ATOMI vs Villara heat pumps
Measured against models of the same size and duct type, Villara scores higher on 5 of the 6 ratings. ATOMI has 4 outdoor models, Villara has 4 outdoor models. ATOMI and Villara have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ATOMI
- Villara
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ATOMI | Villara |
|---|---|---|
| Efficiency index | 44%median — | 66%median — |
| COP at 5°F | 29%median 1.84 | 80%median 2.20 |
| Capacity retention at 5°F | 2%median 52% | 53%median 73% |
| HSPF2 | 16%median 8.6 | 74%median 9.3 |
| SEER2 | 65%median 22.6 | 75%median 18.5 |
| EER2 | 80% (higher)median 13.1 | 52% (higher)median 11.2 |
| Heating capacity at 5°F | 33%median 8,250 Btu/h | 52%median 30,000 Btu/h |
| Outdoor models | 4 | 4 |
| AHRI certifications | 4 | 4 |
Share of models meeting each standard
| Standard | ATOMI | Villara |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%4 models | 75%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%4 models | 75%3 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 75%3 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ATOMI
- Villara
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ATOMI | Villara |
|---|---|---|
| Ducted, 2 tons | None | 1 · index 79% |
| Ducted, 2.5 to 3 tons | None | 1 · index 66% |
| Ducted, 3.5 to 4.5 tons | None | 2 · index 60% |
| Non-ducted, up to 1.5 tons | 4 · index 44% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ATOMICold-climate score, best model | VillaraCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 65.0(50 is the typical model of its size class)VHP-UCHA-24HDCTwith ducted air handler VAH-UCHA-24HDC1 of 1 models qualify · AHRI 217081897 |
| Ducted, 2.5 to 3 tons | No models in this size class | 70.0(50 is the typical model of its size class)VHP-UCHA-36HDCTwith ducted air handler VAH-UCHA-36HDC1 of 1 models qualify · AHRI 217001204 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 73.5(50 is the typical model of its size class)VHP-UCHA-48HDCTwith ducted air handler VAH-UCHA-48HDC2 of 2 models qualify · AHRI 217081898 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 4 models qualify) | No models in this size class |
All-around best
| Size and duct type | ATOMIAll-around score, best model | VillaraAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 79.2(50 is the typical model of its size class)VHP-UCHA-24HDCTwith ducted air handler VAH-UCHA-24HDC1 of 1 models have all five ratings · AHRI 217081897 |
| Ducted, 2.5 to 3 tons | No models in this size class | 66.2(50 is the typical model of its size class)VHP-UCHA-36HDCTwith ducted air handler VAH-UCHA-36HDC1 of 1 models have all five ratings · AHRI 217001204 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 68.7(50 is the typical model of its size class)VHP-UCHA-48HDCTwith ducted air handler VAH-UCHA-48HDC2 of 2 models have all five ratings · AHRI 217081898 |
| Non-ducted, up to 1.5 tons | 45.8(50 is the typical model of its size class)AT2240with ductless indoor unit AT2240Also listed as AT2240 CA4 of 4 models have all five ratings · AHRI 218399924 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ATOMI | Villara |
|---|---|---|
| COP at 5°F | beats 49% · 1.91AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tons | beats 85% · 2.20VHP-UCHA-36HDCTDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 3% · 53%AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tons | beats 55% · 73%VHP-UCHA-36HDCTDucted, 2.5 to 3 tons |
| HSPF2 | beats 26% · 8.9AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tons | beats 84% · 9.8VHP-UCHA-48HDCTDucted, 3.5 to 4.5 tons |
| SEER2 | beats 74% · 23.9AT2239Also listed as AT2239 CANon-ducted, up to 1.5 tons | beats 86% · 20.0VHP-UCHA-24HDCTDucted, 2 tons |
| EER2 | beats 78% · 13.2AT2240Also listed as AT2240 CANon-ducted, up to 1.5 tons | beats 98% · 14.0VHP-UCHA-24HDCTDucted, 2 tons |
| Heating capacity at 5°F | beats 59% · 10,100 Btu/hAT2240Also listed as AT2240 CANon-ducted, up to 1.5 tons | beats 63% · 38,500 Btu/hVHP-UCHA-60HDCTDucted, 3.5 to 4.5 tons |