Skip to content

AIR C vs NUVELLA heat pumps

Measured against models of the same size and duct type, AIR C scores higher on 6 of the 6 ratings. AIR C has 11 outdoor models, NUVELLA has 11 outdoor models. AIR C and NUVELLA have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIR C and NUVELLA on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AIR C scores higher on 6 of the 6 ratings.
  • AIR C
  • NUVELLA
  • Other ranked manufacturers
AIR CNUVELLA

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIR CNUVELLA
Efficiency index79% (higher)median —44% (higher)median —
COP at 5°F60% (higher)median 2.0044% (higher)median 2.00
Capacity retention at 5°F86% (higher)median 100%41% (higher)median 73%
HSPF288% (higher)median 10.954% (higher)median 9.5
SEER282% (higher)median 23.048% (higher)median 20.0
EER280% (higher)median 13.037% (higher)median 11.2
Heating capacity at 5°F84% (higher)median 22,600 Btu/h35% (higher)median 16,000 Btu/h
Outdoor models1111
AHRI certifications2111

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIR CNUVELLA
CEE 2025 Tier 1 (Split ASHP)90.9%10 models90.9%10 models
CEE 2026 Tier 1 (Split ASHP)90.9%10 models90.9%10 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)100%11 models81.8%9 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • AIR C
  • NUVELLA
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIR CNUVELLA
Ducted, up to 1.5 tons1 · index 78%None
Ducted, 2.5 to 3 tons2 · index 81%None
Ducted, 3.5 to 4.5 tons2 · index 83%None
Non-ducted, up to 1.5 tons6 · index 81%6 · index 44%
Non-ducted, 2 tons1 · index 79%1 · index 43%
Non-ducted, 2.5 to 3 tons2 · index 77%3 · index 47%
Non-ducted, 3.5 to 4.5 tons2 · index 68%1 · index 42%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIR CCold-climate score, best modelNUVELLACold-climate score, best model
Ducted, up to 1.5 tons71.3(50 is the typical model of its size class)UE-H18M1P1 of 1 models qualify · AHRI 215461325No models in this size class
Ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class)UE-H36M1P2 of 2 models qualify · AHRI 215461336No models in this size class
Ducted, 3.5 to 4.5 tons82.6(50 is the typical model of its size class)UE-H48M1P2 of 2 models qualify · AHRI 215461341No models in this size class
Non-ducted, up to 1.5 tons86.5(50 is the typical model of its size class) (higher)UE-SH09S1Pwith ductless indoor unit UI-SH09MS1P5 of 6 models qualify · AHRI 21546131270.1(50 is the typical model of its size class)MYTM20NA23BCH18-O6 of 6 models qualify · AHRI 218079144
Non-ducted, 2 tons90.3(50 is the typical model of its size class)UE-H24S1Pwith ductless indoor unit UI-H24MS1P1 of 1 models qualify · AHRI 215461321None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons78.3(50 is the typical model of its size class) (higher)UE-H36M1P2 of 2 models qualify · AHRI 21546133858.2(50 is the typical model of its size class)MYTM28NA23BCH18-O2 of 3 models qualify · AHRI 218079145
Non-ducted, 3.5 to 4.5 tons73.7(50 is the typical model of its size class) (higher)UE-H48M1P2 of 2 models qualify · AHRI 21546134331.5(50 is the typical model of its size class)MYTM45NA23BCH18-O1 of 1 models qualify · AHRI 218079147

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIR CAll-around score, best modelNUVELLAAll-around score, best model
Ducted, up to 1.5 tons77.9(50 is the typical model of its size class)UE-H18M1P1 of 1 models have all five ratings · AHRI 215461325No models in this size class
Ducted, 2.5 to 3 tons84.3(50 is the typical model of its size class)UE-H36M1P2 of 2 models have all five ratings · AHRI 215461336No models in this size class
Ducted, 3.5 to 4.5 tons84.3(50 is the typical model of its size class)UE-H48M1P2 of 2 models have all five ratings · AHRI 215461341No models in this size class
Non-ducted, up to 1.5 tons92.7(50 is the typical model of its size class) (higher)UE-SH09S1Pwith ductless indoor unit UI-SH09MS1P5 of 6 models have all five ratings · AHRI 21546131273.9(50 is the typical model of its size class)MYTM20NA23BCH18-O6 of 6 models have all five ratings · AHRI 218079144
Non-ducted, 2 tons78.7(50 is the typical model of its size class) (higher)UE-H24S1Pwith ductless indoor unit UI-H24MS1P1 of 1 models have all five ratings · AHRI 21546132143.1(50 is the typical model of its size class)MYTW24NA23BCH20-Owith ductless indoor unit MYTW24NA23BCH20-I1 of 1 models have all five ratings · AHRI 218078441
Non-ducted, 2.5 to 3 tons78.8(50 is the typical model of its size class) (higher)UE-H36M1P2 of 2 models have all five ratings · AHRI 21546133465.9(50 is the typical model of its size class)MYTM28NA23BCH18-O3 of 3 models have all five ratings · AHRI 218079145
Non-ducted, 3.5 to 4.5 tons76.1(50 is the typical model of its size class) (higher)UE-H48M1P2 of 2 models have all five ratings · AHRI 21546133942.3(50 is the typical model of its size class)MYTM45NA23BCH18-O1 of 1 models have all five ratings · AHRI 218079147

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIR CNUVELLA
COP at 5°Fbeats 95% · 2.34UE-H24S1PNon-ducted, 2 tonsbeats 80% · 2.03MYTW36NA23BCH20-ONon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 97% · 113%UE-SH18S1PNon-ducted, up to 1.5 tonsbeats 63% · 80%MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons
HSPF2beats 99% · 11.0UE-H48M1PDucted, 3.5 to 4.5 tonsbeats 81% · 10.5MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons
SEER2beats 99% · 33.3UE-SH09S1PNon-ducted, up to 1.5 tonsbeats 90% · 24.0MYTM28NA23BCH18-ONon-ducted, 2.5 to 3 tons
EER2beats 98% · 17.0UE-SH09S1PNon-ducted, up to 1.5 tonsbeats 73% · 13.0MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 22,600 Btu/hUE-SH18S1PNon-ducted, up to 1.5 tonsbeats 89% · 16,000 Btu/hMYTM20NA23BCH18-ONon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter