AAON vs Armbridge heat pumps
Measured against models of the same size and duct type, Armbridge scores higher on 5 of the 6 ratings. AAON has 28 outdoor models, Armbridge has 29 outdoor models. AAON and Armbridge have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AAON
- Armbridge
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AAON | Armbridge |
|---|---|---|
| Efficiency index | 37%median — | 52%median — |
| COP at 5°F | 23%median 1.60 | 42%median 1.90 |
| Capacity retention at 5°F | 23%median 41% | 46%median 64% |
| HSPF2 | 34%median 7.4 | 61%median 9.5 |
| SEER2 | 45%median 15.9 | 63%median 18.4 |
| EER2 | 84% (higher)median 12.4 | 46% (higher)median 10.5 |
| Heating capacity at 5°F | 28%median 22,400 Btu/h | 48%median 19,000 Btu/h |
| Outdoor models | 28 | 29 |
| AHRI certifications | 55 | 64 |
Share of models meeting each standard
| Standard | AAON | Armbridge |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 3.6%1 models | 51.7%15 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 51.7%15 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 3.4%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 48.3%14 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 3.4%1 models |
| ENERGY STAR Cold Climate | 0%0 models | 31%9 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AAON
- Armbridge
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AAON | Armbridge |
|---|---|---|
| Ducted, 2 tons | 5 · index 33% | 4 · index 50% |
| Ducted, 2.5 to 3 tons | 7 · index 33% | 7 · index 53% |
| Ducted, 3.5 to 4.5 tons | 14 · index 36% | 6 · index 51% |
| Ducted, 5 tons and up | 2 · index 60% | None |
| Ducted, up to 1.5 tons | None | 4 · index 55% |
| Non-ducted, up to 1.5 tons | None | 7 · index 46% |
| Non-ducted, 2 tons | None | 3 · index 63% |
| Non-ducted, 2.5 to 3 tons | None | 5 · index 45% |
| Non-ducted, 3.5 to 4.5 tons | None | 2 · index 75% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AAONCold-climate score, best model | ArmbridgeCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 69.4(50 is the typical model of its size class)AB-GTMH18-230VO3 of 4 models qualify · AHRI 218059661 |
| Ducted, 2 tons | None on this board (0 of 5 models qualify) | 59.1(50 is the typical model of its size class)AB-GTMR24-230VO3 of 4 models qualify · AHRI 218059657 |
| Ducted, 2.5 to 3 tons | 44.8(50 is the typical model of its size class)RQ-003-3-0-KBBS-V0-21-000-A1 of 7 models qualify · AHRI 218026592 | 73.7(50 is the typical model of its size class) (higher)AB-GTMR30-230VO3 of 7 models qualify · AHRI 218059658 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 14 models qualify) | 77.1(50 is the typical model of its size class)AB-GTMR42-230VOAlso listed as AB-GTMH42-230VO2 of 6 models qualify · AHRI 218059660 |
| Ducted, 5 tons and up | None on this board (0 of 2 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 81.6(50 is the typical model of its size class)AB-GTMH18-230VO5 of 7 models qualify · AHRI 218059652 |
| Non-ducted, 2 tons | No models in this size class | 83.7(50 is the typical model of its size class)AB-GTMH24-230VO3 of 3 models qualify · AHRI 218059653 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 73.6(50 is the typical model of its size class)AB-GTMH36-230VO3 of 5 models qualify · AHRI 218059654 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 60.3(50 is the typical model of its size class)AB-GTMR42-230VOAlso listed as AB-GTMH42-230VO2 of 2 models qualify · AHRI 218059669 |
All-around best
| Size and duct type | AAONAll-around score, best model | ArmbridgeAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 76.7(50 is the typical model of its size class)AB-GTMH18-230VO4 of 4 models have all five ratings · AHRI 218059661 |
| Ducted, 2 tons | 33.4(50 is the typical model of its size class)RQ-002-3-0-HBAC-V0-21-000-A1 of 5 models have all five ratings · AHRI 214610309 | 76.3(50 is the typical model of its size class) (higher)AB-GTMH24-230VO4 of 4 models have all five ratings · AHRI 218059662 |
| Ducted, 2.5 to 3 tons | 36.9(50 is the typical model of its size class)RQ-003-3-0-KBBS-V0-21-000-A3 of 7 models have all five ratings · AHRI 218026592 | 81.4(50 is the typical model of its size class) (higher)AB-GTMH36-230VO7 of 7 models have all five ratings · AHRI 218059663 |
| Ducted, 3.5 to 4.5 tons | 44.7(50 is the typical model of its size class)RQ-004-3-0-HBAC-V0-21-000-A4 of 14 models have all five ratings · AHRI 214610315 | 87.2(50 is the typical model of its size class) (higher)AB-GTMR42-230VOAlso listed as AB-GTMH42-230VO6 of 6 models have all five ratings · AHRI 218059660 |
| Ducted, 5 tons and up | 60.4(50 is the typical model of its size class)RQ-005-3-0-HBAC-V0-21-000-A1 of 2 models have all five ratings · AHRI 214610319 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 75.0(50 is the typical model of its size class)AB-GTMH18-230VO7 of 7 models have all five ratings · AHRI 218059652 |
| Non-ducted, 2 tons | No models in this size class | 85.6(50 is the typical model of its size class)AB-GTMH24-230VO3 of 3 models have all five ratings · AHRI 218059653 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 78.7(50 is the typical model of its size class)AB-GTMH36-230VO5 of 5 models have all five ratings · AHRI 218059654 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 74.5(50 is the typical model of its size class)AB-GTMR42-230VOAlso listed as AB-GTMH42-230VO2 of 2 models have all five ratings · AHRI 218059669 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AAON | Armbridge |
|---|---|---|
| COP at 5°F | beats 82% · 2.18RQ-005-3-0-HBAC-V0-21-000-ADucted, 5 tons and up | beats 82% · 2.05AB-GTMR30-230VONon-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 82% · 98%RQ-003-3-0-KBBS-V0-21-000-ADucted, 2.5 to 3 tons | beats 96% · 100%AB-GTMH24-230VONon-ducted, 2 tons |
| HSPF2 | beats 71% · 8.9CF-005-3-A-GB0C-00-21-000-ADucted, 5 tons and up | beats 96% · 11.0AB-GTMH36-230VONon-ducted, 2.5 to 3 tons |
| SEER2 | beats 91% · 19.6CF-002-3-A-FB0C-00-21-000-ADucted, 2.5 to 3 tons | beats 100% · 22.0AB-GTMR42-230VOAlso listed as AB-GTMH42-230VODucted, 3.5 to 4.5 tons |
| EER2 | beats 100% · 15.7CF-002-3-A-FB0C-00-21-000-ADucted, 2.5 to 3 tons | beats 91% · 12.3AB-GTMR42-230VOAlso listed as AB-GTMH42-230VODucted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 86% · 34,600 Btu/hRQ-003-3-0-KBBS-V0-21-000-ADucted, 2.5 to 3 tons | beats 99% · 21,800 Btu/hAB-GTMH18-230VONon-ducted, up to 1.5 tons |