- Insights
- Manufacturers
- Lithzen
Both views use the same certified data. This device remembers your choice.
Lithzen heat pump efficiency: 10 outdoor models compared
Lithzen has 10 heat pump outdoor models certified with this refrigerant group, in 10 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Lithzen makes. Lithzen has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 10
- AHRI certifications
- 10
- Efficiency index
- 16%
- Typical model vs same-size, same-type peers (6 models)
- Meet CEE 2025
- 20%
- 2 models
How Lithzen compares with comparable models
- Lithzen
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index6 models scored | 16% | Not ranked | — |
| COP at 5°F6 models scored | 33% | Not ranked | 1.76 |
| Capacity retention at 5°F6 models scored | 2% | Not ranked | 52% |
| HSPF210 models scored | 3% | Not ranked | 8.2 |
| SEER210 models scored | 12% | Not ranked | 18.1 |
| EER210 models scored | 19% | Not ranked | 9.8 |
| Heating capacity at 5°F6 models scored | 12% | Not ranked | 6,000 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20% | 2 |
| CEE 2026 Tier 1 (Split ASHP) | 20% | 2 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Lithzen (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 8 | 13% | 21% | 4% | 13% |
| Non-ducted, 2 tons | 2 | 28% | 89% | 3% | 9% |
Every Lithzen model in the market
- Lithzen models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Lithzen models
Cold-climate picks
No Lithzen model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1FP11063US-12WHLithzenwith ductless indoor unit FP11063US-22WH/FP11063US-12WH | 1.5 tons17,100 Btu/h · Non-ducted | 55% | 2.22 | 8.2 | 18.1 | 11.6 | CEE 25CEE 26 | 1 | 218029801 | Non-ducted, up to 1.5 tons | 29.8 | 32.3 | 27.3 | Not a pick |
| 2FP11117US-12WHLithzenwith ductless indoor unit FP11117US-22WH/FP11117US-12WH | 2 tons23,400 Btu/h · Non-ducted | 53% | 2.28 | 8.2 | 18.1 | 11.3 | CEE 25CEE 26 | 1 | 218029802 | Non-ducted, 2 tons | 28.1 | 31.6 | 24.7 | Not a pick |
| 3FP11116US-12WHLithzenwith ductless indoor unit FP11116US-22WH/FP11116US-12WHAlso listed as FP11303US-12WH | 1 ton12,000 Btu/h · Non-ducted | 48% | 1.67 | 8.2 | 18.1 | 10.8 | None | 1 | 218029800 | Non-ducted, up to 1.5 tons | 11.8 | 1.9 | 21.7 | Not a pick |
| 4FP11062US-12WHLithzenwith ductless indoor unit FP11062US-22WH/FP11062US-12WHAlso listed as FP11302US-12WH | 1 ton12,100 Btu/h · Non-ducted | 52% | 1.76 | 8.2 | 18.1 | 8.8 | None | 1 | 218029799 | Non-ducted, up to 1.5 tons | 6.7 | 5.1 | 8.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | FP11063US-12WH | 2.22 | Non-ducted, up to 1.5 tons | 89% | 218029801 |
| Capacity retention at 5°F | FP11063US-12WH | 55% | Non-ducted, up to 1.5 tons | 4% | 218029801 |
| HSPF2 | FP11062US-12WHAlso listed as FP11302US-12WH | 8.2 | Non-ducted, up to 1.5 tons | 4% | 218029799 |
| SEER2 | FP11062US-12WHAlso listed as FP11302US-12WH | 18.1 | Non-ducted, up to 1.5 tons | 16% | 218029799 |
| EER2 | FP11063US-12WH | 11.6 | Non-ducted, up to 1.5 tons | 39% | 218029801 |
| Heating capacity at 5°F | FP11063US-12WH | 9,500 Btu/h | Non-ducted, up to 1.5 tons | 54% | 218029801 |
Lithzen size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 8 models qualify) | 29.8(50 is the typical model of its size class)FP11063US-12WHwith ductless indoor unit FP11063US-22WH/FP11063US-12WH5 of 8 models have all five ratings · AHRI 218029801 |
| Non-ducted, 2 tons | None on this board (0 of 2 models qualify) | 28.1(50 is the typical model of its size class)FP11117US-12WHwith ductless indoor unit FP11117US-22WH/FP11117US-12WH1 of 2 models have all five ratings · AHRI 218029802 |
Newest Lithzen certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| FP11274US24K-12WHLITHZENwith ductless indoor unit FP11274US24K-22WH | 2 tons24,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 218461367 |
| FP11274US18K-12WHLITHZENwith ductless indoor unit FP11274US18K-22WH | 1.5 tons18,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 218461366 |
| FP11274US12K-12WHLITHZENwith ductless indoor unit FP11274US12K-22WH | 1 ton12,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 218461365 |
| FP11273US12K-12WHLITHZENwith ductless indoor unit FP11273US12K-22WH | 1 ton12,000 Btu/h · Non-ducted | — | — | 8.0 | 17.0 | None | 1 | 218461364 |
| FP11303US-12WHLithzenwith ductless indoor unit FP11303US-22WH | 1 ton12,000 Btu/h · Non-ducted | 1.67 | 48% | 8.2 | 18.1 | None | 1 | 218425015 |
Compare Lithzen
Lithzen includes these brand names as listed in AHRI: Lithzen. Standards are checked against published thresholds; program rules beyond ratings are not checked.