- Insights
- Manufacturers
- Maestro
Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Maestro heat pump efficiency: 5 outdoor models compared
Maestro has 5 heat pump outdoor models certified with this refrigerant group, in 5 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Maestro makes. Maestro has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 5
- AHRI certifications
- 5
- Efficiency index
- 7%
- Typical model vs same-size, same-type peers (3 models)
- Meet CEE 2025
- 0%
- 0 models
How Maestro compares with comparable models
- Maestro
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index3 models scored | 7% | Not ranked | — |
| COP at 5°F5 models scored | 5% | Not ranked | 1.76 |
| Capacity retention at 5°F3 models scored | 2% | Not ranked | 55% |
| HSPF25 models scored | 1% | Not ranked | 6.7 |
| SEER25 models scored | 1% | Not ranked | 15.0 |
| EER25 models scored | 21% | Not ranked | 10.6 |
| Heating capacity at 5°F3 models scored | 1% | Not ranked | 4,100 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0% | 0 |
| CEE 2026 Tier 1 (Split ASHP) | 0% | 0 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0% | 0 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Maestro (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 2 | — | 1% | 3% | 2% |
| Non-ducted, up to 1.5 tons | 3 | 7% | 9% | 0% | 0% |
Every Maestro model in the market
- Maestro models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Maestro models
Cold-climate picks
No Maestro model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 12451Maestro | 0.5 tons7,200 Btu/h · Non-ducted | 55% | 1.76 | 6.7 | 15.0 | 10.6 | None | 1 | 214784010 | Non-ducted, up to 1.5 tons | 7.8 | 3.4 | 12.2 | Not a pick |
| 22450MaestroAlso listed as 2452 | 0.5 tons7,600 Btu/h · Non-ducted | 55% | 1.77 | 6.7 | 15.0 | 10.2 | None | 1 | 214784009 | Non-ducted, up to 1.5 tons | 6.2 | 3.5 | 9.0 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | 2450Also listed as 2452 | 1.77 | Non-ducted, up to 1.5 tons | 9% | 214784009 |
| Capacity retention at 5°F | 2451 | 55% | Non-ducted, up to 1.5 tons | 2% | 214784010 |
| HSPF2 | 2476Also listed as 2475 | 6.7 | Ducted, up to 1.5 tons | 3% | 215399289 |
| SEER2 | 2476Also listed as 2475 | 13.5 | Ducted, up to 1.5 tons | 2% | 215399289 |
| EER2 | 2451 | 10.6 | Non-ducted, up to 1.5 tons | 24% | 214784010 |
| Heating capacity at 5°F | 2450Also listed as 2452 | 4,100 Btu/h | Non-ducted, up to 1.5 tons | 1% | 214784009 |
Maestro size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 2 models have all five ratings) |
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | 7.8(50 is the typical model of its size class)24513 of 3 models have all five ratings · AHRI 214784010 |
Newest Maestro certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| 2475Maestro | 0.5 tons7,900 Btu/h · Ducted | 1.50 | — | 6.7 | 13.5 | None | 1 | 215399290 |
| 2476Maestro | 0.5 tons7,900 Btu/h · Ducted | 1.50 | — | 6.7 | 13.5 | None | 1 | 215399289 |
| 2452Maestro | 0.5 tons7,600 Btu/h · Non-ducted | 1.77 | 55% | 6.7 | 15.0 | None | 1 | 214784011 |
| 2451Maestro | 0.5 tons7,200 Btu/h · Non-ducted | 1.76 | 55% | 6.7 | 15.0 | None | 1 | 214784010 |
| 2450Maestro | 0.5 tons7,600 Btu/h · Non-ducted | 1.77 | 55% | 6.7 | 15.0 | None | 1 | 214784009 |
Compare Maestro