Rellytech heat pump efficiency: 38 outdoor models compared
Rellytech has 38 heat pump outdoor models certified with this refrigerant group, in 38 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Rellytech makes. Rellytech has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 38
- AHRI certifications
- 38
- Efficiency index
- 33%
- Typical model vs same-size, same-type peers (38 models)
- Meet CEE 2025
- 63.2%
- 24 models
How Rellytech compares with comparable models
- Rellytech
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index38 models scored | 33% | Not ranked | — |
| COP at 5°F38 models scored | 36% | Not ranked | 1.80 |
| Capacity retention at 5°F38 models scored | 31% | Not ranked | 70% |
| HSPF238 models scored | 43% | Not ranked | 9.5 |
| SEER238 models scored | 31% | Not ranked | 20.0 |
| EER238 models scored | 27% | Not ranked | 10.5 |
| Heating capacity at 5°F38 models scored | 38% | Not ranked | 9,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 63.2% | 24 |
| CEE 2026 Tier 1 (Split ASHP) | 60.5% | 23 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 50% | 19 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- Rellytech (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Non-ducted, up to 1.5 tons | 27 | 34% | 32% | 45% | 32% |
| Non-ducted, 2 tons | 5 | 28% | 38% | 46% | 30% |
| Non-ducted, 2.5–3 tons | 5 | 30% | 57% | 32% | 25% |
| Non-ducted, 3.5–4.5 tons | 1 | 27% | 37% | 14% | 29% |
Every Rellytech model in the market
- Rellytech models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 883 | 1.64 | 1.71 | 1.75 | 1.85 | 2.23 |
| Ducted, 1 ton | 452 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,016 | 1.75 | 1.83 | 2.00 | 2.19 | 2.40 |
| Ducted, 2 tons | 1,054 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,122 | 1.70 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 3 tons | 725 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 889 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 750 | 1.80 | 1.85 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 713 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 90 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,358 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,579 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,451 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 845 | 1.80 | 2.00 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 446 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 511 | 1.80 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 298 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 211 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 87 | 1.99 | 2.03 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Rellytech models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1T20230W20E12RellytechAlso listed as T18230W20 | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 16,000 | 24.0 | CEE 25CEE 26Xcel | 1 | 217933638 | Non-ducted, up to 1.5 tons | 70.0 |
| 2A09230W20E12Rellytechwith ductless indoor unit A09230N20E12Also listed as A09230W20822 | 1 ton9,000 Btu/h · Non-ducted | 74% | 1.90 | 10.0 | 7,400 | 20.0 | CEE 25CEE 26Xcel | 1 | 217933635 | Non-ducted, up to 1.5 tons | 52.3 |
| 3T28230W20E11Rellytech | 2.5 tons28,000 Btu/h · Non-ducted | 75% | 2.00 | 9.5 | 21,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 218088496 | Non-ducted, 2.5–3 tons | 48.4 |
| 4T36230W20E11Rellytech | 3 tons38,000 Btu/h · Non-ducted | 74% | 2.00 | 9.5 | 31,000 | 20.0 | CEE 25CEE 26Xcel | 1 | 218088497 | Non-ducted, 2.5–3 tons | 47.4 |
| 5T20230W20E11Rellytech | 1.5 tons20,000 Btu/h · Non-ducted | 70% | 2.00 | 9.5 | 14,000 | 23.0 | CEE 25CEE 26Xcel | 1 | 218088495 | Non-ducted, up to 1.5 tons | 46.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1T20230W20E12RellytechAlso listed as T18230W20 | 1.5 tons18,000 Btu/h · Non-ducted | 80% | 2.00 | 10.5 | 24.0 | 13.0 | CEE 25CEE 26Xcel | 1 | 217933638 | Non-ducted, up to 1.5 tons | 73.8 | 70.0 | 77.7 | 70.0 |
