Skip to content

MBO heat pump efficiency: 9 outdoor models compared

MBO has 9 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes MBO makes. MBO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
9
AHRI certifications
9
Efficiency index
23%
Typical model vs same-size, same-type peers (9 models)
Meet CEE 2025
44.4%
4 models

How MBO compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
MBO against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of MBO’s own modelsMBO is strongest on COP at 5°F (its typical model beats 39% of comparable models) and weakest on capacity retention at 5°F (3%).
  • MBO
  • Middle half of its models
  • Other ranked manufacturers
MBO

Source: AHRI Directory, NEEP · as of

Average peer percentile of MBO’s models
RatingBeats comparable modelsRankRaw median
Efficiency index9 models scored23%Not ranked—
COP at 5°F9 models scored39%Not ranked1.77
Capacity retention at 5°F9 models scored3%Not ranked52%
HSPF29 models scored7%Not ranked8.2
SEER29 models scored26%Not ranked18.1
EER29 models scored35%Not ranked10.8
Heating capacity at 5°F9 models scored17%Not ranked6,400 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
MBO’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • MBO (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons722%23%8%30%
Non-ducted, 2 tons128%89%4%13%
Non-ducted, 2.5 to 3 tons126%99%5%10%

Every MBO model in the market

MBO’s 9 models with a known size and duct type, over the shape of the whole catalog.
MBO models by size and ratingColoured: MBO · grey shapes: all 15,936 models · lines: catalog medians by size
  • MBO models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 9 mbo models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top MBO models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

No MBO model keeps at least 70% of its heat at 5°F with all three cold-climate ratings.

All-around best

Top 5 MBO models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1MSAW-18HVCMMBO · MSA-18HVCMwith ductless indoor unit MSAG-18HVCM1.5 tons18,500 Btu/h · Non-ducted53%1.918.921.213.2CEE 25CEE 261218393600Non-ducted, up to 1.5 tons45.825.865.8Not a pick
2MSBW-12HVCNMBO · MSB-12HVCNwith ductless indoor unit MSBG-12HVCN1 ton12,000 Btu/h · Non-ducted50%1.778.323.913.1CEE 25CEE 261218393599Non-ducted, up to 1.5 tons42.35.479.3Not a pick
3MSAW-18HVCF.1MBO · MSA-18HVCF.1*with ductless indoor unit MSAG18HVCF.11.5 tons17,100 Btu/h · Non-ducted55%2.228.218.111.6CEE 25CEE 261217549993Non-ducted, up to 1.5 tons29.832.327.3Not a pick
4MSAW-24HVCF.1MBO · MSA-24HVCF.1*with ductless indoor unit MSAG-24HVCF.12 tons23,400 Btu/h · Non-ducted53%2.288.218.111.3CEE 25CEE 261217549994Non-ducted, 2 tons28.131.624.7Not a pick
5MSAW-36HVCFMBO · MSA-36HVCF*with ductless indoor unit MSAG-36HVCF3 tons34,600 Btu/h · Non-ducted59%2.448.218.19.6None1217549995Non-ducted, 2.5 to 3 tons26.037.015.0Not a pick

Best model on each rating

MBO’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FMSAW-36HVCF2.44Non-ducted, 2.5 to 3 tons99%217549995
Capacity retention at 5°FMSAW-36HVCF59%Non-ducted, 2.5 to 3 tons8%217549995
HSPF2MSAW-18HVCM8.9Non-ducted, up to 1.5 tons26%218393600
SEER2MSBW-12HVCN23.9Non-ducted, up to 1.5 tons74%218393599
EER2MSAW-18HVCM13.2Non-ducted, up to 1.5 tons78%218393600
Heating capacity at 5°FMSAW-18HVCM10,100 Btu/hNon-ducted, up to 1.5 tons59%218393600

All 9 MBO models in Explore

MBO size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
MBO: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 7 models qualify)45.8(50 is the typical model of its size class)MSAW-18HVCMwith ductless indoor unit MSAG-18HVCM7 of 7 models have all five ratings · AHRI 218393600
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)28.1(50 is the typical model of its size class)MSAW-24HVCF.1with ductless indoor unit MSAG-24HVCF.11 of 1 models have all five ratings · AHRI 217549994
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)26.0(50 is the typical model of its size class)MSAW-36HVCFwith ductless indoor unit MSAG-36HVCF1 of 1 models have all five ratings · AHRI 217549995

All-around board, every manufacturer

Newest MBO certifications

By AHRI reference number; AHRI issues references in increasing order.
The 5 most recently certified MBO outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
MSAW-18HVCMMBO · MSA-18HVCMwith ductless indoor unit MSAG-18HVCM1.5 tons18,500 Btu/h · Non-ducted1.9153%8.921.2CEE 25CEE 261218393600
MSBW-12HVCNMBO · MSB-12HVCNwith ductless indoor unit MSBG-12HVCN1 ton12,000 Btu/h · Non-ducted1.7750%8.323.9CEE 25CEE 261218393599
MSAW-36HVCFMBO · MSA-36HVCF*with ductless indoor unit MSAG-36HVCF3 tons34,600 Btu/h · Non-ducted2.4459%8.218.1None1217549995
MSAW-24HVCF.1MBO · MSA-24HVCF.1*with ductless indoor unit MSAG-24HVCF.12 tons23,400 Btu/h · Non-ducted2.2853%8.218.1CEE 25CEE 261217549994
MSAW-18HVCF.1MBO · MSA-18HVCF.1*with ductless indoor unit MSAG18HVCF.11.5 tons17,100 Btu/h · Non-ducted2.2255%8.218.1CEE 25CEE 261217549993

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for MBO in this group.

Compare MBO

Manufacturers of a similar size, side by side.

MBO includes these brand names as listed in AHRI: MBO. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter