ATOMI vs DEPLUSE heat pumps

Measured against models of the same size and duct type, ATOMI and DEPLUSE split the 6 ratings 3 to 3. ATOMI has 4 outdoor models, DEPLUSE has 4 outdoor models. ATOMI and DEPLUSE have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ATOMI and DEPLUSE on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ATOMI and DEPLUSE split the 6 ratings 3 to 3.
  • ATOMI
  • DEPLUSE
  • Other ranked manufacturers
ATOMIDEPLUSE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingATOMIDEPLUSE
Efficiency index44% (higher)median —36% (higher)median —
COP at 5°F29%median 1.8476%median 2.13
Capacity retention at 5°F2%median 52%9%median 55%
HSPF216%median 8.617%median 8.5
SEER265% (higher)median 22.647% (higher)median 20.0
EER280% (higher)median 13.128% (higher)median 11.1
Heating capacity at 5°F33% (higher)median 8,250 Btu/h26% (higher)median 9,150 Btu/h
Outdoor models44
AHRI certifications46

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardATOMIDEPLUSE
CEE 2025 Tier 1 (Split ASHP)100%4 models50%2 models
CEE 2026 Tier 1 (Split ASHP)100%4 models50%2 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 1 groups where both have models
  • ATOMI
  • DEPLUSE
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeATOMIDEPLUSE
Ducted, up to 1.5 tonsNone1 · index 49%
Non-ducted, up to 1.5 tons4 · index 44%2 · index 30%
Non-ducted, 2 tonsNone1 · index 35%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeATOMICold-climate score, best modelDEPLUSECold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tonsNone on this board (0 of 4 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, 2 tonsNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeATOMIAll-around score, best modelDEPLUSEAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class48.9(50 is the typical model of its size class)DP-MS12DA-2OUwith ducted air handler DP-S12DA-2IN1 of 1 models have all five ratings · AHRI 218338367
Non-ducted, up to 1.5 tons45.8(50 is the typical model of its size class) (higher)AT2240with ductless indoor unit AT2240Also listed as AT2240 CA4 of 4 models have all five ratings · AHRI 21839992430.9(50 is the typical model of its size class)DP-MS12DA-1OUwith ductless indoor unit DP-S12DA-1IN2 of 2 models have all five ratings · AHRI 218338368
Non-ducted, 2 tonsNo models in this size class34.5(50 is the typical model of its size class)DP-MS24DA-OUwith ductless indoor unit DP-MS24DA-IN1 of 1 models have all five ratings · AHRI 218338370

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingATOMIDEPLUSE
COP at 5°Fbeats 49% · 1.91AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tonsbeats 86% · 2.20DP-MS18DA-OUNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 3% · 53%AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tonsbeats 15% · 64%DP-MS18DA-OUNon-ducted, up to 1.5 tons
HSPF2beats 26% · 8.9AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tonsbeats 27% · 8.5DP-MS12DA-2OUDucted, up to 1.5 tons
SEER2beats 74% · 23.9AT2239Also listed as AT2239 CANon-ducted, up to 1.5 tonsbeats 83% · 20.0DP-MS12DA-2OUDucted, up to 1.5 tons
EER2beats 78% · 13.2AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tonsbeats 37% · 11.4DP-MS12DA-2OUDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 59% · 10,100 Btu/hAT2240Also listed as AT2240 CANon-ducted, up to 1.5 tonsbeats 65% · 11,500 Btu/hDP-MS18DA-OUNon-ducted, up to 1.5 tons