- Insights
- Manufacturers
- Keystone
Both views use the same certified data. This device remembers your choice.
Keystone heat pump efficiency: 12 outdoor models compared
Keystone has 12 heat pump outdoor models certified with this refrigerant group, in 12 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Keystone makes. Keystone has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 12
- AHRI certifications
- 12
- Efficiency index
- 47%
- Typical model vs same-size, same-type peers (12 models)
- Meet CEE 2025
- 75%
- 9 models
How Keystone compares with comparable models
- Keystone
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index12 models scored | 47% | Not ranked | — |
| COP at 5°F12 models scored | 33% | Not ranked | 1.80 |
| Capacity retention at 5°F12 models scored | 40% | Not ranked | 72% |
| HSPF212 models scored | 58% | Not ranked | 9.8 |
| SEER212 models scored | 56% | Not ranked | 22.0 |
| EER212 models scored | 47% | Not ranked | 12.3 |
| Heating capacity at 5°F12 models scored | 41% | Not ranked | 8,850 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 75% | 9 |
| CEE 2026 Tier 1 (Split ASHP) | 75% | 9 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 83.3% | 10 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 83.3% | 10 |
Sizes and duct types offered
- Keystone (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 10 | 49% | 36% | 60% | 55% |
| Non-ducted, 2 tons | 2 | 40% | 16% | 47% | 61% |
Every Keystone model in the market
- Keystone models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Keystone models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KYSTNTP12OD2Keystone · Summitwith ductless indoor unit KYSTNTP12ID2 | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 9,100 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 218471056 | Non-ducted, up to 1.5 tons | 61.2 |
| 2KYSTNTP12OD1Keystone · Summitwith ductless indoor unit KYSTNTP12ID1 | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 8,900 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218471054 | Non-ducted, up to 1.5 tons | 60.6 |
| 3KYSTNTV09OD1Keystone · Corewith ductless indoor unit KYSTNTV09ID1 | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.80 | 9.5 | 8,000 | 20.0 | CEE 25CEE 26XcelES CC | 1 | 218471047 | Non-ducted, up to 1.5 tons | 43.9 |
| 4KYSTNTV09OD2Keystone · Corewith ductless indoor unit KYSTNTV09ID2 | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.80 | 9.5 | 8,000 | 21.0 | CEE 25CEE 26XcelES CC | 1 | 218471049 | Non-ducted, up to 1.5 tons | 43.9 |
| 5KYSTNTV12OD1Keystone · Corewith ductless indoor unit KYSTNTV12ID1Also listed as KYSTNTV12OD2 | 1 ton12,000 Btu/h · Non-ducted | 73% | 1.80 | 10.0 | 8,800 | 20.0 | XcelES CC | 1 | 218471048 | Non-ducted, up to 1.5 tons | 43.4 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KYSTNTP12OD2Keystone · Summitwith ductless indoor unit KYSTNTP12ID2 | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 24.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 218471056 | Non-ducted, up to 1.5 tons | 69.5 | 61.2 | 77.8 | 61.2 |
| 2KYSTNTP12OD1Keystone · Summitwith ductless indoor unit KYSTNTP12ID1 | 1 ton12,000 Btu/h · Non-ducted | 72% | 2.10 | 10.0 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 218471054 | Non-ducted, up to 1.5 tons | 66.9 | 60.6 | 73.2 | 60.6 |
| 3KYSTNTP09OD1Keystone · Summitwith ductless indoor unit KYSTNTP09ID1Also listed as KYSTNTP09OD2 | 1 ton9,000 Btu/h · Non-ducted | 71% | 1.90 | 9.5 | 23.0 | 13.0 | CEE 25CEE 26XcelES CC | 1 | 218471053 | Non-ducted, up to 1.5 tons | 57.3 | 41.5 | 73.2 | 41.5 |
| 4KYSTNTP18OD2Keystone · Summitwith ductless indoor unit KYSTNTP18ID2 | 1.5 tons18,000 Btu/h · Non-ducted | 72% | 1.80 | 10.0 | 23.0 | 12.5 | CEE 25CEE 26XcelES CC | 1 | 218471057 | Non-ducted, up to 1.5 tons | 53.6 | 40.8 | 66.4 | 40.8 |
| 5KYSTNTP24OD2Keystone · Summitwith ductless indoor unit KYSTNTP24ID2 | 2 tons23,000 Btu/h · Non-ducted | 74% | 1.80 | 9.5 | 23.0 | 11.7 | CEE 25CEE 26XcelES CC | 1 | 218471058 | Non-ducted, 2 tons | 50.9 | 38.7 | 63.1 | 38.7 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | KYSTNTP12OD1 | 2.10 | Non-ducted, up to 1.5 tons | 78% | 218471054 |
| Capacity retention at 5°F | KYSTNTV09OD1 | 80% | Non-ducted, up to 1.5 tons | 63% | 218471047 |
| HSPF2 | KYSTNTV12OD1Also listed as KYSTNTV12OD2 | 10.0 | Non-ducted, up to 1.5 tons | 66% | 218471048 |
| SEER2 | KYSTNTP24OD2 | 23.0 | Non-ducted, 2 tons | 81% | 218471058 |
| EER2 | KYSTNTP09OD1Also listed as KYSTNTP09OD2 | 13.0 | Non-ducted, up to 1.5 tons | 73% | 218471053 |
| Heating capacity at 5°F | KYSTNTP18OD2 | 13,600 Btu/h | Non-ducted, up to 1.5 tons | 80% | 218471057 |
Keystone size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 61.2(50 is the typical model of its size class)KYSTNTP12OD2with ductless indoor unit KYSTNTP12ID29 of 10 models qualify · AHRI 218471056 | 69.5(50 is the typical model of its size class)KYSTNTP12OD2with ductless indoor unit KYSTNTP12ID210 of 10 models have all five ratings · AHRI 218471056 |
| Non-ducted, 2 tons | 38.7(50 is the typical model of its size class)KYSTNTP24OD2with ductless indoor unit KYSTNTP24ID21 of 2 models qualify · AHRI 218471058 | 50.9(50 is the typical model of its size class)KYSTNTP24OD2with ductless indoor unit KYSTNTP24ID22 of 2 models have all five ratings · AHRI 218471058 |
Newest Keystone certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| KYSTNTP24OD2Keystone · Summitwith ductless indoor unit KYSTNTP24ID2 | 2 tons23,000 Btu/h · Non-ducted | 1.80 | 74% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218471058 |
| KYSTNTP18OD2Keystone · Summitwith ductless indoor unit KYSTNTP18ID2 | 1.5 tons18,000 Btu/h · Non-ducted | 1.80 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218471057 |
| KYSTNTP12OD2Keystone · Summitwith ductless indoor unit KYSTNTP12ID2 | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 24.0 | CEE 25CEE 26XcelES CC | 1 | 218471056 |
| KYSTNTP09OD2Keystone · Summitwith ductless indoor unit KYSTNTP09ID2 | 1 ton9,000 Btu/h · Non-ducted | 1.90 | 71% | 9.5 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218471055 |
| KYSTNTP12OD1Keystone · Summitwith ductless indoor unit KYSTNTP12ID1 | 1 ton12,000 Btu/h · Non-ducted | 2.10 | 72% | 10.0 | 23.0 | CEE 25CEE 26XcelES CC | 1 | 218471054 |
Compare Keystone