KHR heat pump efficiency: 5 outdoor models compared
KHR has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes KHR makes. KHR has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 5
- Efficiency index
- 27%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 100%
- 5 models
How KHR compares with comparable models
- KHR
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 27% | Not ranked | — |
| COP at 5°F5 models scored | 36% | Not ranked | 1.85 |
| Capacity retention at 5°F5 models scored | 23% | Not ranked | 66% |
| HSPF25 models scored | 11% | Not ranked | 8.5 |
| SEER25 models scored | 21% | Not ranked | 19.0 |
| EER25 models scored | 42% | Not ranked | 12.3 |
| Heating capacity at 5°F5 models scored | 28% | Not ranked | 8,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 5 |
| CEE 2026 Tier 1 (Split ASHP) | 80% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 40% | 2 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- KHR (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 5 | 27% | 36% | 11% | 21% |
Every KHR model in the market
- KHR models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top KHR models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KAC-9WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-9GH(E/6)DBP-M100Also listed as KAC-9WH(E1/6)DBP-M100 | 1 ton9,000 Btu/h · Non-ducted | 72% | 1.80 | 8.5 | 6,500 | 19.0 | CEE 25CEE 26Xcel | 1 | 217190051 | Non-ducted, up to 1.5 tons | 21.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1KAC-18WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-18GH(E/6)DBP-M100 | 1.5 tons18,000 Btu/h · Non-ducted | 65% | 2.10 | 8.5 | 19.0 | 12.4 | CEE 25CEE 26 | 1 | 217190050 | Non-ducted, up to 1.5 tons | 35.4 | 34.1 | 36.7 | Not a pick |
| 2KAC-9WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-9GH(E/6)DBP-M100Also listed as KAC-9WH(E1/6)DBP-M100 | 1 ton9,000 Btu/h · Non-ducted | 72% | 1.80 | 8.5 | 19.0 | 12.3 | CEE 25CEE 26Xcel | 1 | 217190051 | Non-ducted, up to 1.5 tons | 29.0 | 21.8 | 36.3 | 21.8 |
| 3KAC-12WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-12GH(E/6)DBP-M100 | 1 ton12,000 Btu/h · Non-ducted | 66% | 1.85 | 8.5 | 19.0 | 10.9 | CEE 25CEE 26 | 1 | 217190048 | Non-ducted, up to 1.5 tons | 21.9 | 19.9 | 24.0 | Not a pick |
| 4KAC-12WH(E1/6)DBP-M100KHRwith ductless indoor unit KAC-12GH(E1/6)DBP-M100 | 1 ton12,000 Btu/h · Non-ducted | 65% | 1.85 | 8.5 | 19.0 | 10.9 | CEE 25 | 1 | 217190049 | Non-ducted, up to 1.5 tons | 21.7 | 19.5 | 24.0 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | KAC-18WH(E/6)DBP-M100 | 2.10 | Non-ducted, up to 1.5 tons | 77% | 217190050 |
| Capacity retention at 5°F | KAC-9WH(E/6)DBP-M100Also listed as KAC-9WH(E1/6)DBP-M100 | 72% | Non-ducted, up to 1.5 tons | 35% | 217190051 |
| HSPF2 | KAC-12WH(E/6)DBP-M100 | 8.5 | Non-ducted, up to 1.5 tons | 11% | 217190048 |
| SEER2 | KAC-12WH(E/6)DBP-M100 | 19.0 | Non-ducted, up to 1.5 tons | 20% | 217190048 |
| EER2 | KAC-18WH(E/6)DBP-M100 | 12.4 | Non-ducted, up to 1.5 tons | 52% | 217190050 |
| Heating capacity at 5°F | KAC-18WH(E/6)DBP-M100 | 12,000 Btu/h | Non-ducted, up to 1.5 tons | 68% | 217190050 |
KHR size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 21.8(50 is the typical model of its size class)KAC-9WH(E/6)DBP-M100with ductless indoor unit KAC-9GH(E/6)DBP-M100Also listed as KAC-9WH(E1/6)DBP-M1002 of 5 models qualify · AHRI 217190051 | 35.4(50 is the typical model of its size class)KAC-18WH(E/6)DBP-M100with ductless indoor unit KAC-18GH(E/6)DBP-M1005 of 5 models have all five ratings · AHRI 217190050 |
Newest KHR certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| KAC-9WH(E1/6)DBP-M100KHRwith ductless indoor unit KAC-9GH(E1/6)DBP-M100 | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 217190052 |
| KAC-9WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-9GH(E/6)DBP-M100 | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 217190051 |
| KAC-18WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-18GH(E/6)DBP-M100 | 1.5 tons18,000 Btu/h · Non-ducted | 2.10 | 65% | 8.5 | 19.0 | CEE 25CEE 26 | 1 | 217190050 |
| KAC-12WH(E1/6)DBP-M100KHRwith ductless indoor unit KAC-12GH(E1/6)DBP-M100 | 1 ton12,000 Btu/h · Non-ducted | 1.85 | 65% | 8.5 | 19.0 | CEE 25 | 1 | 217190049 |
| KAC-12WH(E/6)DBP-M100KHRwith ductless indoor unit KAC-12GH(E/6)DBP-M100 | 1 ton12,000 Btu/h · Non-ducted | 1.85 | 66% | 8.5 | 19.0 | CEE 25CEE 26 | 1 | 217190048 |
Compare KHR