Both views use the same certified data. This device remembers your choice.
XLINE heat pump efficiency: 8 outdoor models compared
XLINE has 8 heat pump outdoor models certified with this refrigerant group, in 9 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes XLINE makes. XLINE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
Simple view, for homeowners: top picks by size and what each rating measures →
ManufacturerData as of updated · sources
- Outdoor models
- 8
- AHRI certifications
- 9
- Efficiency index
- 56%
- Typical model vs same-size, same-type peers (9 models)
- Meet CEE 2025
- 100%
- 8 models
How XLINE compares with comparable models
- XLINE
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index9 models scored | 56% | Not ranked | — |
| COP at 5°F9 models scored | 65% | Not ranked | 2.05 |
| Capacity retention at 5°F9 models scored | 47% | Not ranked | 76% |
| HSPF29 models scored | 78% | Not ranked | 9.8 |
| SEER29 models scored | 59% | Not ranked | 18.4 |
| EER29 models scored | 40% | Not ranked | 10.5 |
| Heating capacity at 5°F9 models scored | 67% | Not ranked | 23,600 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 8 |
| CEE 2026 Tier 1 (Split ASHP) | 75% | 6 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 75% | 6 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 0% | 0 |
Sizes and duct types offered
- XLINE (median, middle 50%, 10th to 90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 1 | 73% | 82% | 87% | 83% |
| Ducted, 2 tons | 2 | 65% | 59% | 86% | 68% |
| Ducted, 2.5 to 3 tons | 2 | 51% | 67% | 76% | 62% |
| Ducted, 3.5 to 4.5 tons | 2 | 52% | 43% | 73% | 61% |
| Non-ducted, up to 1.5 tons | 2 | 50% | 83% | 73% | 34% |
Every XLINE model in the market
- XLINE models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 897 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 463 | 1.80 | 1.86 | 2.00 | 2.41 | 2.44 |
| Ducted, 1.5 tons | 1,035 | 1.75 | 1.82 | 2.00 | 2.20 | 2.40 |
| Ducted, 2 tons | 1,073 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,136 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 736 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 898 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 769 | 1.80 | 1.85 | 2.00 | 2.12 | 2.39 |
| Ducted, 4.5 tons | 724 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 91 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,382 | 1.75 | 1.80 | 1.90 | 2.00 | 2.21 |
| Non-ducted, 1 ton | 1,620 | 1.80 | 1.80 | 1.95 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,483 | 1.80 | 1.80 | 2.00 | 2.10 | 2.28 |
| Non-ducted, 2 tons | 861 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 454 | 1.80 | 1.88 | 2.00 | 2.00 | 2.21 |
| Non-ducted, 3 tons | 522 | 1.80 | 1.97 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 304 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 214 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 80 | 1.90 | 1.91 | 1.96 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 88 | 1.99 | 2.04 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top XLINE models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1XL422XLINEwith ducted air handler XL595 | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19,000 | 19.0 | CEE 25CEE 26Xcel | 1 | 218009419 | Ducted, 2 tons | 77.1 |
| 2XL362XLINEwith ductless indoor unit XL436 | 1.5 tons16,800 Btu/h · Non-ducted | 71% | 2.19 | 11.4 | 12,800 | 20.7 | CEE 25CEE 26Xcel | 2 | 218009417 | Non-ducted, up to 1.5 tons | 69.5 |
| 3XL442XLINEwith ducted air handler XL614 | 4 tons48,000 Btu/h · Ducted | 76% | 2.00 | 9.8 | 38,000 | 17.1 | CEE 25CEE 26Xcel | 1 | 218009421 | Ducted, 3.5 to 4.5 tons | 67.8 |
| 4XL362XLINEwith ducted air handler XL537 | 1.5 tons17,000 Btu/h · Ducted | 70% | 2.21 | 10.5 | 14,000 | 20.0 | CEE 25CEE 26Xcel | 2 | 218009418 | Ducted, up to 1.5 tons | 64.6 |
| 5XL721XLINEwith ducted air handler XL850 | 3 tons36,000 Btu/h · Ducted | 75% | 2.00 | 8.7 | 27,000 | 16.1 | CEE 25CEE 26Xcel | 1 | 218009414 | Ducted, 2.5 to 3 tons | 59.8 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1XL422XLINEwith ducted air handler XL595 | 2 tons24,000 Btu/h · Ducted | 76% | 2.30 | 11.0 | 19.0 | 12.5 | CEE 25CEE 26Xcel | 1 | 218009419 | Ducted, 2 tons | 78.9 | 77.1 | 80.7 | 77.1 |
| 2XL362XLINEwith ducted air handler XL537 | 1.5 tons17,000 Btu/h · Ducted | 70% | 2.21 | 10.5 | 20.0 | 12.5 | CEE 25CEE 26Xcel | 2 | 218009418 | Ducted, up to 1.5 tons | 72.9 | 64.6 | 81.2 | 64.6 |
| 3XL362XLINEwith ductless indoor unit XL436 | 1.5 tons16,800 Btu/h · Non-ducted | 71% | 2.19 | 11.4 | 20.7 | 12.5 | CEE 25CEE 26Xcel | 2 | 218009417 | Non-ducted, up to 1.5 tons | 60.9 | 69.5 | 52.2 | 69.5 |
| 4XL464XLINEwith ducted air handler XL615 | 3 tons36,000 Btu/h · Ducted | 64% | 2.10 | 10.2 | 18.7 | 10.1 | CEE 25 | 1 | 218009420 | Ducted, 2.5 to 3 tons | 58.0 | 68.8 | 47.2 | Not a pick |
| 5XL442XLINEwith ducted air handler XL614 | 4 tons48,000 Btu/h · Ducted | 76% | 2.00 | 9.8 | 17.1 | 10.0 | CEE 25CEE 26Xcel | 1 | 218009421 | Ducted, 3.5 to 4.5 tons | 56.8 | 67.8 | 45.8 | 67.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | XL362 | 2.19 | Non-ducted, up to 1.5 tons | 84% | 218009417 |
| Capacity retention at 5°F | XL701 | 83% | Ducted, 2 tons | 63% | 218009413 |
| HSPF2 | XL422 | 11.0 | Ducted, 2 tons | 94% | 218009419 |
| SEER2 | XL362 | 20.0 | Ducted, up to 1.5 tons | 83% | 218009418 |
| EER2 | XL422 | 12.5 | Ducted, 2 tons | 82% | 218009419 |
| Heating capacity at 5°F | XL362 | 14,000 Btu/h | Ducted, up to 1.5 tons | 76% | 218009418 |
XLINE size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 64.6(50 is the typical model of its size class)XL362with ducted air handler XL5371 of 1 models qualify · AHRI 218009418 | 72.9(50 is the typical model of its size class)XL362with ducted air handler XL5371 of 1 models have all five ratings · AHRI 218009418 |
| Ducted, 2 tons | 77.1(50 is the typical model of its size class)XL422with ducted air handler XL5952 of 2 models qualify · AHRI 218009419 | 78.9(50 is the typical model of its size class)XL422with ducted air handler XL5952 of 2 models have all five ratings · AHRI 218009419 |
| Ducted, 2.5 to 3 tons | 59.8(50 is the typical model of its size class)XL721with ducted air handler XL8501 of 2 models qualify · AHRI 218009414 | 58.0(50 is the typical model of its size class)XL464with ducted air handler XL6152 of 2 models have all five ratings · AHRI 218009420 |
| Ducted, 3.5 to 4.5 tons | 67.8(50 is the typical model of its size class)XL442with ducted air handler XL6142 of 2 models qualify · AHRI 218009421 | 56.8(50 is the typical model of its size class)XL442with ducted air handler XL6142 of 2 models have all five ratings · AHRI 218009421 |
| Non-ducted, up to 1.5 tons | 69.5(50 is the typical model of its size class)XL362with ductless indoor unit XL4361 of 2 models qualify · AHRI 218009417 | 60.9(50 is the typical model of its size class)XL362with ductless indoor unit XL4362 of 2 models have all five ratings · AHRI 218009417 |
Newest XLINE certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| XL442XLINEwith ducted air handler XL614 | 4 tons48,000 Btu/h · Ducted | 2.00 | 76% | 9.8 | 17.1 | CEE 25CEE 26Xcel | 1 | 218009421 |
| XL464XLINEwith ducted air handler XL615 | 3 tons36,000 Btu/h · Ducted | 2.10 | 64% | 10.2 | 18.7 | CEE 25 | 1 | 218009420 |
| XL422XLINEwith ducted air handler XL595 | 2 tons24,000 Btu/h · Ducted | 2.30 | 76% | 11.0 | 19.0 | CEE 25CEE 26Xcel | 1 | 218009419 |
| XL362XLINEwith ducted air handler XL537 | 1.5 tons17,000 Btu/h · Ducted and non-ducted | 2.21 | 70% | 10.5 | 20.0 | CEE 25CEE 26Xcel | 2 | 218009418 |
| XL020XLINEwith ductless indoor unit XL381 | 1.5 tons18,000 Btu/h · Non-ducted | 2.15 | 61% | 9.6 | 19.2 | CEE 25 | 1 | 218009416 |
Compare XLINE
XLINE includes these brand names as listed in AHRI: XLINE. Standards are checked against published thresholds; program rules beyond ratings are not checked.