Skip to content

ZONE heat pump efficiency: 4 outdoor models compared

ZONE has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes ZONE makes. ZONE has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
64%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
100%
4 models

How ZONE compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
ZONE against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of ZONE’s own modelsZONE is strongest on SEER2 (its typical model beats 79% of comparable models) and weakest on capacity retention at 5°F (38%).
  • ZONE
  • Middle half of its models
  • Other ranked manufacturers
ZONE

Source: AHRI Directory, NEEP · as of

Average peer percentile of ZONE’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored64%Not ranked—
COP at 5°F4 models scored57%Not ranked2.05
Capacity retention at 5°F4 models scored38%Not ranked72%
HSPF24 models scored71%Not ranked10.0
SEER24 models scored79%Not ranked23.5
EER24 models scored67%Not ranked12.8
Heating capacity at 5°F4 models scored45%Not ranked11,350 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
ZONE’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • ZONE (median, middle 50%, 10th to 90th)
  • All models of the group
Non-ducted, up to 1.5 tons1.944,074 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Non-ducted, up to 1.5 tons363%58%68%75%
Non-ducted, 2.5 to 3 tons166%53%81%91%

Every ZONE model in the market

ZONE’s 4 models with a known size and duct type, over the shape of the whole catalog.
ZONE models by size and ratingColoured: ZONE · grey shapes: all 15,909 models · lines: catalog medians by size
  • ZONE models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 zone models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,909 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8871.641.711.751.852.24
Ducted, 1 ton4591.801.872.002.412.44
Ducted, 1.5 tons1,0291.751.832.002.202.40
Ducted, 2 tons1,0711.751.862.002.182.30
Ducted, 2.5 tons1,1341.701.802.002.102.35
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7671.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3831.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4811.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2131.961.972.052.102.11
Non-ducted, 4.5 tons811.901.911.972.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top ZONE models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 4 ZONE cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1ZBND-MK2-12OZONEwith ductless indoor unit ZBND-MK2-12I1 ton12,000 Btu/h · Non-ducted72%2.1010.09,10024.0CEE 25CEE 26Xcel1218679548Non-ducted, up to 1.5 tons61.2
2ZBND-MK1-12OZONEwith ductless indoor unit ZBND-MK1-12I1 ton12,000 Btu/h · Non-ducted72%2.1010.08,90023.0CEE 25CEE 26Xcel1218679547Non-ducted, up to 1.5 tons60.6
3ZBND-MK1-27OZONE2.5 tons27,000 Btu/h · Non-ducted71%2.0010.519,80024.0CEE 25CEE 26Xcel1218679550Non-ducted, 2.5 to 3 tons58.2
4ZBND-MK2-18OZONEwith ductless indoor unit ZBND-MK2-18I1.5 tons18,000 Btu/h · Non-ducted72%1.8010.013,60023.0CEE 25CEE 26Xcel1218679549Non-ducted, up to 1.5 tons40.9

All-around best

Top 4 ZONE models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1ZBND-MK2-12OZONEwith ductless indoor unit ZBND-MK2-12I1 ton12,000 Btu/h · Non-ducted72%2.1010.024.013.0CEE 25CEE 26Xcel1218679548Non-ducted, up to 1.5 tons69.561.277.861.2
2ZBND-MK1-12OZONEwith ductless indoor unit ZBND-MK1-12I1 ton12,000 Btu/h · Non-ducted72%2.1010.023.013.0CEE 25CEE 26Xcel1218679547Non-ducted, up to 1.5 tons66.960.673.260.6
3ZBND-MK1-27OZONE2.5 tons27,000 Btu/h · Non-ducted71%2.0010.524.012.0CEE 25CEE 26Xcel1218679550Non-ducted, 2.5 to 3 tons65.958.273.658.2
4ZBND-MK2-18OZONEwith ductless indoor unit ZBND-MK2-18I1.5 tons18,000 Btu/h · Non-ducted72%1.8010.023.012.5CEE 25CEE 26Xcel1218679549Non-ducted, up to 1.5 tons53.640.966.440.9

Best model on each rating

ZONE’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FZBND-MK1-12O2.10Non-ducted, up to 1.5 tons78%218679547
Capacity retention at 5°FZBND-MK2-12O72%Non-ducted, up to 1.5 tons38%218679548
HSPF2ZBND-MK1-27O10.5Non-ducted, 2.5 to 3 tons81%218679550
SEER2ZBND-MK1-27O24.0Non-ducted, 2.5 to 3 tons90%218679550
EER2ZBND-MK1-12O13.0Non-ducted, up to 1.5 tons73%218679547
Heating capacity at 5°FZBND-MK2-18O13,600 Btu/hNon-ducted, up to 1.5 tons80%218679549

All 4 ZONE models in Explore

ZONE size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
ZONE: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Non-ducted, up to 1.5 tons61.2(50 is the typical model of its size class)ZBND-MK2-12Owith ductless indoor unit ZBND-MK2-12I3 of 3 models qualify · AHRI 21867954869.5(50 is the typical model of its size class)ZBND-MK2-12Owith ductless indoor unit ZBND-MK2-12I3 of 3 models have all five ratings · AHRI 218679548
Non-ducted, 2.5 to 3 tons58.2(50 is the typical model of its size class)ZBND-MK1-27O1 of 1 models qualify · AHRI 21867955065.9(50 is the typical model of its size class)ZBND-MK1-27O1 of 1 models have all five ratings · AHRI 218679550

All-around board, every manufacturer

Newest ZONE certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified ZONE outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
ZBND-MK1-27OZONE2.5 tons27,000 Btu/h · Non-ducted2.0071%10.524.0CEE 25CEE 26Xcel1218679550
ZBND-MK2-18OZONEwith ductless indoor unit ZBND-MK2-18I1.5 tons18,000 Btu/h · Non-ducted1.8072%10.023.0CEE 25CEE 26Xcel1218679549
ZBND-MK2-12OZONEwith ductless indoor unit ZBND-MK2-12I1 ton12,000 Btu/h · Non-ducted2.1072%10.024.0CEE 25CEE 26Xcel1218679548
ZBND-MK1-12OZONEwith ductless indoor unit ZBND-MK1-12I1 ton12,000 Btu/h · Non-ducted2.1072%10.023.0CEE 25CEE 26Xcel1218679547

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for ZONE in this group.

Compare ZONE

Manufacturers of a similar size, side by side.

ZONE includes these brand names as listed in AHRI: ZONE. Standards are checked against published thresholds; program rules beyond ratings are not checked.

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter