- Insights
- Manufacturers
- Endura
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Endura heat pump efficiency: 9 outdoor models compared
Endura has 9 heat pump outdoor models certified with this refrigerant group, in 25 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Endura makes. Endura has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 9
- AHRI certifications
- 25
- Efficiency index
- 63%
- Typical model vs same-size, same-type peers (13 models)
- Meet CEE 2025
- 100%
- 9 models
How Endura compares with comparable models
- Endura
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index13 models scored | 63% | Not ranked | — |
| COP at 5°F13 models scored | 47% | Not ranked | 1.99 |
| Capacity retention at 5°F13 models scored | 73% | Not ranked | 77% |
| HSPF213 models scored | 57% | Not ranked | 9.0 |
| SEER213 models scored | 69% | Not ranked | 19.0 |
| EER213 models scored | 66% | Not ranked | 12.0 |
| Heating capacity at 5°F13 models scored | 69% | Not ranked | 36,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 9 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 9 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 9 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 9 |
Sizes and duct types offered
- Endura (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 65% | 57% | 59% | 57% |
| Ducted, 2 tons | 1 | 44% | 92% | 30% | 37% |
| Ducted, 2.5–3 tons | 4 | 63% | 40% | 59% | 70% |
| Ducted, 3.5–4.5 tons | 2 | 71% | 58% | 70% | 82% |
| Ducted, 5 tons and up | 1 | 81% | 98% | 74% | 97% |
| Non-ducted, up to 1.5 tons | 1 | 69% | 56% | 66% | 58% |
| Non-ducted, 2.5–3 tons | 2 | 63% | 12% | 59% | 67% |
| Non-ducted, 3.5–4.5 tons | 1 | 44% | 7% | 14% | 73% |
Every Endura model in the market
- Endura models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Endura models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HBEFU-60R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC60R454B | 5 tons57,000 Btu/h · Ducted | 75% | 2.42 | 9.0 | 42,500 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 218457848 | Ducted, 5 tons and up | 88.7 |
| 2HBEFU-36R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC36R454B | 2.5 tons32,000 Btu/h · Ducted | 97% | 2.15 | 10.5 | 31,000 | 19.5 | CEE 25CEE 26XcelES CC | 3 | 218457846 | Ducted, 2.5–3 tons | 87.9 |
| 3HBEFU-24R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC24R454B | 2 tons24,000 Btu/h · Ducted | 88% | 2.30 | 10.0 | 21,000 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 218457845 | Ducted, 2 tons | 82.1 |
| 4HBEFU-48R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC48R454B | 4 tons48,000 Btu/h · Ducted | 77% | 2.52 | 9.0 | 37,000 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 218457847 | Ducted, 3.5–4.5 tons | 77.3 |
| 5HBEFLM2-OD18Endura · HB Endura Flex Multi | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 18,000 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218457861 | Non-ducted, up to 1.5 tons | 69.5 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HBEFU-36R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC36R454B | 2.5 tons32,000 Btu/h · Ducted | 97% | 2.15 | 10.5 | 19.5 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 218457846 | Ducted, 2.5–3 tons | 82.3 | 87.9 | 76.7 | 87.9 |
| 2HBEFU-48R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC48R454B | 4 tons48,000 Btu/h · Ducted | 77% | 2.52 | 9.0 | 19.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218457847 | Ducted, 3.5–4.5 tons | 82.3 | 77.3 | 87.4 | 77.3 |
| 3HBEFU-60R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC60R454B | 5 tons57,000 Btu/h · Ducted | 75% | 2.42 | 9.0 | 19.0 | 11.0 | CEE 25CEE 26XcelES CC | 3 | 218457848 | Ducted, 5 tons and up | 81.1 | 88.7 | 73.4 | 88.7 |
| 4HBEFU-24R454BEndura · HB Endura Fusion Serieswith ducted air handler HBEC-FC24R454B | 2 tons24,000 Btu/h · Ducted | 88% | 2.30 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 218457845 | Ducted, 2 tons | 79.5 | 82.1 | 77.0 | 82.1 |
