Skip to content

Lithzen heat pump efficiency: 10 outdoor models compared

Lithzen has 10 heat pump outdoor models certified with this refrigerant group, in 10 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Lithzen makes. Lithzen has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
10
AHRI certifications
10
Efficiency index
16%
Typical model vs same-size, same-type peers (6 models)
Meet CEE 2025
20%
2 models

How Lithzen compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Lithzen against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Lithzen’s own modelsLithzen is strongest on COP at 5°F (its typical model beats 33% of comparable models) and weakest on capacity retention at 5°F (2%).
  • Lithzen
  • Middle half of its models
  • Other ranked manufacturers
Lithzen

Source: AHRI Directory, NEEP · as of

Average peer percentile of Lithzen’s models
RatingBeats comparable modelsRankRaw median
Efficiency index6 models scored16%Not ranked—
COP at 5°F6 models scored33%Not ranked1.76
Capacity retention at 5°F6 models scored2%Not ranked52%
HSPF210 models scored3%Not ranked8.2
SEER210 models scored12%Not ranked18.1
EER210 models scored19%Not ranked9.8
Heating capacity at 5°F6 models scored12%Not ranked6,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Lithzen’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Lithzen (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons813%21%4%13%
Non-ducted, 2 tons228%89%3%9%

Every Lithzen model in the market

Lithzen’s 10 models with a known size and duct type, over the shape of the whole catalog.
Lithzen models by size and ratingColoured: Lithzen · grey shapes: all 15,936 models · lines: catalog medians by size
  • Lithzen models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 10 lithzen models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top Lithzen models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No Lithzen model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 4 Lithzen models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1FP11063US-12WHLithzenwith ductless indoor unit FP11063US-22WH/FP11063US-12WH1.5 tons17,100 Btu/h · Non-ducted55%2.228.218.111.6CEE 25CEE 261218029801Non-ducted, up to 1.5 tons29.832.327.3Not a pick
2FP11117US-12WHLithzenwith ductless indoor unit FP11117US-22WH/FP11117US-12WH2 tons23,400 Btu/h · Non-ducted53%2.288.218.111.3CEE 25CEE 261218029802Non-ducted, 2 tons28.131.624.7Not a pick
3FP11116US-12WHLithzenwith ductless indoor unit FP11116US-22WH/FP11116US-12WHAlso listed as FP11303US-12WH1 ton12,000 Btu/h · Non-ducted48%1.678.218.110.8None1218029800Non-ducted, up to 1.5 tons11.81.921.7Not a pick
4FP11062US-12WHLithzenwith ductless indoor unit FP11062US-22WH/FP11062US-12WHAlso listed as FP11302US-12WH1 ton12,100 Btu/h · Non-ducted52%1.768.218.18.8None1218029799Non-ducted, up to 1.5 tons6.75.18.3Not a pick

Best model on each rating

Lithzen’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FFP11063US-12WH2.22Non-ducted, up to 1.5 tons89%218029801
Capacity retention at 5°FFP11063US-12WH55%Non-ducted, up to 1.5 tons4%218029801
HSPF2FP11062US-12WHAlso listed as FP11302US-12WH8.2Non-ducted, up to 1.5 tons4%218029799
SEER2FP11062US-12WHAlso listed as FP11302US-12WH18.1Non-ducted, up to 1.5 tons16%218029799
EER2FP11063US-12WH11.6Non-ducted, up to 1.5 tons39%218029801
Heating capacity at 5°FFP11063US-12WH9,500 Btu/hNon-ducted, up to 1.5 tons54%218029801

All 10 Lithzen models in Explore

Lithzen size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Lithzen: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 8 models qualify)29.8(50 is the typical model of its size class)FP11063US-12WHwith ductless indoor unit FP11063US-22WH/FP11063US-12WH5 of 8 models have all five ratings · AHRI 218029801
Non-ducted, 2 tonsNone on this board (0 of 2 models qualify)28.1(50 is the typical model of its size class)FP11117US-12WHwith ductless indoor unit FP11117US-22WH/FP11117US-12WH1 of 2 models have all five ratings · AHRI 218029802

All-around board, every manufacturer

Newest Lithzen certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified Lithzen outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
FP11274US24K-12WHLITHZENwith ductless indoor unit FP11274US24K-22WH2 tons24,000 Btu/h · Non-ducted——8.017.0None1218461367
FP11274US18K-12WHLITHZENwith ductless indoor unit FP11274US18K-22WH1.5 tons18,000 Btu/h · Non-ducted——8.017.0None1218461366
FP11274US12K-12WHLITHZENwith ductless indoor unit FP11274US12K-22WH1 ton12,000 Btu/h · Non-ducted——8.017.0None1218461365
FP11273US12K-12WHLITHZENwith ductless indoor unit FP11273US12K-22WH1 ton12,000 Btu/h · Non-ducted——8.017.0None1218461364
FP11303US-12WHLithzenwith ductless indoor unit FP11303US-22WH1 ton12,000 Btu/h · Non-ducted1.6748%8.218.1None1218425015

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for Lithzen in this group.

Compare Lithzen

Manufacturers of a similar size, side by side.

Lithzen includes these brand names as listed in AHRI: Lithzen. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter