Both views use the same certified data. This device remembers your choice.
AIR C vs NUVELLA heat pumps
Measured against models of the same size and duct type, AIR C scores higher on 6 of the 6 ratings. AIR C has 11 outdoor models, NUVELLA has 11 outdoor models. AIR C and NUVELLA have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIR C
- NUVELLA
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIR C | NUVELLA |
|---|---|---|
| Efficiency index | 79% (higher)median — | 44% (higher)median — |
| COP at 5°F | 60% (higher)median 2.00 | 44% (higher)median 2.00 |
| Capacity retention at 5°F | 86% (higher)median 100% | 41% (higher)median 73% |
| HSPF2 | 88% (higher)median 10.9 | 54% (higher)median 9.5 |
| SEER2 | 82% (higher)median 23.0 | 48% (higher)median 20.0 |
| EER2 | 80% (higher)median 13.0 | 37% (higher)median 11.2 |
| Heating capacity at 5°F | 84% (higher)median 22,600 Btu/h | 35% (higher)median 16,000 Btu/h |
| Outdoor models | 11 | 11 |
| AHRI certifications | 21 | 11 |
Share of models meeting each standard
| Standard | AIR C | NUVELLA |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 90.9%10 models | 90.9%10 models |
| CEE 2026 Tier 1 (Split ASHP) | 90.9%10 models | 90.9%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%11 models | 81.8%9 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIR C
- NUVELLA
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIR C | NUVELLA |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index 78% | None |
| Ducted, 2.5 to 3 tons | 2 · index 81% | None |
| Ducted, 3.5 to 4.5 tons | 2 · index 83% | None |
| Non-ducted, up to 1.5 tons | 6 · index 81% | 6 · index 44% |
| Non-ducted, 2 tons | 1 · index 79% | 1 · index 43% |
| Non-ducted, 2.5 to 3 tons | 2 · index 77% | 3 · index 47% |
| Non-ducted, 3.5 to 4.5 tons | 2 · index 68% | 1 · index 42% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIR CCold-climate score, best model | NUVELLACold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 71.3(50 is the typical model of its size class)UE-H18M1P1 of 1 models qualify · AHRI 215461325 | No models in this size class |
| Ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class)UE-H36M1P2 of 2 models qualify · AHRI 215461336 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 82.6(50 is the typical model of its size class)UE-H48M1P2 of 2 models qualify · AHRI 215461341 | No models in this size class |
| Non-ducted, up to 1.5 tons | 86.5(50 is the typical model of its size class) (higher)UE-SH09S1Pwith ductless indoor unit UI-SH09MS1P5 of 6 models qualify · AHRI 215461312 | 70.1(50 is the typical model of its size class)MYTM20NA23BCH18-O6 of 6 models qualify · AHRI 218079144 |
| Non-ducted, 2 tons | 90.3(50 is the typical model of its size class)UE-H24S1Pwith ductless indoor unit UI-H24MS1P1 of 1 models qualify · AHRI 215461321 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | 78.3(50 is the typical model of its size class) (higher)UE-H36M1P2 of 2 models qualify · AHRI 215461338 | 58.2(50 is the typical model of its size class)MYTM28NA23BCH18-O2 of 3 models qualify · AHRI 218079145 |
| Non-ducted, 3.5 to 4.5 tons | 73.7(50 is the typical model of its size class) (higher)UE-H48M1P2 of 2 models qualify · AHRI 215461343 | 31.5(50 is the typical model of its size class)MYTM45NA23BCH18-O1 of 1 models qualify · AHRI 218079147 |
All-around best
| Size and duct type | AIR CAll-around score, best model | NUVELLAAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 77.9(50 is the typical model of its size class)UE-H18M1P1 of 1 models have all five ratings · AHRI 215461325 | No models in this size class |
| Ducted, 2.5 to 3 tons | 84.3(50 is the typical model of its size class)UE-H36M1P2 of 2 models have all five ratings · AHRI 215461336 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 84.3(50 is the typical model of its size class)UE-H48M1P2 of 2 models have all five ratings · AHRI 215461341 | No models in this size class |
| Non-ducted, up to 1.5 tons | 92.7(50 is the typical model of its size class) (higher)UE-SH09S1Pwith ductless indoor unit UI-SH09MS1P5 of 6 models have all five ratings · AHRI 215461312 | 73.9(50 is the typical model of its size class)MYTM20NA23BCH18-O6 of 6 models have all five ratings · AHRI 218079144 |
| Non-ducted, 2 tons | 78.7(50 is the typical model of its size class) (higher)UE-H24S1Pwith ductless indoor unit UI-H24MS1P1 of 1 models have all five ratings · AHRI 215461321 | 43.1(50 is the typical model of its size class)MYTW24NA23BCH20-Owith ductless indoor unit MYTW24NA23BCH20-I1 of 1 models have all five ratings · AHRI 218078441 |
| Non-ducted, 2.5 to 3 tons | 78.8(50 is the typical model of its size class) (higher)UE-H36M1P2 of 2 models have all five ratings · AHRI 215461334 | 65.9(50 is the typical model of its size class)MYTM28NA23BCH18-O3 of 3 models have all five ratings · AHRI 218079145 |
| Non-ducted, 3.5 to 4.5 tons | 76.1(50 is the typical model of its size class) (higher)UE-H48M1P2 of 2 models have all five ratings · AHRI 215461339 | 42.3(50 is the typical model of its size class)MYTM45NA23BCH18-O1 of 1 models have all five ratings · AHRI 218079147 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIR C | NUVELLA |
|---|---|---|
| COP at 5°F | beats 95% · 2.34UE-H24S1PNon-ducted, 2 tons | beats 80% · 2.03MYTW36NA23BCH20-ONon-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 97% · 113%UE-SH18S1PNon-ducted, up to 1.5 tons | beats 63% · 80%MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 99% · 11.0UE-H48M1PDucted, 3.5 to 4.5 tons | beats 81% · 10.5MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons |
| SEER2 | beats 99% · 33.3UE-SH09S1PNon-ducted, up to 1.5 tons | beats 90% · 24.0MYTM28NA23BCH18-ONon-ducted, 2.5 to 3 tons |
| EER2 | beats 98% · 17.0UE-SH09S1PNon-ducted, up to 1.5 tons | beats 73% · 13.0MYTM20NA23BCH18-ONon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 22,600 Btu/hUE-SH18S1PNon-ducted, up to 1.5 tons | beats 89% · 16,000 Btu/hMYTM20NA23BCH18-ONon-ducted, up to 1.5 tons |