AIRSTAR vs CAAIR heat pumps
Measured against models of the same size and duct type, AIRSTAR scores higher on 4 of the 6 ratings. AIRSTAR has 3 outdoor models, CAAIR has 3 outdoor models. AIRSTAR and CAAIR have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIRSTAR
- CAAIR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIRSTAR | CAAIR |
|---|---|---|
| Efficiency index | 60%median — | —median — |
| COP at 5°F | 34%median 1.80 | 66%median 2.08 |
| Capacity retention at 5°F | 53%median 75% | —median — |
| HSPF2 | 58% (higher)median 9.5 | 17% (higher)median 8.5 |
| SEER2 | 73% (higher)median 23.0 | 20% (higher)median 19.0 |
| EER2 | 73% (higher)median 13.0 | 18% (higher)median 10.5 |
| Heating capacity at 5°F | 59% (higher)median 9,000 Btu/h | 0% (higher)median 3,600 Btu/h |
| Outdoor models | 3 | 3 |
| AHRI certifications | 3 | 3 |
Share of models meeting each standard
| Standard | AIRSTAR | CAAIR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%3 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%3 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%3 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIRSTAR
- CAAIR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIRSTAR | CAAIR |
|---|---|---|
| Non-ducted, up to 1.5 tons | 3 · index 60% | 3 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIRSTARCold-climate score, best model | CAAIRCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 68.6(50 is the typical model of its size class)TCL18C25M3 of 3 models qualify · AHRI 217727836 | None on this board (0 of 3 models qualify) |
All-around best
| Size and duct type | AIRSTARAll-around score, best model | CAAIRAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 72.2(50 is the typical model of its size class)TCL18C25M3 of 3 models have all five ratings · AHRI 217727836 | None on this board (0 of 3 models have all five ratings) |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIRSTAR | CAAIR |
|---|---|---|
| COP at 5°F | beats 63% · 2.00TCL18C25MNon-ducted, up to 1.5 tons | beats 85% · 2.20ASW-2-JL18KNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 61% · 80%TCL18C25MNon-ducted, up to 1.5 tons | — |
| HSPF2 | beats 79% · 10.5TCL18C25MNon-ducted, up to 1.5 tons | beats 29% · 9.0ASW-2-JL18KNon-ducted, up to 1.5 tons |
| SEER2 | beats 75% · 24.0TCL18C25MNon-ducted, up to 1.5 tons | beats 30% · 20.0ASW-3-JL12KNon-ducted, up to 1.5 tons |
| EER2 | beats 70% · 13.0TCL18C25MNon-ducted, up to 1.5 tons | beats 28% · 11.0ASW-3-JL12KNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 88% · 16,000 Btu/hTCL18C25MNon-ducted, up to 1.5 tons | beats 0% · 3,600 Btu/hASW-2-JL18KNon-ducted, up to 1.5 tons |