- Insights
- Manufacturers
- Voltas
Both views use the same certified data. This device remembers your choice.
Voltas heat pump efficiency: 12 outdoor models compared
Voltas has 12 heat pump outdoor models certified with this refrigerant group, in 32 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Voltas makes. Voltas has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 12
- AHRI certifications
- 32
- Efficiency index
- 59%
- Typical model vs same-size, same-type peers (16 models)
- Meet CEE 2025
- 100%
- 12 models
How Voltas compares with comparable models
- Voltas
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index16 models scored | 59% | Not ranked | — |
| COP at 5°F16 models scored | 54% | Not ranked | 2.06 |
| Capacity retention at 5°F16 models scored | 62% | Not ranked | 75% |
| HSPF216 models scored | 51% | Not ranked | 9.0 |
| SEER216 models scored | 62% | Not ranked | 20.0 |
| EER216 models scored | 64% | Not ranked | 12.0 |
| Heating capacity at 5°F16 models scored | 59% | Not ranked | 22,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 12 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 12 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 83.3% | 10 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 66.7% | 8 |
Sizes and duct types offered
- Voltas (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 66% | 58% | 61% | 60% |
| Ducted, 2 tons | 1 | 47% | 93% | 39% | 36% |
| Ducted, 2.5 to 3 tons | 3 | 66% | 43% | 60% | 67% |
| Ducted, 3.5 to 4.5 tons | 2 | 71% | 58% | 70% | 82% |
| Ducted, 5 tons and up | 1 | 81% | 99% | 74% | 97% |
| Non-ducted, up to 1.5 tons | 4 | 52% | 75% | 42% | 48% |
| Non-ducted, 2 tons | 1 | 36% | 37% | 26% | 33% |
| Non-ducted, 2.5 to 3 tons | 2 | 64% | 12% | 60% | 68% |
| Non-ducted, 3.5 to 4.5 tons | 1 | 44% | 7% | 14% | 72% |
Every Voltas model in the market
- Voltas models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Voltas models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1VAUWR-60HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-60HCDR2 | 5 tons57,000 Btu/h · Ducted | 75% | 2.42 | 9.0 | 42,500 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 217269209 | Ducted, 5 tons and up | 88.6 |
| 2VAUWR-36HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-36HCDR2 | 2.5 tons32,000 Btu/h · Ducted | 97% | 2.15 | 10.5 | 31,000 | 19.5 | CEE 25CEE 26XcelES CC | 3 | 217269207 | Ducted, 2.5 to 3 tons | 88.1 |
| 3VAUWR-24HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-24HCDR2 | 2 tons24,000 Btu/h · Ducted | 88% | 2.30 | 10.0 | 21,000 | 20.0 | CEE 25CEE 26XcelES CC | 3 | 217269206 | Ducted, 2 tons | 82.1 |
| 4VAUWR-48HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-48HCDR2 | 4 tons48,000 Btu/h · Ducted | 77% | 2.52 | 9.0 | 37,000 | 19.0 | CEE 25CEE 26XcelES CC | 3 | 217269208 | Ducted, 3.5 to 4.5 tons | 77.3 |
| 5VMTCUHC18VTS25Voltas · MultiMax Vertis Series | 1.5 tons18,000 Btu/h · Non-ducted | 100% | 1.99 | 10.0 | 18,000 | 22.0 | CEE 25CEE 26XcelES CC | 3 | 218160595 | Non-ducted, up to 1.5 tons | 71.0 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1VAUWR-36HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-36HCDR2 | 2.5 tons32,000 Btu/h · Ducted | 97% | 2.15 | 10.5 | 19.5 | 11.7 | CEE 25CEE 26XcelES CC | 3 | 217269207 | Ducted, 2.5 to 3 tons | 83.0 | 88.1 | 77.8 | 88.1 |
| 2VAUWR-48HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-48HCDR2 | 4 tons48,000 Btu/h · Ducted | 77% | 2.52 | 9.0 | 19.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217269208 | Ducted, 3.5 to 4.5 tons | 82.6 | 77.3 | 87.8 | 77.3 |
| 3VAUWR-60HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-60HCDR2 | 5 tons57,000 Btu/h · Ducted | 75% | 2.42 | 9.0 | 19.0 | 11.0 | CEE 25CEE 26XcelES CC | 3 | 217269209 | Ducted, 5 tons and up | 81.1 | 88.6 | 73.6 | 88.6 |
| 4VAUWR-24HCDR2Voltas · Whole House Heat Pump Vertis Serieswith ducted air handler VAUH-24HCDR2 | 2 tons24,000 Btu/h · Ducted | 88% | 2.30 | 10.0 | 20.0 | 12.0 | CEE 25CEE 26XcelES CC | 3 | 217269206 | Ducted, 2 tons | 79.8 | 82.1 | 77.5 | 82.1 |
| 5VMTCUHC36VTS25Voltas · MultiMax Vertis Series | 3 tons36,000 Btu/h · Ducted | 90% | 1.80 | 9.0 | 19.0 | 12.9 | CEE 25CEE 26XcelES CC | 3 | 218160604 | Ducted, 2.5 to 3 tons | 72.2 | 54.0 | 90.5 | 54.0 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | CU-VST18HC-WIFIDR25 | 2.53 | Non-ducted, up to 1.5 tons | 100% | 218324262 |