| 5HBEFLM4-OD36Endura · HB Endura Flex Multi | 3 tons36,000 Btu/h · Ducted | 90% | 1.80 | 9.0 | 19.0 | 12.9 | CEE 25CEE 26XcelES CC | 3 | 218457870 | Ducted, 2.5–3 tons | 72.3 | 54.3 | 90.4 | 54.3 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | HBEFU-60R454B | 2.42 | Ducted, 5 tons and up | 98% | 218457848 |
| Capacity retention at 5°F | HBEFU-60R454B | 75% | Ducted, 5 tons and up | 94% | 218457848 |
| HSPF2 | HBEFU-36R454B | 10.5 | Ducted, 2.5–3 tons | 96% | 218457846 |
| SEER2 | HBEFU-60R454B | 19.0 | Ducted, 5 tons and up | 95% | 218457848 |
| EER2 | HBEFLM4-OD36 | 12.9 | Ducted, 2.5–3 tons | 94% | 218457870 |
| Heating capacity at 5°F | HBEFLM2-OD18 | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 93% | 218457861 |
Endura size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 66.2(50 is the typical model of its size class)HBEFLM2-OD181 of 1 models qualify · AHRI 218457862 | 64.6(50 is the typical model of its size class)HBEFLM2-OD181 of 1 models have all five ratings · AHRI 218457862 |
| Ducted, 2 tons | 82.1(50 is the typical model of its size class)HBEFU-24R454Bwith ducted air handler HBEC-FC24R454B1 of 1 models qualify · AHRI 218457845 | 79.5(50 is the typical model of its size class)HBEFU-24R454Bwith ducted air handler HBEC-FC24R454B1 of 1 models have all five ratings · AHRI 218457845 |
| Ducted, 2.5–3 tons | 87.9(50 is the typical model of its size class)HBEFU-36R454Bwith ducted air handler HBEC-FC36R454B4 of 4 models qualify · AHRI 218457846 | 82.3(50 is the typical model of its size class)HBEFU-36R454Bwith ducted air handler HBEC-FC36R454B4 of 4 models have all five ratings · AHRI 218457846 |
| Ducted, 3.5–4.5 tons | 77.3(50 is the typical model of its size class)HBEFU-48R454Bwith ducted air handler HBEC-FC48R454B2 of 2 models qualify · AHRI 218457847 | 82.3(50 is the typical model of its size class)HBEFU-48R454Bwith ducted air handler HBEC-FC48R454B2 of 2 models have all five ratings · AHRI 218457847 |
| Ducted, 5 tons and up | 88.7(50 is the typical model of its size class)HBEFU-60R454Bwith ducted air handler HBEC-FC60R454B1 of 1 models qualify · AHRI 218457848 | 81.1(50 is the typical model of its size class)HBEFU-60R454Bwith ducted air handler HBEC-FC60R454B1 of 1 models have all five ratings · AHRI 218457848 |
| Non-ducted, up to 1.5 tons | 69.5(50 is the typical model of its size class)HBEFLM2-OD181 of 1 models qualify · AHRI 218457861 | 69.2(50 is the typical model of its size class)HBEFLM2-OD181 of 1 models have all five ratings · AHRI 218457861 |
| Non-ducted, 2.5–3 tons | 53.7(50 is the typical model of its size class)HBEFLM4-OD362 of 2 models qualify · AHRI 218457871 | 64.2(50 is the typical model of its size class)HBEFLM3-OD272 of 2 models have all five ratings · AHRI 218457864 |
| Non-ducted, 3.5–4.5 tons | 16.4(50 is the typical model of its size class)HBEFLM5-OD421 of 1 models qualify · AHRI 218457868 | 43.7(50 is the typical model of its size class)HBEFLM5-OD421 of 1 models have all five ratings · AHRI 218457868 |
Newest Endura certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| HBEFU-60R454BEndurawith ducted air handler D(A,C,E)61C4J+TDR | 4 tons49,500 Btu/h · Ducted | 2.30 | 61% | 7.8 | 16.0 | CEE 25CEE 26XcelES CC | 3 | 218827278 |
| HBEFU-48R454BEndurawith ducted air handler D(A,C,E)49B3J+TDR | 4 tons45,000 Btu/h · Ducted | 2.38 | 72% | 7.8 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 218827277 |
| HBEFU-36R454BEndurawith ducted air handler D(A,C,E)37D3J+TDR | 2.5 tons32,000 Btu/h · Ducted | 2.30 | 77% | 8.1 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 218827276 |
| HBEFU-24R454BEndurawith ducted air handler D(A,C,E)31D2J+TDR | 2 tons22,400 Btu/h · Ducted | 2.53 | 74% | 7.8 | 16.0 | CEE 25CEE 26XcelES CC | 3 | 218827275 |
| HBEFLM4-OD36Endura · HB Endura Flex Multi | 3 tons36,000 Btu/h · Ducted and non-ducted and mixed (multi-zone) | 1.87 | 95% | 9.5 | 20.5 | CEE 25CEE 26XcelES CC | 3 | 218457872 |
Compare Endura
Endura includes these brand names as listed in AHRI: Endura. Standards are checked against published thresholds; program rules beyond ratings are not checked.