Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
INOMA heat pump efficiency: 8 outdoor models compared
INOMA has 8 heat pump outdoor models certified with this refrigerant group, in 8 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes INOMA makes. INOMA has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 8
- AHRI certifications
- 8
- Efficiency index
- 72%
- Typical model vs same-size, same-type peers (8 models)
- Meet CEE 2025
- 100%
- 8 models
How INOMA compares with comparable models
- INOMA
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index8 models scored | 72% | Not ranked | — |
| COP at 5°F8 models scored | 36% | Not ranked | 1.90 |
| Capacity retention at 5°F8 models scored | 76% | Not ranked | 96% |
| HSPF28 models scored | 70% | Not ranked | 10.0 |
| SEER28 models scored | 88% | Not ranked | 25.0 |
| EER28 models scored | 78% | Not ranked | 13.6 |
| Heating capacity at 5°F8 models scored | 72% | Not ranked | 24,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 8 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 8 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 8 |
Sizes and duct types offered
- INOMA (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 3 | 66% | 19% | 71% | 80% |
| Non-ducted, 2 tons | 1 | 56% | 17% | 70% | 70% |
| Non-ducted, 2.5–3 tons | 4 | 80% | 53% | 70% | 98% |
Every INOMA model in the market
- INOMA models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top INOMA models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1INM-27K-OINOMA · EcostarAlso listed as INM-27K-O | 2.5 tons27,000 Btu/h · Non-ducted | 96% | 2.00 | 10.5 | 26,000 | 26.5 | CEE 25CEE 26XcelES CC | 1 | 218620876 | Non-ducted, 2.5–3 tons | 68.0 |
| 2INS-12K-OINOMA · Ecostarwith ductless indoor unit INS-12K-I | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 12,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218620873 | Non-ducted, up to 1.5 tons | 62.1 |
| 3INS-24K-OINOMA · Ecostarwith ductless indoor unit INS-24K-I | 2 tons24,000 Btu/h · Non-ducted | 93% | 1.80 | 10.0 | 22,400 | 22.5 | CEE 25CEE 26XcelES CC | 1 | 218620875 | Non-ducted, 2 tons | 58.0 |
| 4INM-36K-OINOMA · EcostarAlso listed as INM-36K-O | 3 tons36,000 Btu/h · Non-ducted | 83% | 2.00 | 10.0 | 30,000 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218620877 | Non-ducted, 2.5–3 tons | 57.7 |
| 5INS-18K-OINOMA · Ecostarwith ductless indoor unit INS-18K-IAlso listed as INS-18K-O | 1.5 tons18,000 Btu/h · Non-ducted | 99% | 1.80 | 10.0 | 17,800 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218620874 | Non-ducted, up to 1.5 tons | 55.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1INM-27K-OINOMA · EcostarAlso listed as INM-27K-O | 2.5 tons27,000 Btu/h · Non-ducted | 96% | 2.00 | 10.5 | 26.5 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218620876 | Non-ducted, 2.5–3 tons | 83.1 | 68.0 | 98.1 | 68.0 |
| 2INM-36K-OINOMA · EcostarAlso listed as INM-36K-O | 3 tons36,000 Btu/h · Non-ducted | 83% | 2.00 | 10.0 | 25.0 | 13.6 | CEE 25CEE 26XcelES CC | 1 | 218620877 | Non-ducted, 2.5–3 tons | 76.4 | 57.7 | 95.1 | 57.7 |
| 3INS-12K-OINOMA · Ecostarwith ductless indoor unit INS-12K-I | 1 ton12,000 Btu/h · Non-ducted | 100% | 1.80 | 10.5 | 25.0 | 14.0 | CEE 25CEE 26XcelES CC | 1 | 218620873 | Non-ducted, up to 1.5 tons | 74.4 | 62.1 | 86.7 | 62.1 |
| 4INS-18K-OINOMA · Ecostarwith ductless indoor unit INS-18K-IAlso listed as INS-18K-O | 1.5 tons18,000 Btu/h · Non-ducted | 99% | 1.80 | 10.0 | 23.5 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 218620874 | Non-ducted, up to 1.5 tons | 61.2 | 55.8 | 66.5 | 55.8 |
| 5INS-24K-OINOMA · Ecostarwith ductless indoor unit INS-24K-I | 2 tons24,000 Btu/h · Non-ducted | 93% | 1.80 | 10.0 | 22.5 | 11.7 | CEE 25CEE 26XcelES CC | 1 | 218620875 | Non-ducted, 2 tons | 56.1 | 58.0 | 54.2 | 58.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | INM-27K-OAlso listed as INM-27K-O | 2.00 | Non-ducted, 2.5–3 tons | 53% | 218620876 |
| Capacity retention at 5°F | INS-12K-O | 100% | Non-ducted, up to 1.5 tons | 87% | 218620873 |
| HSPF2 | INM-27K-OAlso listed as INM-27K-O | 10.5 | Non-ducted, 2.5–3 tons | 80% | 218620876 |
| SEER2 | INM-27K-OAlso listed as INM-27K-O | 26.5 | Non-ducted, 2.5–3 tons | 99% | 218620876 |
| EER2 | INM-27K-OAlso listed as INM-27K-O | 14.0 | Non-ducted, 2.5–3 tons | 97% | 218620876 |
| Heating capacity at 5°F | INS-18K-OAlso listed as INS-18K-O | 17,800 Btu/h | Non-ducted, up to 1.5 tons | 90% | 218620874 |
INOMA size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 62.1(50 is the typical model of its size class)INS-12K-Owith ductless indoor unit INS-12K-I3 of 3 models qualify · AHRI 218620873 | 74.4(50 is the typical model of its size class)INS-12K-Owith ductless indoor unit INS-12K-I3 of 3 models have all five ratings · AHRI 218620873 |
| Non-ducted, 2 tons | 58.0(50 is the typical model of its size class)INS-24K-Owith ductless indoor unit INS-24K-I1 of 1 models qualify · AHRI 218620875 | 56.1(50 is the typical model of its size class)INS-24K-Owith ductless indoor unit INS-24K-I1 of 1 models have all five ratings · AHRI 218620875 |
| Non-ducted, 2.5–3 tons | 68.0(50 is the typical model of its size class)INM-27K-OAlso listed as INM-27K-O4 of 4 models qualify · AHRI 218620876 | 83.1(50 is the typical model of its size class)INM-27K-OAlso listed as INM-27K-O4 of 4 models have all five ratings · AHRI 218620876 |
Newest INOMA certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| INS-18K-O*INOMA · Ecostarwith ductless indoor unit INS-18K-I | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 99% | 10.0 | 23.5 | CEE 25CEE 26XcelES CC | 1 | 218814800 |
| INM-36K-O*INOMA | 3 tons36,000 Btu/h · Non-ducted | 2.00 | 83% | 10.0 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218718906 |
| INM-27K-O*INOMA | 2.5 tons27,000 Btu/h · Non-ducted | 2.00 | 96% | 10.5 | 26.5 | CEE 25CEE 26XcelES CC | 1 | 218718905 |
| INM-36K-OINOMA · Ecostar | 3 tons36,000 Btu/h · Non-ducted | 2.00 | 83% | 10.0 | 25.0 | CEE 25CEE 26XcelES CC | 1 | 218620877 |
| INM-27K-OINOMA · Ecostar | 2.5 tons27,000 Btu/h · Non-ducted | 2.00 | 96% | 10.5 | 26.5 | CEE 25CEE 26XcelES CC | 1 | 218620876 |
Compare INOMA