| Capacity retention at 5°F | VAUWR-60HCDR2 | 75% | Ducted, 5 tons and up | 95% | 217269209 |
| HSPF2 | VAUWR-36HCDR2 | 10.5 | Ducted, 2.5 to 3 tons | 96% | 217269207 |
| SEER2 | VAUWR-60HCDR2 | 19.0 | Ducted, 5 tons and up | 95% | 217269209 |
| EER2 | VMTCUHC36VTS25 | 12.9 | Ducted, 2.5 to 3 tons | 95% | 218160604 |
| Heating capacity at 5°F | VMTCUHC18VTS25 | 18,000 Btu/h | Non-ducted, up to 1.5 tons | 94% | 218160595 |
Voltas size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 67.4(50 is the typical model of its size class)VMTCUHC18VTS251 of 1 models qualify · AHRI 218160596 | 66.1(50 is the typical model of its size class)VMTCUHC18VTS251 of 1 models have all five ratings · AHRI 218160596 |
| Ducted, 2 tons | 82.1(50 is the typical model of its size class)VAUWR-24HCDR2with ducted air handler VAUH-24HCDR21 of 1 models qualify · AHRI 217269206 | 79.8(50 is the typical model of its size class)VAUWR-24HCDR2with ducted air handler VAUH-24HCDR21 of 1 models have all five ratings · AHRI 217269206 |
| Ducted, 2.5 to 3 tons | 88.1(50 is the typical model of its size class)VAUWR-36HCDR2with ducted air handler VAUH-36HCDR23 of 3 models qualify · AHRI 217269207 | 83.0(50 is the typical model of its size class)VAUWR-36HCDR2with ducted air handler VAUH-36HCDR23 of 3 models have all five ratings · AHRI 217269207 |
| Ducted, 3.5 to 4.5 tons | 77.3(50 is the typical model of its size class)VAUWR-48HCDR2with ducted air handler VAUH-48HCDR22 of 2 models qualify · AHRI 217269208 | 82.6(50 is the typical model of its size class)VAUWR-48HCDR2with ducted air handler VAUH-48HCDR22 of 2 models have all five ratings · AHRI 217269208 |
| Ducted, 5 tons and up | 88.6(50 is the typical model of its size class)VAUWR-60HCDR2with ducted air handler VAUH-60HCDR21 of 1 models qualify · AHRI 217269209 | 81.1(50 is the typical model of its size class)VAUWR-60HCDR2with ducted air handler VAUH-60HCDR21 of 1 models have all five ratings · AHRI 217269209 |
| Non-ducted, up to 1.5 tons | 71.0(50 is the typical model of its size class)VMTCUHC18VTS252 of 4 models qualify · AHRI 218160595 | 71.0(50 is the typical model of its size class)VMTCUHC18VTS254 of 4 models have all five ratings · AHRI 218160595 |
| Non-ducted, 2 tons | 40.4(50 is the typical model of its size class)CU-VST24HC-WIFIDR25with ductless indoor unit EU- VST24HC-WIFIDR251 of 1 models qualify · AHRI 218457908 | 36.2(50 is the typical model of its size class)CU-VST24HC-WIFIDR25with ductless indoor unit EU- VST24HC-WIFIDR251 of 1 models have all five ratings · AHRI 218457908 |
| Non-ducted, 2.5 to 3 tons | 54.5(50 is the typical model of its size class)VMTCUHC36VTS252 of 2 models qualify · AHRI 218160605 | 64.9(50 is the typical model of its size class)VMTCUHC27VTS252 of 2 models have all five ratings · AHRI 218160598 |
| Non-ducted, 3.5 to 4.5 tons | 16.8(50 is the typical model of its size class)VMTCUHC42VTS251 of 1 models qualify · AHRI 218160602 | 43.6(50 is the typical model of its size class)VMTCUHC42VTS251 of 1 models have all five ratings · AHRI 218160602 |
Newest Voltas certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| VAUWR-60HCDR2Voltaswith ducted air handler D(A,C,E)61C4J+TDR | 4.5 tons54,000 Btu/h · Ducted | 2.32 | 62% | 8.2 | 16.0 | CEE 25CEE 26XcelES CC | 3 | 218461486 |
| VAUWR-48HCDR2Voltaswith ducted air handler D(A,C,E)49B3J+TDR | 4 tons45,000 Btu/h · Ducted | 2.46 | 70% | 8.2 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 218461485 |
| VAUWR-36HCDR2Voltaswith ducted air handler D(A,C,E)37D3J+TDR | 2.5 tons32,000 Btu/h · Ducted | 2.35 | 73% | 8.2 | 16.5 | CEE 25CEE 26XcelES CC | 3 | 218461484 |
| VAUWR-24HCDR2Voltaswith ducted air handler D(A,C,E)31D2J+TDR | 2 tons22,400 Btu/h · Ducted | 2.57 | 71% | 8.2 | 16.0 | CEE 25CEE 26XcelES CC | 3 | 218461483 |
| CU-VST24HC-WIFIDR25Voltaswith ductless indoor unit EU- VST24HC-WIFIDR25 | 2 tons24,000 Btu/h · Non-ducted | 1.98 | 76% | 9.0 | 19.5 | CEE 25CEE 26Xcel | 2 | 218457908 |
Compare Voltas
Voltas includes these brand names as listed in AHRI: Voltas. Standards are checked against published thresholds; program rules beyond ratings are not checked.