| 2T20230W20E11Rellytech | 1.5 tons20,000 Btu/h · Non-ducted | 70% | 2.00 | 9.5 | 23.0 | 11.2 | CEE 25CEE 26Xcel | 1 | 218088495 | Non-ducted, up to 1.5 tons | 49.3 | 46.2 | 52.4 | 46.2 |
| 3A09230W20E11Rellytechwith ductless indoor unit A09230N20E11 | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.80 | 9.5 | 21.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 218085955 | Non-ducted, up to 1.5 tons | 48.8 | 43.9 | 53.7 | 43.9 |
| 4A09230W20E12Rellytechwith ductless indoor unit A09230N20E12Also listed as A09230W20822 | 1 ton9,000 Btu/h · Non-ducted | 74% | 1.90 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 217933635 | Non-ducted, up to 1.5 tons | 46.1 | 52.3 | 39.8 | 52.3 |
| 5A09115W20E11Rellytechwith ductless indoor unit A09115N20E11 | 1 ton9,000 Btu/h · Non-ducted | 80% | 1.80 | 9.5 | 20.0 | 12.0 | CEE 25CEE 26Xcel | 1 | 218085953 | Non-ducted, up to 1.5 tons | 41.8 | 43.9 | 39.8 | 43.9 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | A36230W20E12Also listed as A36230W20822 | 2.10 | Non-ducted, 2.5–3 tons | 87% | 217933670 |
| Capacity retention at 5°F | T20230W20E12Also listed as T18230W20 | 80% | Non-ducted, up to 1.5 tons | 63% | 217933638 |
| HSPF2 | T20230W20E12Also listed as T18230W20 | 10.5 | Non-ducted, up to 1.5 tons | 81% | 217933638 |
| SEER2 | T20230W20E12Also listed as T18230W20 | 24.0 | Non-ducted, up to 1.5 tons | 77% | 217933638 |
| EER2 | T20230W20E12Also listed as T18230W20 | 13.0 | Non-ducted, up to 1.5 tons | 72% | 217933638 |
| Heating capacity at 5°F | T20230W20E12Also listed as T18230W20 | 16,000 Btu/h | Non-ducted, up to 1.5 tons | 89% | 217933638 |
Rellytech size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 70.0(50 is the typical model of its size class)T20230W20E12Also listed as T18230W2016 of 27 models qualify · AHRI 217933638 | 73.8(50 is the typical model of its size class)T20230W20E12Also listed as T18230W2027 of 27 models have all five ratings · AHRI 217933638 |
| Non-ducted, 2 tons | None on this board (0 of 5 models qualify) | 41.0(50 is the typical model of its size class)A24230W20E12with ductless indoor unit A24230N20E12Also listed as A24230W208225 of 5 models have all five ratings · AHRI 217933669 |
| Non-ducted, 2.5–3 tons | 48.4(50 is the typical model of its size class)T28230W20E112 of 5 models qualify · AHRI 218088496 | 39.9(50 is the typical model of its size class)T28230W20E115 of 5 models have all five ratings · AHRI 218088496 |
| Non-ducted, 3.5–4.5 tons | 24.6(50 is the typical model of its size class)T42230W20E111 of 1 models qualify · AHRI 218088498 | 26.9(50 is the typical model of its size class)T42230W20E111 of 1 models have all five ratings · AHRI 218088498 |
Newest Rellytech certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| A18W00000523Rellytechwith ductless indoor unit A18N00000339 | 1.5 tons18,000 Btu/h · Non-ducted | 2.10 | 65% | 8.5 | 19.0 | CEE 25CEE 26 | 1 | 218139638 |
| A12W00000521Rellytechwith ductless indoor unit A12N00000337 | 1 ton12,000 Btu/h · Non-ducted | 1.85 | 65% | 8.5 | 19.0 | CEE 25 | 1 | 218139637 |
| A09W00000549Rellytechwith ductless indoor unit A09N00000365 | 1 ton9,000 Btu/h · Non-ducted | 1.80 | 72% | 8.5 | 19.0 | CEE 25CEE 26Xcel | 1 | 218139636 |
| T42230W20E11Rellytech | 3.5 tons42,000 Btu/h · Non-ducted | 2.00 | 74% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 218088498 |
| T36230W20E11Rellytech | 3 tons38,000 Btu/h · Non-ducted | 2.00 | 74% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 218088497 |
Compare Rellytech
Rellytech includes these brand names as listed in AHRI: Rellytech. Standards are checked against published thresholds; program rules beyond ratings are not checked.