SINCLAIR AIR CONDITIONING heat pump efficiency: 9 outdoor models compared
SINCLAIR AIR CONDITIONING has 9 heat pump outdoor models certified with this refrigerant group, in 1,150 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes SINCLAIR AIR CONDITIONING makes. SINCLAIR AIR CONDITIONING has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 9
- AHRI certifications
- 1,150
- Efficiency index
- 55%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 33.3%
- 3 models
How SINCLAIR AIR CONDITIONING compares with comparable models
- SINCLAIR AIR CONDITIONING
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 55% | Not ranked | — |
| COP at 5°F9 models scored | 78% | Not ranked | 2.18 |
| Capacity retention at 5°F9 models scored | 25% | Not ranked | 52% |
| HSPF29 models scored | 46% | Not ranked | 8.1 |
| SEER29 models scored | 42% | Not ranked | 15.5 |
| EER29 models scored | 77% | Not ranked | 13.0 |
| Heating capacity at 5°F9 models scored | 27% | Not ranked | 16,800 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 33.3% | 3 |
| CEE 2026 Tier 1 (Split ASHP) | 33.3% | 3 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 11.1% | 1 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- SINCLAIR AIR CONDITIONING (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 51% | 63% | 19% | 51% |
| Ducted, 2 tons | 1 | 54% | 73% | 36% | 34% |
| Ducted, 2.5–3 tons | 3 | 53% | 78% | 48% | 42% |
| Ducted, 3.5–4.5 tons | 3 | 56% | 78% | 53% | 47% |
| Ducted, 5 tons and up | 1 | 60% | 96% | 55% | 28% |
Every SINCLAIR AIR CONDITIONING model in the market
- SINCLAIR AIR CONDITIONING models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 864 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 727 | 1.80 | 1.86 | 2.00 | 2.12 | 2.40 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top SINCLAIR AIR CONDITIONING models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1BH719M36P-**ASINCLAIR AIR CONDITIONING · BH719M Serieswith ducted air handler BC724[C,U]BT-**+TDR | 2 tons23,000 Btu/h · Ducted | 71% | 1.98 | 8.5 | 17,000 | 15.5 | CEE 25CEE 26Xcel | 299 | 217505027 | Ducted, 2.5–3 tons | 42.7 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1BH719M36P-**ASINCLAIR AIR CONDITIONING · BH719M Serieswith indoor coil BC724[C,U]BT-**+TDR and furnace B97UR702V3B | 2 tons23,800 Btu/h · Ducted | 68% | 2.02 | 8.5 | 20.0 | 13.2 | CEE 25CEE 26Xcel | 299 | 217547619 | Ducted, 2.5–3 tons | 68.5 | 45.3 | 91.7 | 42.7 |
| 2BH714S60P-**ASINCLAIR AIR CONDITIONING · BH714S Serieswith ducted air handler BAH7V60PT- | 5 tons57,000 Btu/h · Ducted | 54% | 2.24 | 8.1 | 14.7 | 12.2 | None | 20 | 216372515 | Ducted, 5 tons and up | 66.7 | 70.8 | 62.6 | Not a pick |
| 3BH714S42P-**ASINCLAIR AIR CONDITIONING · BH714S Serieswith indoor coil BC748[C,U]CT-**+TDR and furnace B80UR901E5C | 3.5 tons41,500 Btu/h · Ducted | 52% | 2.12 | 7.8 | 15.5 | 13.0 | None | 94 | 216372365 | Ducted, 3.5–4.5 tons | 60.7 | 48.0 | 73.4 | Not a pick |
| 4BH714S48P-**ASINCLAIR AIR CONDITIONING · BH714S Serieswith indoor coil BC760[C,U]CT-**+TDR and furnace B80UR1102E5C | 4 tons48,000 Btu/h · Ducted | 51% | 2.14 | 8.1 | 15.2 | 12.8 | None | 81 | 216372470 | Ducted, 3.5–4.5 tons | 60.0 | 50.7 | 69.3 | Not a pick |
