Skip to content

EnerGlow heat pump efficiency: 4 outdoor models compared

EnerGlow has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes EnerGlow makes. EnerGlow has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
42%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How EnerGlow compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
EnerGlow against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of EnerGlow’s own modelsEnerGlow is strongest on COP at 5°F (its typical model beats 52% of comparable models) and weakest on EER2 (31%).
  • EnerGlow
  • Middle half of its models
  • Other ranked manufacturers
EnerGlow

Source: AHRI Directory, NEEP · as of

Average peer percentile of EnerGlow’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored42%Not ranked—
COP at 5°F4 models scored52%Not ranked2.00
Capacity retention at 5°F4 models scored46%Not ranked74%
HSPF24 models scored38%Not ranked9.5
SEER24 models scored45%Not ranked20.0
EER24 models scored31%Not ranked11.0
Heating capacity at 5°F4 models scored47%Not ranked26,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
EnerGlow’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • EnerGlow (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons162%63%66%88%
Non-ducted, 2.5–3 tons239%53%36%31%
Non-ducted, 3.5–4.5 tons127%37%14%30%

Every EnerGlow model in the market

EnerGlow’s 4 models with a known size and duct type, over the shape of the whole catalog.
EnerGlow models by size and ratingColoured: EnerGlow · grey shapes: all 14,508 models · lines: catalog medians by size
  • EnerGlow models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 energlow models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top EnerGlow models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 EnerGlow cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1SAC003-B-20KWH-USTPEnerGlow1.5 tons18,000 Btu/h · Non-ducted78%2.0010.014,00025.0CEE 25CEE 26Xcel1218352787Non-ducted, up to 1.5 tons62.1
2SAC003-B-28KWH-USTPEnerGlow2.5 tons28,000 Btu/h · Non-ducted75%2.009.521,00020.0CEE 25CEE 26Xcel1218352788Non-ducted, 2.5–3 tons47.6
3SAC003-B-36KWH-USTPEnerGlow3 tons38,000 Btu/h · Non-ducted74%2.009.531,00020.0CEE 25CEE 26Xcel1218352789Non-ducted, 2.5–3 tons46.9
4SAC003-B-42KWH-USTPEnerGlow3.5 tons42,000 Btu/h · Non-ducted74%2.009.531,00020.0CEE 25CEE 26Xcel1218352790Non-ducted, 3.5–4.5 tons24.7

All-around best

Top 4 EnerGlow models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1SAC003-B-20KWH-USTPEnerGlow1.5 tons18,000 Btu/h · Non-ducted78%2.0010.025.011.7CEE 25CEE 26Xcel1218352787Non-ducted, up to 1.5 tons62.262.162.462.1
2SAC003-B-28KWH-USTPEnerGlow2.5 tons28,000 Btu/h · Non-ducted75%2.009.520.011.0CEE 25CEE 26Xcel1218352788Non-ducted, 2.5–3 tons38.747.629.747.6
3SAC003-B-36KWH-USTPEnerGlow3 tons38,000 Btu/h · Non-ducted74%2.009.520.011.0CEE 25CEE 26Xcel1218352789Non-ducted, 2.5–3 tons38.346.929.746.9
4SAC003-B-42KWH-USTPEnerGlow3.5 tons42,000 Btu/h · Non-ducted74%2.009.520.011.0CEE 25CEE 26Xcel1218352790Non-ducted, 3.5–4.5 tons27.224.729.724.7

Best model on each rating

EnerGlow’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FSAC003-B-20KWH-USTP2.00Non-ducted, up to 1.5 tons63%218352787
Capacity retention at 5°FSAC003-B-20KWH-USTP78%Non-ducted, up to 1.5 tons57%218352787
HSPF2SAC003-B-20KWH-USTP10.0Non-ducted, up to 1.5 tons64%218352787
SEER2SAC003-B-20KWH-USTP25.0Non-ducted, up to 1.5 tons84%218352787
EER2SAC003-B-20KWH-USTP11.7Non-ducted, up to 1.5 tons36%218352787
Heating capacity at 5°FSAC003-B-20KWH-USTP14,000 Btu/hNon-ducted, up to 1.5 tons83%218352787

All 4 EnerGlow models in Explore

EnerGlow size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
EnerGlow: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons62.1(50 is the typical model of its size class)SAC003-B-20KWH-USTP1 of 1 models qualify · AHRI 21835278762.2(50 is the typical model of its size class)SAC003-B-20KWH-USTP1 of 1 models have all five ratings · AHRI 218352787
Non-ducted, 2.5–3 tons47.6(50 is the typical model of its size class)SAC003-B-28KWH-USTP2 of 2 models qualify · AHRI 21835278838.7(50 is the typical model of its size class)SAC003-B-28KWH-USTP2 of 2 models have all five ratings · AHRI 218352788
Non-ducted, 3.5–4.5 tons24.7(50 is the typical model of its size class)SAC003-B-42KWH-USTP1 of 1 models qualify · AHRI 21835279027.2(50 is the typical model of its size class)SAC003-B-42KWH-USTP1 of 1 models have all five ratings · AHRI 218352790

All-around board, every manufacturer

Newest EnerGlow certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified EnerGlow outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
SAC003-B-42KWH-USTPEnerGlow3.5 tons42,000 Btu/h · Non-ducted2.0074%9.520.0CEE 25CEE 26Xcel1218352790
SAC003-B-36KWH-USTPEnerGlow3 tons38,000 Btu/h · Non-ducted2.0074%9.520.0CEE 25CEE 26Xcel1218352789
SAC003-B-28KWH-USTPEnerGlow2.5 tons28,000 Btu/h · Non-ducted2.0075%9.520.0CEE 25CEE 26Xcel1218352788
SAC003-B-20KWH-USTPEnerGlow1.5 tons18,000 Btu/h · Non-ducted2.0078%10.025.0CEE 25CEE 26Xcel1218352787

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for EnerGlow in this group.

Compare EnerGlow

Manufacturers of a similar size, side by side.

EnerGlow includes these brand names as listed in AHRI: EnerGlow. Standards are checked against published thresholds; program rules beyond ratings are not checked.