Electrolux heat pump efficiency: 8 outdoor models compared
Electrolux has 8 heat pump outdoor models certified with this refrigerant group, in 8 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Electrolux makes. Electrolux has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 8
- AHRI certifications
- 8
- Efficiency index
- 51%
- Typical model vs same-size, same-type peers (6 models)
- Meet CEE 2025
- 62.5%
- 5 models
How Electrolux compares with comparable models
- Electrolux
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index6 models scored | 51% | Not ranked | — |
| COP at 5°F8 models scored | 45% | Not ranked | 1.90 |
| Capacity retention at 5°F6 models scored | 58% | Not ranked | 83% |
| HSPF28 models scored | 43% | Not ranked | 9.5 |
| SEER28 models scored | 55% | Not ranked | 21.8 |
| EER28 models scored | 42% | Not ranked | 11.5 |
| Heating capacity at 5°F7 models scored | 39% | Not ranked | 10,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 62.5% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 62.5% | 5 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 62.5% | 5 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Electrolux (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 6 | 54% | 40% | 43% | 55% |
| Non-ducted, 2 tons | 2 | 46% | 60% | 43% | 55% |
Every Electrolux model in the market
- Electrolux models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Electrolux models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1SAC24SHV22-1-OElectroluxwith ductless indoor unit SAC24SHV22-1-I | 2 tons23,000 Btu/h · Non-ducted | 73% | 2.10 | 10.0 | 17,500 | 23.0 | CEE 25CEE 26Xcel | 1 | 218160022 | Non-ducted, 2 tons | 63.4 |
| 2SAC09SNV23-1-OElectroluxwith ductless indoor unit SAC09SNV23-1-I | 1 ton9,000 Btu/h · Non-ducted | 89% | 1.80 | 10.0 | 8,000 | 23.0 | CEE 25CEE 26Xcel | 1 | 218160019 | Non-ducted, up to 1.5 tons | 53.6 |
| 3SAC12SNV23-1-OElectroluxwith ductless indoor unit SAC12SNV23-1-I | 1 ton12,000 Btu/h · Non-ducted | 83% | 1.80 | 10.0 | 10,000 | 24.0 | CEE 25CEE 26Xcel | 1 | 218160020 | Non-ducted, up to 1.5 tons | 52.7 |
| 4SAC18SHV22-1-OElectroluxwith ductless indoor unit SAC18SHV22-1-I | 1.5 tons18,000 Btu/h · Non-ducted | 83% | 1.80 | 10.0 | 15,000 | 24.0 | CEE 25CEE 26Xcel | 1 | 218160021 | Non-ducted, up to 1.5 tons | 52.7 |
| 5SAC09SNV19-1-OElectroluxwith ductless indoor unit SAC09SNV19-1-I | 1 ton9,100 Btu/h · Non-ducted | 88% | 1.80 | 8.5 | 8,800 | 20.5 | CEE 25CEE 26Xcel | 1 | 218126348 | Non-ducted, up to 1.5 tons | 34.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1SAC24SHV22-1-OElectroluxwith ductless indoor unit SAC24SHV22-1-I | 2 tons23,000 Btu/h · Non-ducted | 73% | 2.10 | 10.0 | 23.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 218160022 | Non-ducted, 2 tons | 67.0 | 63.4 | 70.6 | 63.4 |
| 2SAC12SNV23-1-OElectroluxwith ductless indoor unit SAC12SNV23-1-I | 1 ton12,000 Btu/h · Non-ducted | 83% | 1.80 | 10.0 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 218160020 | Non-ducted, up to 1.5 tons | 65.3 | 52.7 | 77.8 | 52.7 |
| 3SAC18SHV22-1-OElectroluxwith ductless indoor unit SAC18SHV22-1-I | 1.5 tons18,000 Btu/h · Non-ducted | 83% | 1.80 | 10.0 | 24.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 218160021 | Non-ducted, up to 1.5 tons | 58.4 | 52.7 | 64.1 | 52.7 |
| 4SAC09SNV23-1-OElectroluxwith ductless indoor unit SAC09SNV23-1-I | 1 ton9,000 Btu/h · Non-ducted | 89% | 1.80 | 10.0 | 23.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 218160019 | Non-ducted, up to 1.5 tons | 56.6 | 53.6 | 59.6 | 53.6 |
| 5SAC09SNV19-1-OElectroluxwith ductless indoor unit SAC09SNV19-1-I | 1 ton9,100 Btu/h · Non-ducted | 88% | 1.80 | 8.5 | 20.5 | 10.9 | CEE 25CEE 26Xcel | 1 | 218126348 | Non-ducted, up to 1.5 tons | 35.4 | 34.9 | 35.8 | 34.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | SAC18SHV19-1-O | 2.20 | Non-ducted, up to 1.5 tons | 86% | 218126350 |
| Capacity retention at 5°F | SAC09SNV23-1-O | 89% | Non-ducted, up to 1.5 tons | 73% | 218160019 |
| HSPF2 | SAC24SHV22-1-O | 10.0 | Non-ducted, 2 tons | 71% | 218160022 |
| SEER2 | SAC24SHV22-1-O | 23.0 | Non-ducted, 2 tons | 81% | 218160022 |
| EER2 | SAC12SNV23-1-O | 13.0 | Non-ducted, up to 1.5 tons | 73% | 218160020 |
| Heating capacity at 5°F | SAC18SHV22-1-O | 15,000 Btu/h | Non-ducted, up to 1.5 tons | 87% | 218160021 |
Electrolux size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 53.6(50 is the typical model of its size class)SAC09SNV23-1-Owith ductless indoor unit SAC09SNV23-1-I4 of 6 models qualify · AHRI 218160019 | 65.3(50 is the typical model of its size class)SAC12SNV23-1-Owith ductless indoor unit SAC12SNV23-1-I4 of 6 models have all five ratings · AHRI 218160020 |
| Non-ducted, 2 tons | 63.4(50 is the typical model of its size class)SAC24SHV22-1-Owith ductless indoor unit SAC24SHV22-1-I1 of 2 models qualify · AHRI 218160022 | 67.0(50 is the typical model of its size class)SAC24SHV22-1-Owith ductless indoor unit SAC24SHV22-1-I2 of 2 models have all five ratings · AHRI 218160022 |
Newest Electrolux certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| SAC24SHV22-1-OElectroluxwith ductless indoor unit SAC24SHV22-1-I | 2 tons23,000 Btu/h · Non-ducted | 2.10 | 73% | 10.0 | 23.0 | CEE 25CEE 26Xcel | 1 | 218160022 |
| SAC18SHV22-1-OElectroluxwith ductless indoor unit SAC18SHV22-1-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 83% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 218160021 |
| SAC12SNV23-1-OElectroluxwith ductless indoor unit SAC12SNV23-1-I | 1 ton12,000 Btu/h · Non-ducted | 1.80 | 83% | 10.0 | 24.0 | CEE 25CEE 26Xcel | 1 | 218160020 |
| SAC09SNV23-1-OElectroluxwith ductless indoor unit SAC09SNV23-1-I | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 89% | 10.0 | 23.0 | CEE 25CEE 26Xcel | 1 | 218160019 |
| SAC24SHV19-1-OElectroluxwith ductless indoor unit SAC24SHV19-1-I | 2 tons23,000 Btu/h · Non-ducted | 2.00 | 58% | 8.5 | 19.0 | None | 1 | 218126351 |
Compare Electrolux