scored | 31% | Not ranked | 70% |
| HSPF23 models scored | 10% | Not ranked | 7.5 |
| SEER23 models scored | 25% | Not ranked | 17.0 |
| EER23 models scored | 25% | Not ranked | 10.2 |
| Heating capacity at 5°F3 models scored | 22% | Not ranked | 7,400 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3% | 1 |
| CEE 2026 Tier 1 (Split ASHP) | 33.3% | 1 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 66.7% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- DWVO (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 3 | 22% | 14% | 10% | 25% |
Every DWVO model in the market
- DWVO models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top DWVO models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1IMHCAC-0039DWVOwith ductless indoor unit IMHCAC-0038 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.86 | 9.0 | 8,400 | 22.0 | CEE 25CEE 26Xcel | 1 | 217454971 | Non-ducted, up to 1.5 tons | 29.6 |
| 2IMHCAC-0043DWVOwith ductless indoor unit IMHCAC-0042 | 1 ton9,000 Btu/h · Non-ducted | 78% | 1.75 | 7.5 | 7,000 | 17.0 | Xcel | 1 | 217454969 | Non-ducted, up to 1.5 tons | 20.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1IMHCAC-0039DWVOwith ductless indoor unit IMHCAC-0038 | 1 ton12,000 Btu/h · Non-ducted | 70% | 1.86 | 9.0 | 22.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217454971 | Non-ducted, up to 1.5 tons | 40.3 | 29.6 | 51.0 | 29.6 |
| 2IMHCAC-0043DWVOwith ductless indoor unit IMHCAC-0042 | 1 ton9,000 Btu/h · Non-ducted | 78% | 1.75 | 7.5 | 17.0 | 10.2 | Xcel | 1 | 217454969 | Non-ducted, up to 1.5 tons | 16.9 | 20.8 | 13.0 | 20.8 |
| 3IMHCAC-0041DWVOwith ductless indoor unit IMHCAC-0040 | 1 ton12,000 Btu/h · Non-ducted | 62% | 1.70 | 7.5 | 17.0 | 9.8 | None | 1 | 217454970 | Non-ducted, up to 1.5 tons | 7.4 | 4.2 | 10.6 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | IMHCAC-0039 | 1.86 | Non-ducted, up to 1.5 tons | 36% | 217454971 |
| Capacity retention at 5°F | IMHCAC-0043 | 78% | Non-ducted, up to 1.5 tons | 57% | 217454969 |
| HSPF2 | IMHCAC-0039 | 9.0 | Non-ducted, up to 1.5 tons | 29% | 217454971 |
| SEER2 | IMHCAC-0039 | 22.0 | Non-ducted, up to 1.5 tons | 56% | 217454971 |
| EER2 | IMHCAC-0039 | 12.0 | Non-ducted, up to 1.5 tons | 44% | 217454971 |
| Heating capacity at 5°F | IMHCAC-0039 | 8,400 Btu/h | Non-ducted, up to 1.5 tons | 34% | 217454971 |
DWVO size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 29.6(50 is the typical model of its size class)IMHCAC-0039with ductless indoor unit IMHCAC-00382 of 3 models qualify · AHRI 217454971 | 40.3(50 is the typical model of its size class)IMHCAC-0039with ductless indoor unit IMHCAC-00383 of 3 models have all five ratings · AHRI 217454971 |
Newest DWVO certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| IMHCAC-0039DWVOwith ductless indoor unit IMHCAC-0038 | 1 ton12,000 Btu/h · Non-ducted | 1.86 | 70% | 9.0 | 22.0 | CEE 25CEE 26Xcel | 1 | 217454971 |
| IMHCAC-0041DWVOwith ductless indoor unit IMHCAC-0040 | 1 ton12,000 Btu/h · Non-ducted | 1.70 | 62% | 7.5 | 17.0 | None | 1 | 217454970 |
| IMHCAC-0043DWVOwith ductless indoor unit IMHCAC-0042 | 1 ton9,000 Btu/h · Non-ducted | 1.75 | 78% | 7.5 | 17.0 | Xcel | 1 | 217454969 |
Compare DWVO
DWVO includes these brand names as listed in AHRI: DWVO. Standards are checked against published thresholds; program rules beyond ratings are not checked.