Skip to content

CONFORTOTAL vs ThinkAir heat pumps

Measured against models of the same size and duct type, CONFORTOTAL scores higher on 6 of the 6 ratings. CONFORTOTAL has 9 outdoor models, ThinkAir has 8 outdoor models. CONFORTOTAL and ThinkAir have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CONFORTOTAL and ThinkAir on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CONFORTOTAL scores higher on 6 of the 6 ratings.
  • CONFORTOTAL
  • ThinkAir
  • Other ranked manufacturers
CONFORTO…ThinkAir

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCONFORTOTALThinkAir
Efficiency index49% (higher)median —32% (higher)median —
COP at 5°F52% (higher)median 2.0033% (higher)median 1.85
Capacity retention at 5°F31% (higher)median 71%25% (higher)median 65%
HSPF252% (higher)median 9.544% (higher)median 9.5
SEER264% (higher)median 22.534% (higher)median 17.0
EER241% (higher)median 11.327% (higher)median 9.5
Heating capacity at 5°F37% (higher)median 16,000 Btu/h32% (higher)median 14,000 Btu/h
Outdoor models98
AHRI certifications98

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCONFORTOTALThinkAir
CEE 2025 Tier 1 (Split ASHP)77.8%7 models37.5%3 models
CEE 2026 Tier 1 (Split ASHP)77.8%7 models37.5%3 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)44.4%4 models37.5%3 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • CONFORTOTAL
  • ThinkAir
  • All models of the group
Non-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCONFORTOTALThinkAir
Non-ducted, up to 1.5 tons5 · index 46%4 · index 29%
Non-ducted, 2 tons1 · index 42%1 · index 15%
Non-ducted, 2.5 to 3 tons2 · index 59%3 · index 42%
Non-ducted, 3.5 to 4.5 tons1 · index 43%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCONFORTOTALCold-climate score, best modelThinkAirCold-climate score, best model
Non-ducted, up to 1.5 tons70.1(50 is the typical model of its size class)CICON182-MR1 of 5 models qualify · AHRI 21750027470.1(50 is the typical model of its size class)TFM2-18H1B1 of 4 models qualify · AHRI 217731083
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons58.2(50 is the typical model of its size class)CICON272-MR2 of 2 models qualify · AHRI 21750027558.2(50 is the typical model of its size class)TFM3-27H1B2 of 3 models qualify · AHRI 217731084
Non-ducted, 3.5 to 4.5 tons32.4(50 is the typical model of its size class)CICON422-MR1 of 1 models qualify · AHRI 217500277No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCONFORTOTALAll-around score, best modelThinkAirAll-around score, best model
Non-ducted, up to 1.5 tons73.9(50 is the typical model of its size class)CICON182-MR3 of 5 models have all five ratings · AHRI 21750027473.9(50 is the typical model of its size class)TFM2-18H1B4 of 4 models have all five ratings · AHRI 217731083
Non-ducted, 2 tons41.6(50 is the typical model of its size class) (higher)CICON242-INVwith ductless indoor unit ECICON242-INV1 of 1 models have all five ratings · AHRI 21750027314.6(50 is the typical model of its size class)TE17-24H1Bwith ductless indoor unit TE17-24H1A1 of 1 models have all five ratings · AHRI 217497279
Non-ducted, 2.5 to 3 tons65.9(50 is the typical model of its size class)CICON272-MR2 of 2 models have all five ratings · AHRI 21750027565.9(50 is the typical model of its size class)TFM3-27H1B3 of 3 models have all five ratings · AHRI 217731084
Non-ducted, 3.5 to 4.5 tons42.7(50 is the typical model of its size class)CICON422-MR1 of 1 models have all five ratings · AHRI 217500277No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCONFORTOTALThinkAir
COP at 5°Fbeats 70% · 2.10CICON242-INVNon-ducted, 2 tonsbeats 64% · 2.00TFM2-18H1BNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 63% · 80%CICON182-MRNon-ducted, up to 1.5 tonsbeats 63% · 80%TFM2-18H1BNon-ducted, up to 1.5 tons
HSPF2beats 81% · 10.5CICON182-MRNon-ducted, up to 1.5 tonsbeats 81% · 10.5TFM2-18H1BNon-ducted, up to 1.5 tons
SEER2beats 90% · 24.0CICON272-MRNon-ducted, 2.5 to 3 tonsbeats 90% · 24.0TFM3-27H1BNon-ducted, 2.5 to 3 tons
EER2beats 73% · 13.0CICON182-MRNon-ducted, up to 1.5 tonsbeats 73% · 13.0TFM2-18H1BNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 89% · 16,000 Btu/hCICON182-MRNon-ducted, up to 1.5 tonsbeats 89% · 16,000 Btu/hTFM2-18H1BNon-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter