Skip to content

LUXCOOL heat pump efficiency: 5 outdoor models compared

LUXCOOL has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LUXCOOL makes. LUXCOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
5
AHRI certifications
5
Efficiency index
21%
Typical model vs same-size, same-type peers (5 models)
Meet CEE 2025
40%
2 models

How LUXCOOL compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
LUXCOOL against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of LUXCOOL’s own modelsLUXCOOL is strongest on COP at 5°F (its typical model beats 57% of comparable models) and weakest on capacity retention at 5°F (3%).
  • LUXCOOL
  • Middle half of its models
  • Other ranked manufacturers
LUXCOOL

Source: AHRI Directory, NEEP · as of

Average peer percentile of LUXCOOL’s models
RatingBeats comparable modelsRankRaw median
Efficiency index5 models scored21%Not ranked—
COP at 5°F5 models scored57%Not ranked2.22
Capacity retention at 5°F5 models scored3%Not ranked53%
HSPF25 models scored4%Not ranked8.2
SEER25 models scored14%Not ranked18.1
EER25 models scored25%Not ranked10.8
Heating capacity at 5°F5 models scored18%Not ranked9,500 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
LUXCOOL’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • LUXCOOL (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons316%33%4%16%
Non-ducted, 2 tons128%89%4%13%
Non-ducted, 2.5 to 3 tons126%99%5%10%

Every LUXCOOL model in the market

LUXCOOL’s 5 models with a known size and duct type, over the shape of the whole catalog.
LUXCOOL models by size and ratingColoured: LUXCOOL · grey shapes: all 15,909 models · lines: catalog medians by size
  • LUXCOOL models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 5 luxcool models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,909 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8871.641.711.751.852.24
Ducted, 1 ton4591.801.872.002.412.44
Ducted, 1.5 tons1,0291.751.832.002.202.40
Ducted, 2 tons1,0711.751.862.002.182.30
Ducted, 2.5 tons1,1341.701.802.002.102.35
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7671.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3831.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4811.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2131.961.972.052.102.11
Non-ducted, 4.5 tons811.901.911.972.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top LUXCOOL models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No LUXCOOL model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 5 LUXCOOL models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1LUX-18CVA-OLUXCOOLwith ductless indoor unit LUX-18CVA-I1.5 tons17,100 Btu/h · Non-ducted55%2.228.218.111.6CEE 25CEE 261218696678Non-ducted, up to 1.5 tons29.832.327.3Not a pick
2LUX-24CVA-OLUXCOOLwith ductless indoor unit LUX-24CVA-I2 tons23,400 Btu/h · Non-ducted53%2.288.218.111.3CEE 25CEE 261218696679Non-ducted, 2 tons28.131.624.7Not a pick
3LUX-36CVA-OLUXCOOLwith ductless indoor unit LUX-36CVA-I3 tons34,600 Btu/h · Non-ducted59%2.448.218.19.6None1218696680Non-ducted, 2.5 to 3 tons26.037.015.0Not a pick
4LUX-12CVA2-OLUXCOOLwith ductless indoor unit LUX-12CVA2-I1 ton12,000 Btu/h · Non-ducted48%1.678.218.110.8None1218696677Non-ducted, up to 1.5 tons11.81.921.7Not a pick
5LUX-12CVA-OLUXCOOLwith ductless indoor unit LUX-12CVA-I1 ton12,100 Btu/h · Non-ducted52%1.768.218.18.8None1218696676Non-ducted, up to 1.5 tons6.75.18.3Not a pick

Best model on each rating

LUXCOOL’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FLUX-36CVA-O2.44Non-ducted, 2.5 to 3 tons99%218696680
Capacity retention at 5°FLUX-36CVA-O59%Non-ducted, 2.5 to 3 tons8%218696680
HSPF2LUX-12CVA-O8.2Non-ducted, up to 1.5 tons4%218696676
SEER2LUX-12CVA-O18.1Non-ducted, up to 1.5 tons16%218696676
EER2LUX-18CVA-O11.6Non-ducted, up to 1.5 tons39%218696678
Heating capacity at 5°FLUX-18CVA-O9,500 Btu/hNon-ducted, up to 1.5 tons54%218696678

All 5 LUXCOOL models in Explore

LUXCOOL size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
LUXCOOL: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)29.8(50 is the typical model of its size class)LUX-18CVA-Owith ductless indoor unit LUX-18CVA-I3 of 3 models have all five ratings · AHRI 218696678
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)28.1(50 is the typical model of its size class)LUX-24CVA-Owith ductless indoor unit LUX-24CVA-I1 of 1 models have all five ratings · AHRI 218696679
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)26.0(50 is the typical model of its size class)LUX-36CVA-Owith ductless indoor unit LUX-36CVA-I1 of 1 models have all five ratings · AHRI 218696680

All-around board, every manufacturer

Newest LUXCOOL certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified LUXCOOL outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
LUX-36CVA-OLUXCOOLwith ductless indoor unit LUX-36CVA-I3 tons34,600 Btu/h · Non-ducted2.4459%8.218.1None1218696680
LUX-24CVA-OLUXCOOLwith ductless indoor unit LUX-24CVA-I2 tons23,400 Btu/h · Non-ducted2.2853%8.218.1CEE 25CEE 261218696679
LUX-18CVA-OLUXCOOLwith ductless indoor unit LUX-18CVA-I1.5 tons17,100 Btu/h · Non-ducted2.2255%8.218.1CEE 25CEE 261218696678
LUX-12CVA2-OLUXCOOLwith ductless indoor unit LUX-12CVA2-I1 ton12,000 Btu/h · Non-ducted1.6748%8.218.1None1218696677
LUX-12CVA-OLUXCOOLwith ductless indoor unit LUX-12CVA-I1 ton12,100 Btu/h · Non-ducted1.7652%8.218.1None1218696676

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for LUXCOOL in this group.

Compare LUXCOOL

Manufacturers of a similar size, side by side.

LUXCOOL includes these brand names as listed in AHRI: LUXCOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter