Skip to content

MAXI AIR vs OLMO heat pumps

Measured against models of the same size and duct type, MAXI AIR scores higher on 6 of the 6 ratings. MAXI AIR has 10 outdoor models, OLMO has 11 outdoor models. MAXI AIR and OLMO have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
MAXI AIR and OLMO on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, MAXI AIR scores higher on 6 of the 6 ratings.
  • MAXI AIR
  • OLMO
  • Other ranked manufacturers
MAXI AIROLMO

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMAXI AIROLMO
Efficiency index75% (higher)median —43% (higher)median —
COP at 5°F51% (higher)median 2.0045% (higher)median 1.98
Capacity retention at 5°F83% (higher)median 98%40% (higher)median 74%
HSPF283% (higher)median 10.533% (higher)median 9.0
SEER277% (higher)median 23.045% (higher)median 20.0
EER277% (higher)median 12.850% (higher)median 12.0
Heating capacity at 5°F84% (higher)median 27,000 Btu/h41% (higher)median 18,000 Btu/h
Outdoor models1011
AHRI certifications3417

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMAXI AIROLMO
CEE 2025 Tier 1 (Split ASHP)100%10 models90.9%10 models
CEE 2026 Tier 1 (Split ASHP)100%10 models81.8%9 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)100%10 models54.5%6 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate70%7 models36.4%4 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • MAXI AIR
  • OLMO
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMAXI AIROLMO
Ducted, up to 1.5 tons2 · index 77%None
Ducted, 2.5–3 tons5 · index 77%None
Ducted, 3.5–4.5 tons1 · index 49%None
Non-ducted, up to 1.5 tons4 · index 75%6 · index 43%
Non-ducted, 2.5–3 tons4 · index 76%3 · index 47%
Non-ducted, 2 tonsNone1 · index 34%
Non-ducted, 3.5–4.5 tonsNone1 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMAXI AIRCold-climate score, best modelOLMOCold-climate score, best model
Ducted, up to 1.5 tons70.8(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models qualify · AHRI 218381880No models in this size class
Ducted, 2.5–3 tons82.5(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models qualify · AHRI 217752780No models in this size class
Ducted, 3.5–4.5 tons60.5(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models qualify · AHRI 217752767No models in this size class
Non-ducted, up to 1.5 tons73.8(50 is the typical model of its size class) (higher)T55-AES18EXT454with ductless indoor unit T55-AES18INT4544 of 4 models qualify · AHRI 21775277369.5(50 is the typical model of its size class)OS-RMS18-230VO2 of 6 models qualify · AHRI 217739001
Non-ducted, 2 tonsNo models in this size class38.8(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models qualify · AHRI 218752476
Non-ducted, 2.5–3 tons78.0(50 is the typical model of its size class) (higher)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models qualify · AHRI 21775278153.7(50 is the typical model of its size class)OS-RMS36-230VO2 of 3 models qualify · AHRI 217739004
Non-ducted, 3.5–4.5 tonsNo models in this size class16.4(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models qualify · AHRI 217739003

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMAXI AIRAll-around score, best modelOLMOAll-around score, best model
Ducted, up to 1.5 tons77.4(50 is the typical model of its size class)T55-MULTI18E454Also listed as T55-MULTI18E4542 of 2 models have all five ratings · AHRI 218381880No models in this size class
Ducted, 2.5–3 tons83.6(50 is the typical model of its size class)T55-MULTI36E454Also listed as T55-MULTI36E4545 of 5 models have all five ratings · AHRI 217752780No models in this size class
Ducted, 3.5–4.5 tons49.1(50 is the typical model of its size class)MAXS-4260-454with ducted air handler AHMS-6020-4541 of 1 models have all five ratings · AHRI 217752767No models in this size class
Non-ducted, up to 1.5 tons81.9(50 is the typical model of its size class) (higher)T55-MULTI18E454Also listed as T55-MULTI18E4544 of 4 models have all five ratings · AHRI 21838187969.2(50 is the typical model of its size class)OS-RMS18-230VO6 of 6 models have all five ratings · AHRI 217739001
Non-ducted, 2 tonsNo models in this size class34.1(50 is the typical model of its size class)OS-SR24-230VOwith ductless indoor unit OS-A24SRW-230VI1 of 1 models have all five ratings · AHRI 218752476
Non-ducted, 2.5–3 tons78.3(50 is the typical model of its size class) (higher)T55-MULTI36E454Also listed as T55-MULTI36E4544 of 4 models have all five ratings · AHRI 21775277964.2(50 is the typical model of its size class)OS-RMS27-230VO3 of 3 models have all five ratings · AHRI 217739002
Non-ducted, 3.5–4.5 tonsNo models in this size class43.7(50 is the typical model of its size class)OS-RMS42-230VO1 of 1 models have all five ratings · AHRI 217739003

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMAXI AIROLMO
COP at 5°Fbeats 63% · 2.00T55-MULTI18E454Also listed as T55-MULTI18E454Ducted, up to 1.5 tonsbeats 100% · 2.53OS-SR18-230VONon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 107%MAXS-2430-454Ducted, 2.5–3 tonsbeats 87% · 100%OS-RMS18-230VONon-ducted, up to 1.5 tons
HSPF2beats 94% · 10.4T55-MULTI36E454Also listed as T55-MULTI36E454Ducted, 2.5–3 tonsbeats 64% · 10.0OS-RMS18-230VONon-ducted, up to 1.5 tons
SEER2beats 88% · 25.4T55-AES12EXT454Non-ducted, up to 1.5 tonsbeats 75% · 23.0OS-RMS27-230VONon-ducted, 2.5–3 tons
EER2beats 91% · 15.0T55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tonsbeats 80% · 12.9OS-RMS27-230VONon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 97% · 19,000 Btu/hT55-MULTI18E454Also listed as T55-MULTI18E454Non-ducted, up to 1.5 tonsbeats 93% · 18,000 Btu/hOS-RMS18-230VONon-ducted, up to 1.5 tons

More comparisons