- Insights
- Manufacturers
- LUXCOOL
Both views use the same certified data. This device remembers your choice.
LUXCOOL heat pump efficiency: 5 outdoor models compared
LUXCOOL has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes LUXCOOL makes. LUXCOOL has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 5
- Efficiency index
- 21%
- Typical model vs same-size, same-type peers (5 models)
- Meet CEE 2025
- 40%
- 2 models
How LUXCOOL compares with comparable models
- LUXCOOL
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index5 models scored | 21% | Not ranked | — |
| COP at 5°F5 models scored | 57% | Not ranked | 2.22 |
| Capacity retention at 5°F5 models scored | 3% | Not ranked | 53% |
| HSPF25 models scored | 4% | Not ranked | 8.2 |
| SEER25 models scored | 14% | Not ranked | 18.1 |
| EER25 models scored | 25% | Not ranked | 10.8 |
| Heating capacity at 5°F5 models scored | 18% | Not ranked | 9,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 40% | 2 |
| CEE 2026 Tier 1 (Split ASHP) | 40% | 2 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- LUXCOOL (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 3 | 16% | 33% | 4% | 16% |
| Non-ducted, 2 tons | 1 | 28% | 89% | 4% | 13% |
| Non-ducted, 2.5 to 3 tons | 1 | 26% | 99% | 5% | 10% |
Every LUXCOOL model in the market
- LUXCOOL models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 887 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 459 | 1.80 | 1.87 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,029 | 1.75 | 1.83 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,071 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,134 | 1.70 | 1.80 | 2.00 | 2.10 | 2.35 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 767 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,383 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,481 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 213 | 1.96 | 1.97 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 81 | 1.90 | 1.91 | 1.97 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top LUXCOOL models
Cold-climate picks
No LUXCOOL model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1LUX-18CVA-OLUXCOOLwith ductless indoor unit LUX-18CVA-I | 1.5 tons17,100 Btu/h · Non-ducted | 55% | 2.22 | 8.2 | 18.1 | 11.6 | CEE 25CEE 26 | 1 | 218696678 | Non-ducted, up to 1.5 tons | 29.8 | 32.3 | 27.3 | Not a pick |
| 2LUX-24CVA-OLUXCOOLwith ductless indoor unit LUX-24CVA-I | 2 tons23,400 Btu/h · Non-ducted | 53% | 2.28 | 8.2 | 18.1 | 11.3 | CEE 25CEE 26 | 1 | 218696679 | Non-ducted, 2 tons | 28.1 | 31.6 | 24.7 | Not a pick |
| 3LUX-36CVA-OLUXCOOLwith ductless indoor unit LUX-36CVA-I | 3 tons34,600 Btu/h · Non-ducted | 59% | 2.44 | 8.2 | 18.1 | 9.6 | None | 1 | 218696680 | Non-ducted, 2.5 to 3 tons | 26.0 | 37.0 | 15.0 | Not a pick |
| 4LUX-12CVA2-OLUXCOOLwith ductless indoor unit LUX-12CVA2-I | 1 ton12,000 Btu/h · Non-ducted | 48% | 1.67 | 8.2 | 18.1 | 10.8 | None | 1 | 218696677 | Non-ducted, up to 1.5 tons | 11.8 | 1.9 | 21.7 | Not a pick |
| 5LUX-12CVA-OLUXCOOLwith ductless indoor unit LUX-12CVA-I | 1 ton12,100 Btu/h · Non-ducted | 52% | 1.76 | 8.2 | 18.1 | 8.8 | None | 1 | 218696676 | Non-ducted, up to 1.5 tons | 6.7 | 5.1 | 8.3 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | LUX-36CVA-O | 2.44 | Non-ducted, 2.5 to 3 tons | 99% | 218696680 |
| Capacity retention at 5°F | LUX-36CVA-O | 59% | Non-ducted, 2.5 to 3 tons | 8% | 218696680 |
| HSPF2 | LUX-12CVA-O | 8.2 | Non-ducted, up to 1.5 tons | 4% | 218696676 |
| SEER2 | LUX-12CVA-O | 18.1 | Non-ducted, up to 1.5 tons | 16% | 218696676 |
| EER2 | LUX-18CVA-O | 11.6 | Non-ducted, up to 1.5 tons | 39% | 218696678 |
| Heating capacity at 5°F | LUX-18CVA-O | 9,500 Btu/h | Non-ducted, up to 1.5 tons | 54% | 218696678 |
LUXCOOL size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 29.8(50 is the typical model of its size class)LUX-18CVA-Owith ductless indoor unit LUX-18CVA-I3 of 3 models have all five ratings · AHRI 218696678 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | 28.1(50 is the typical model of its size class)LUX-24CVA-Owith ductless indoor unit LUX-24CVA-I1 of 1 models have all five ratings · AHRI 218696679 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | 26.0(50 is the typical model of its size class)LUX-36CVA-Owith ductless indoor unit LUX-36CVA-I1 of 1 models have all five ratings · AHRI 218696680 |
Newest LUXCOOL certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| LUX-36CVA-OLUXCOOLwith ductless indoor unit LUX-36CVA-I | 3 tons34,600 Btu/h · Non-ducted | 2.44 | 59% | 8.2 | 18.1 | None | 1 | 218696680 |
| LUX-24CVA-OLUXCOOLwith ductless indoor unit LUX-24CVA-I | 2 tons23,400 Btu/h · Non-ducted | 2.28 | 53% | 8.2 | 18.1 | CEE 25CEE 26 | 1 | 218696679 |
| LUX-18CVA-OLUXCOOLwith ductless indoor unit LUX-18CVA-I | 1.5 tons17,100 Btu/h · Non-ducted | 2.22 | 55% | 8.2 | 18.1 | CEE 25CEE 26 | 1 | 218696678 |
| LUX-12CVA2-OLUXCOOLwith ductless indoor unit LUX-12CVA2-I | 1 ton12,000 Btu/h · Non-ducted | 1.67 | 48% | 8.2 | 18.1 | None | 1 | 218696677 |
| LUX-12CVA-OLUXCOOLwith ductless indoor unit LUX-12CVA-I | 1 ton12,100 Btu/h · Non-ducted | 1.76 | 52% | 8.2 | 18.1 | None | 1 | 218696676 |
Compare LUXCOOL
LUXCOOL includes these brand names as listed in AHRI: LUXCOOL. Standards are checked against published thresholds; program rules beyond ratings are not checked.