| 5BH714S30P-**ASINCLAIR AIR CONDITIONING · BH714S Serieswith ducted air handler BAH7E36PT- | 2.5 tons29,600 Btu/h · Ducted | 53% | 2.12 | 8.2 | 15.2 | 13.0 | None | 145 | 216372131 | Ducted, 2.5–3 tons | 58.8 | 51.8 | 65.8 | Not a pick |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | BH714S60P-**A | 2.26 | Ducted, 5 tons and up | 96% | 216372514 |
| Capacity retention at 5°F | BH714S60P-**A | 54% | Ducted, 5 tons and up | 52% | 216372514 |
| HSPF2 | BH714S60P-**A | 8.1 | Ducted, 5 tons and up | 63% | 216372515 |
| SEER2 | BH719M36P-**A | 20.0 | Ducted, 2 tons | 87% | 217505087 |
| EER2 | BH714S30P-**A | 13.4 | Ducted, 2.5–3 tons | 99% | 216372169 |
| Heating capacity at 5°F | BH714S60P-**A | 30,200 Btu/h | Ducted, 5 tons and up | 51% | 216372514 |
SINCLAIR AIR CONDITIONING size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | 52.1(50 is the typical model of its size class)BH714S18P-**Awith indoor coil BC730HAT-**+TDR and furnace B80UR702E3A1 of 1 models have all five ratings · AHRI 216371993 |
| Ducted, 2 tons | 42.7(50 is the typical model of its size class)BH719M36P-**Awith ducted air handler BC724[C,U]BT-**+TDR1 of 2 models qualify · AHRI 217505027 | 68.5(50 is the typical model of its size class)BH719M36P-**Awith indoor coil BC724[C,U]BT-**+TDR and furnace B97UR702V3B2 of 2 models have all five ratings · AHRI 217547619 |
| Ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 58.8(50 is the typical model of its size class)BH714S30P-**Awith ducted air handler BAH7E36PT-2 of 2 models have all five ratings · AHRI 216372131 |
| Ducted, 3.5–4.5 tons | None on this board (0 of 3 models qualify) | 60.7(50 is the typical model of its size class)BH714S42P-**Awith indoor coil BC748[C,U]CT-**+TDR and furnace B80UR901E5C3 of 3 models have all five ratings · AHRI 216372365 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | 66.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-1 of 1 models have all five ratings · AHRI 216372515 |
Newest SINCLAIR AIR CONDITIONING certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| BH719M36P-**ASINCLAIR AIR CONDITIONING · BH719M SERIESwith ducted air handler BAH7ER24DT- | 2 tons23,800 Btu/h · Ducted | 1.70 | 57% | 7.5 | 19.5 | CEE 25CEE 26Xcel | 299 | 218598200 |
| BH714S36P-**ASINCLAIR AIR CONDITIONING · BH714S SERIESwith ducted air handler BAH7ER42DT- | 3 tons36,000 Btu/h · Ducted | 1.96 | 53% | 7.8 | 15.2 | None | 130 | 218499742 |
| BH714S30P-**ASINCLAIR AIR CONDITIONING · BH714S SERIESwith indoor coil BC736[C,U]CT-**+TDR and furnace B80UR901E5C | 2.5 tons30,000 Btu/h · Ducted | 1.98 | 51% | 7.5 | 15.5 | None | 145 | 218458734 |
| BH714S42P-**ASINCLAIR AIR CONDITIONING · BH714S SERIESwith ducted air handler BAH7ER42DT- | 3.5 tons40,500 Btu/h · Ducted | 2.02 | 52% | 7.5 | 14.3 | None | 94 | 218426556 |
| BH719M60P-**ASINCLAIR AIR CONDITIONING · BH719M SERIESwith ducted air handler BAH7ER48DT- | 4 tons48,000 Btu/h · Ducted | 1.87 | 62% | 7.8 | 17.0 | CEE 25CEE 26 | 148 | 218426490 |
Compare SINCLAIR AIR CONDITIONING
SINCLAIR AIR CONDITIONING includes these brand names as listed in AHRI: SINCLAIR AIR CONDITIONING. Standards are checked against published thresholds; program rules beyond ratings are not checked.