Skip to content

ECO AC vs MAJOR HVAC SYSTEMS heat pumps

Measured against models of the same size and duct type, ECO AC scores higher on 3 of the 6 ratings. ECO AC has 22 outdoor models, MAJOR HVAC SYSTEMS has 21 outdoor models. ECO AC and MAJOR HVAC SYSTEMS have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ECO AC and MAJOR HVAC SYSTEMS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ECO AC scores higher on 3 of the 6 ratings.
  • ECO AC
  • MAJOR HVAC SYSTEMS
  • Other ranked manufacturers
ECO ACMAJOR HV…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingECO ACMAJOR HVAC SYSTEMS
Efficiency index59%median ——median —
COP at 5°F44%median 1.95—median —
Capacity retention at 5°F69%median 90%—median —
HSPF248% (higher)median 10.026% (higher)median 7.5
SEER264% (higher)median 21.021% (higher)median 14.3
EER265% (higher)median 12.351% (higher)median 11.4
Heating capacity at 5°F66%median 18,000 Btu/h—median —
Outdoor models2221
AHRI certifications3440

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardECO ACMAJOR HVAC SYSTEMS
CEE 2025 Tier 1 (Split ASHP)95.5%21 models0%0 models
CEE 2026 Tier 1 (Split ASHP)95.5%21 models0%0 models
CEE Advanced Tier (Split ASHP)13.6%3 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)95.5%21 models0%0 models
DOE Cold Climate Heat Pump Challenge13.6%3 models0%0 models
ENERGY STAR Cold Climate100%22 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • ECO AC
  • MAJOR HVAC SYSTEMS
  • All models of the group
Ducted, up to 1.5 tons1.901,935 modelsDucted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsNon-ducted, up to 1.5 tons1.944,075 modelsNon-ducted, 2 tons2.001,010 modelsNon-ducted, 2.5 to 3 tons2.001,234 modelsNon-ducted, 3.5 to 4.5 tons2.00600 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeECO ACMAJOR HVAC SYSTEMS
Ducted, up to 1.5 tons1 · index 41%3 · index —
Ducted, 2 tons1 · index 55%3 · index —
Ducted, 2.5 to 3 tons4 · index 58%6 · index —
Ducted, 3.5 to 4.5 tons1 · index 76%9 · index —
Non-ducted, up to 1.5 tons10 · index 63%None
Non-ducted, 2 tons4 · index 57%None
Non-ducted, 2.5 to 3 tons4 · index 53%None
Non-ducted, 3.5 to 4.5 tons2 · index 62%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeECO ACCold-climate score, best modelMAJOR HVAC SYSTEMSCold-climate score, best model
Ducted, up to 1.5 tons40.5(50 is the typical model of its size class)EMH-2O18KBB1 of 1 models qualify · AHRI 218461419None on this board (0 of 3 models qualify)
Ducted, 2 tons48.9(50 is the typical model of its size class)EMH-3O24KBB1 of 1 models qualify · AHRI 218461421None on this board (0 of 3 models qualify)
Ducted, 2.5 to 3 tons77.3(50 is the typical model of its size class)EHI-O36KBBwith ducted air handler EHI-V36KBB4 of 4 models qualify · AHRI 217258402None on this board (0 of 6 models qualify)
Ducted, 3.5 to 4.5 tons83.9(50 is the typical model of its size class)EHI-O60KBBwith ducted air handler EHI-V60KBB1 of 1 models qualify · AHRI 217258401None on this board (0 of 9 models qualify)
Non-ducted, up to 1.5 tons88.2(50 is the typical model of its size class)EHP-O09KBBwith ductless indoor unit EHP-W09KBB10 of 10 models qualify · AHRI 216772328No models in this size class
Non-ducted, 2 tons68.5(50 is the typical model of its size class)EMH-3O24KBB3 of 4 models qualify · AHRI 216772340No models in this size class
Non-ducted, 2.5 to 3 tons77.8(50 is the typical model of its size class)EMH-4O36KBB4 of 4 models qualify · AHRI 216772342No models in this size class
Non-ducted, 3.5 to 4.5 tons67.0(50 is the typical model of its size class)EMH-5O42KBB2 of 2 models qualify · AHRI 216772343No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeECO ACAll-around score, best modelMAJOR HVAC SYSTEMSAll-around score, best model
Ducted, up to 1.5 tons41.2(50 is the typical model of its size class)EMH-2O18KBB1 of 1 models have all five ratings · AHRI 218461419None on this board (0 of 3 models have all five ratings)
Ducted, 2 tons55.0(50 is the typical model of its size class)EMH-3O24KBB1 of 1 models have all five ratings · AHRI 218461421None on this board (0 of 3 models have all five ratings)
Ducted, 2.5 to 3 tons68.5(50 is the typical model of its size class)EHI-O36KBBwith ducted air handler EHI-V36KBB4 of 4 models have all five ratings · AHRI 217258402None on this board (0 of 6 models have all five ratings)
Ducted, 3.5 to 4.5 tons80.0(50 is the typical model of its size class)EHI-O60KBBwith ducted air handler EHI-V48KBB1 of 1 models have all five ratings · AHRI 217452743None on this board (0 of 9 models have all five ratings)
Non-ducted, up to 1.5 tons93.2(50 is the typical model of its size class)EHP-O09KBBwith ductless indoor unit EHP-W09KBB10 of 10 models have all five ratings · AHRI 216772328No models in this size class
Non-ducted, 2 tons78.8(50 is the typical model of its size class)EHP-O24KBBwith ductless indoor unit EHP-W24KBB4 of 4 models have all five ratings · AHRI 216772325No models in this size class
Non-ducted, 2.5 to 3 tons71.2(50 is the typical model of its size class)EMH-4O30KBB4 of 4 models have all five ratings · AHRI 216772341No models in this size class
Non-ducted, 3.5 to 4.5 tons67.8(50 is the typical model of its size class)EMH-5O42KBB2 of 2 models have all five ratings · AHRI 216772343No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingECO ACMAJOR HVAC SYSTEMS
COP at 5°Fbeats 87% · 2.10EMH-4O36KBBNon-ducted, 2.5 to 3 tons—
Capacity retention at 5°Fbeats 96% · 100%EHP-O24KBBNon-ducted, 2 tons—
HSPF2beats 88% · 11.2EHP-O09KBBNon-ducted, up to 1.5 tonsbeats 27% · 7.5MTD-H42SMR6Also listed as MTD-H42SMR6-C01/SE150, MTD-H42SMR3-C01/SE143Ducted, 3.5 to 4.5 tons
SEER2beats 99% · 27.0EHP-O24KBBNon-ducted, 2 tonsbeats 22% · 14.3MTD-H42SMR6Also listed as MTD-H42SMR6-C01/SE150, MTD-H42SMR3-C01/SE143Ducted, 3.5 to 4.5 tons
EER2beats 98% · 16.8EHP-O09KBBNon-ducted, up to 1.5 tonsbeats 56% · 11.4MTD-H42SMR6Also listed as MTD-H42SMR6-C01/SE150, MTD-H42SMR3-C01/SE143Ducted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 98% · 54,000 Btu/hEHI-O60KBBDucted, 3.5 to 4.5 tons—

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter