Skip to content

HEMA heat pump efficiency: 5 outdoor models compared

HEMA has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes HEMA makes. HEMA has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
5
Efficiency index
33%
Typical model vs same-size, same-type peers (5 models)
Meet CEE 2025
40%
2 models

How HEMA compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
HEMA against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of HEMA’s own modelsHEMA is strongest on HSPF2 (its typical model beats 43% of comparable models) and weakest on capacity retention at 5°F (19%).
  • HEMA
  • Middle half of its models
  • Other ranked manufacturers
HEMA

Source: AHRI Directory, NEEP · as of

Average peer percentile of HEMA’s models
RatingBeats comparable modelsRankRaw median
Efficiency index5 models scored33%Not ranked—
COP at 5°F5 models scored39%Not ranked1.90
Capacity retention at 5°F5 models scored19%Not ranked70%
HSPF25 models scored43%Not ranked9.5
SEER25 models scored32%Not ranked17.0
EER25 models scored34%Not ranked9.5
Heating capacity at 5°F5 models scored29%Not ranked8,900 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
HEMA’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • HEMA (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons438%45%42%39%
Non-ducted, 2 tons113%17%44%4%

Every HEMA model in the market

HEMA’s 5 models with a known size and duct type, over the shape of the whole catalog.
HEMA models by size and ratingColoured: HEMA · grey shapes: all 14,508 models · lines: catalog medians by size
  • HEMA models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 hema models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top HEMA models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 2 HEMA cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1DS-2MS1212HC231HEMA · T-Prowith ductless indoor unit DS-2MS1212HE2311 ton12,000 Btu/h · Non-ducted72%2.1010.08,90023.0CEE 25CEE 26XcelES CC1217463854Non-ducted, up to 1.5 tons58.9
2DS-2MS0912HC240HEMA · T-Prowith ductless indoor unit DS-2MS0912HE2401 ton9,000 Btu/h · Non-ducted71%1.909.57,10023.0CEE 25CEE 26XcelES CC1217463853Non-ducted, up to 1.5 tons39.5

All-around best

Top 5 HEMA models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1DS-2MS1212HC231HEMA · T-Prowith ductless indoor unit DS-2MS1212HE2311 ton12,000 Btu/h · Non-ducted72%2.1010.023.013.0CEE 25CEE 26XcelES CC1217463854Non-ducted, up to 1.5 tons65.058.971.158.9
2DS-2MS0912HC240HEMA · T-Prowith ductless indoor unit DS-2MS0912HE2401 ton9,000 Btu/h · Non-ducted71%1.909.523.013.0CEE 25CEE 26XcelES CC1217463853Non-ducted, up to 1.5 tons55.339.571.139.5
3DS-2MS1211HC170HEMAwith ductless indoor unit DS-2MS1211HE1701 ton11,500 Btu/h · Non-ducted70%1.909.517.09.5None1217463850Non-ducted, up to 1.5 tons22.136.37.9Not a pick
4DS-2MS2421HC170HEMAwith ductless indoor unit DS-2MS2421HE1702 tons23,000 Btu/h · Non-ducted54%1.809.517.09.5None1217463852Non-ducted, 2 tons13.421.45.3Not a pick
5DS-2MS1821HC170HEMAwith ductless indoor unit DS-2MS1821HE1701.5 tons17,000 Btu/h · Non-ducted58%1.808.517.09.5None1217463851Non-ducted, up to 1.5 tons9.511.07.9Not a pick

Best model on each rating

HEMA’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FDS-2MS1212HC2312.10Non-ducted, up to 1.5 tons77%217463854
Capacity retention at 5°FDS-2MS1212HC23172%Non-ducted, up to 1.5 tons34%217463854
HSPF2DS-2MS1212HC23110.0Non-ducted, up to 1.5 tons64%217463854
SEER2DS-2MS0912HC24023.0Non-ducted, up to 1.5 tons64%217463853
EER2DS-2MS0912HC24013.0Non-ducted, up to 1.5 tons70%217463853
Heating capacity at 5°FDS-2MS1821HC1709,500 Btu/hNon-ducted, up to 1.5 tons52%217463851

All 5 HEMA models in Explore

HEMA size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
HEMA: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons58.9(50 is the typical model of its size class)DS-2MS1212HC231with ductless indoor unit DS-2MS1212HE2312 of 4 models qualify · AHRI 21746385465.0(50 is the typical model of its size class)DS-2MS1212HC231with ductless indoor unit DS-2MS1212HE2314 of 4 models have all five ratings · AHRI 217463854
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)13.4(50 is the typical model of its size class)DS-2MS2421HC170with ductless indoor unit DS-2MS2421HE1701 of 1 models have all five ratings · AHRI 217463852

All-around board, every manufacturer

Newest HEMA certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified HEMA outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
DS-2MS1212HC231HEMA · T-Prowith ductless indoor unit DS-2MS1212HE2311 ton12,000 Btu/h · Non-ducted2.1072%10.023.0CEE 25CEE 26XcelES CC1217463854
DS-2MS0912HC240HEMA · T-Prowith ductless indoor unit DS-2MS0912HE2401 ton9,000 Btu/h · Non-ducted1.9071%9.523.0CEE 25CEE 26XcelES CC1217463853
DS-2MS2421HC170HEMAwith ductless indoor unit DS-2MS2421HE1702 tons23,000 Btu/h · Non-ducted1.8054%9.517.0None1217463852
DS-2MS1821HC170HEMAwith ductless indoor unit DS-2MS1821HE1701.5 tons17,000 Btu/h · Non-ducted1.8058%8.517.0None1217463851
DS-2MS1211HC170HEMAwith ductless indoor unit DS-2MS1211HE1701 ton11,500 Btu/h · Non-ducted1.9070%9.517.0None1217463850

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for HEMA in this group.

Compare HEMA

Manufacturers of a similar size, side by side.

HEMA includes these brand names as listed in AHRI: HEMA. Standards are checked against published thresholds; program rules beyond ratings are not checked.