Skip to content

MapleTemp heat pump efficiency: 4 outdoor models compared

MapleTemp has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MapleTemp makes. MapleTemp has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
73%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How MapleTemp compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
MapleTemp against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of MapleTemp’s own modelsMapleTemp is strongest on SEER2 (its typical model beats 85% of comparable models) and weakest on capacity retention at 5°F (58%).
  • MapleTemp
  • Middle half of its models
  • Other ranked manufacturers
MapleTemp

Source: AHRI Directory, NEEP · as of

Average peer percentile of MapleTemp’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored73%Not ranked—
COP at 5°F4 models scored79%Not ranked2.10
Capacity retention at 5°F4 models scored58%Not ranked79%
HSPF24 models scored74%Not ranked10.3
SEER24 models scored85%Not ranked24.5
EER24 models scored67%Not ranked13.0
Heating capacity at 5°F4 models scored62%Not ranked12,150 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
MapleTemp’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • MapleTemp (median, middle 50%, 10th–90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons369%81%71%82%
Non-ducted, 2 tons187%71%85%95%

Every MapleTemp model in the market

MapleTemp’s 4 models with a known size and duct type, over the shape of the whole catalog.
MapleTemp models by size and ratingColoured: MapleTemp · grey shapes: all 14,508 models · lines: catalog medians by size
  • MapleTemp models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 mapletemp models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top MapleTemp models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 MapleTemp cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1MTH25-18K220V/OMapleTempwith ductless indoor unit MTH25-18K220V/I1.5 tons18,000 Btu/h · Non-ducted82%2.2510.515,00025.0CEE 25CEE 26Xcel1218327183Non-ducted, up to 1.5 tons79.3
2MTH25-24K220V/OMapleTempwith ductless indoor unit MTH25-24K220V/I2 tons22,400 Btu/h · Non-ducted85%2.1010.520,40025.0CEE 25CEE 26Xcel1218327184Non-ducted, 2 tons77.4
3MTH24-12K115V/OMapleTempwith ductless indoor unit MTH24-12K115V/I1 ton12,000 Btu/h · Non-ducted76%2.1010.09,30024.0CEE 25CEE 26Xcel1218327181Non-ducted, up to 1.5 tons64.1
4MTH24-12K220V/OMapleTempwith ductless indoor unit MTH24-12K220V/I1 ton12,000 Btu/h · Non-ducted72%2.1010.08,90024.0CEE 25CEE 26Xcel1218327182Non-ducted, up to 1.5 tons60.0

All-around best

Top 4 MapleTemp models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1MTH25-24K220V/OMapleTempwith ductless indoor unit MTH25-24K220V/I2 tons22,400 Btu/h · Non-ducted85%2.1010.525.014.0CEE 25CEE 26Xcel1218327184Non-ducted, 2 tons86.577.495.677.4
2MTH25-18K220V/OMapleTempwith ductless indoor unit MTH25-18K220V/I1.5 tons18,000 Btu/h · Non-ducted82%2.2510.525.014.0CEE 25CEE 26Xcel1218327183Non-ducted, up to 1.5 tons83.079.386.779.3
3MTH24-12K115V/OMapleTempwith ductless indoor unit MTH24-12K115V/I1 ton12,000 Btu/h · Non-ducted76%2.1010.024.012.0CEE 25CEE 26Xcel1218327181Non-ducted, up to 1.5 tons62.864.161.564.1
4MTH24-12K220V/OMapleTempwith ductless indoor unit MTH24-12K220V/I1 ton12,000 Btu/h · Non-ducted72%2.1010.024.012.0CEE 25CEE 26Xcel1218327182Non-ducted, up to 1.5 tons60.760.061.560.0

Best model on each rating

MapleTemp’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FMTH25-18K220V/O2.25Non-ducted, up to 1.5 tons89%218327183
Capacity retention at 5°FMTH25-24K220V/O85%Non-ducted, 2 tons73%218327184
HSPF2MTH25-24K220V/O10.5Non-ducted, 2 tons84%218327184
SEER2MTH25-24K220V/O25.0Non-ducted, 2 tons95%218327184
EER2MTH25-24K220V/O14.0Non-ducted, 2 tons96%218327184
Heating capacity at 5°FMTH25-18K220V/O15,000 Btu/hNon-ducted, up to 1.5 tons86%218327183

All 4 MapleTemp models in Explore

MapleTemp size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
MapleTemp: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons79.3(50 is the typical model of its size class)MTH25-18K220V/Owith ductless indoor unit MTH25-18K220V/I3 of 3 models qualify · AHRI 21832718383.0(50 is the typical model of its size class)MTH25-18K220V/Owith ductless indoor unit MTH25-18K220V/I3 of 3 models have all five ratings · AHRI 218327183
Non-ducted, 2 tons77.4(50 is the typical model of its size class)MTH25-24K220V/Owith ductless indoor unit MTH25-24K220V/I1 of 1 models qualify · AHRI 21832718486.5(50 is the typical model of its size class)MTH25-24K220V/Owith ductless indoor unit MTH25-24K220V/I1 of 1 models have all five ratings · AHRI 218327184

All-around board, every manufacturer

Newest MapleTemp certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified MapleTemp outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
MTH25-24K220V/OMapleTempwith ductless indoor unit MTH25-24K220V/I2 tons22,400 Btu/h · Non-ducted2.1085%10.525.0CEE 25CEE 26Xcel1218327184
MTH25-18K220V/OMapleTempwith ductless indoor unit MTH25-18K220V/I1.5 tons18,000 Btu/h · Non-ducted2.2582%10.525.0CEE 25CEE 26Xcel1218327183
MTH24-12K220V/OMapleTempwith ductless indoor unit MTH24-12K220V/I1 ton12,000 Btu/h · Non-ducted2.1072%10.024.0CEE 25CEE 26Xcel1218327182
MTH24-12K115V/OMapleTempwith ductless indoor unit MTH24-12K115V/I1 ton12,000 Btu/h · Non-ducted2.1076%10.024.0CEE 25CEE 26Xcel1218327181

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for MapleTemp in this group.

Compare MapleTemp

Manufacturers of a similar size, side by side.

MapleTemp includes these brand names as listed in AHRI: MapleTemp. Standards are checked against published thresholds; program rules beyond ratings are not checked.