Skip to content

agtana vs TK'S Mini Splits Heating & Cooling heat pumps

Measured against models of the same size and duct type, TK'S Mini Splits Heating & Cooling scores higher on 3 of the 6 ratings. agtana has 5 outdoor models, TK'S Mini Splits Heating & Cooling has 5 outdoor models. agtana and TK'S Mini Splits Heating & Cooling have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
agtana and TK'S Mini Splits Heating & Cooling on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, TK'S Mini Splits Heating & Cooling scores higher on 3 of the 6 ratings.
  • agtana
  • TK'S Mini Splits Heating & Cooling
  • Other ranked manufacturers
agtanaTK'S Min…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingagtanaTK'S Mini Splits Heating & Cooling
Efficiency index—median —34%median —
COP at 5°F—median —48%median 1.99
Capacity retention at 5°F—median —15%median 67%
HSPF24%median 8.232%median 9.1
SEER213%median 18.142%median 21.3
EER222%median 10.829%median 10.8
Heating capacity at 5°F—median —30%median 8,000 Btu/h
Outdoor models55
AHRI certifications55

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardagtanaTK'S Mini Splits Heating & Cooling
CEE 2025 Tier 1 (Split ASHP)0%0 models60%3 models
CEE 2026 Tier 1 (Split ASHP)0%0 models60%3 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models20%1 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • agtana
  • TK'S Mini Splits Heating & Cooling
  • All models of the group
Non-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeagtanaTK'S Mini Splits Heating & Cooling
Non-ducted, up to 1.5 tons3 · index —4 · index 35%
Non-ducted, 2 tons1 · index —None
Non-ducted, 2.5–3 tons1 · index —1 · index 27%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeagtanaCold-climate score, best modelTK'S Mini Splits Heating & CoolingCold-climate score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)39.4(50 is the typical model of its size class)TWM-09ODUwith ductless indoor unit TWM-09IDUM1 of 4 models qualify · AHRI 217590532
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeagtanaAll-around score, best modelTK'S Mini Splits Heating & CoolingAll-around score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models have all five ratings)49.2(50 is the typical model of its size class)TWM-09ODUwith ductless indoor unit TWM-09IDUM4 of 4 models have all five ratings · AHRI 217590532
Non-ducted, 2 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models have all five ratings)26.6(50 is the typical model of its size class)TWS-36ODUwith ductless indoor unit TWS-36IDU1 of 1 models have all five ratings · AHRI 217590533

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingagtanaTK'S Mini Splits Heating & Cooling
COP at 5°F—beats 76% · 2.02TWS-36ODUNon-ducted, 2.5–3 tons
Capacity retention at 5°F—beats 24% · 70%TWM-09ODUNon-ducted, up to 1.5 tons
HSPF2beats 4% · 8.2AGAC-12AW1Non-ducted, up to 1.5 tonsbeats 38% · 9.4TWM-09ODUNon-ducted, up to 1.5 tons
SEER2beats 15% · 18.1AGAC-12AW1Non-ducted, up to 1.5 tonsbeats 52% · 21.6TWM-09ODUNon-ducted, up to 1.5 tons
EER2beats 35% · 11.6AGAC-18AW1Non-ducted, up to 1.5 tonsbeats 62% · 12.6TWM-09ODUNon-ducted, up to 1.5 tons
Heating capacity at 5°F—beats 63% · 11,500 Btu/hTWS-18ODUNon-ducted, up to 1.5 tons

More comparisons