Skip to content

MBO vs SINCLAIR AIR CONDITIONING heat pumps

Measured against models of the same size and duct type, SINCLAIR AIR CONDITIONING scores higher on 3 of the 6 ratings. MBO has 9 outdoor models, SINCLAIR AIR CONDITIONING has 9 outdoor models. MBO and SINCLAIR AIR CONDITIONING have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
MBO and SINCLAIR AIR CONDITIONING on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, SINCLAIR AIR CONDITIONING scores higher on 3 of the 6 ratings.
  • MBO
  • SINCLAIR AIR CONDITIONING
  • Other ranked manufacturers
MBOSINCLAIR…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingMBOSINCLAIR AIR CONDITIONING
Efficiency index—median —55%median —
COP at 5°F—median —78%median 2.18
Capacity retention at 5°F—median —25%median 52%
HSPF26%median 8.246%median 8.1
SEER225%median 18.142%median 15.5
EER233%median 10.877%median 13.0
Heating capacity at 5°F—median —27%median 16,800 Btu/h
Outdoor models99
AHRI certifications91,150

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardMBOSINCLAIR AIR CONDITIONING
CEE 2025 Tier 1 (Split ASHP)0%0 models33.3%3 models
CEE 2026 Tier 1 (Split ASHP)0%0 models33.3%3 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models11.1%1 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 0 groups where both have models
  • MBO
  • SINCLAIR AIR CONDITIONING
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeMBOSINCLAIR AIR CONDITIONING
Ducted, up to 1.5 tonsNone1 · index 51%
Ducted, 2 tonsNone1 · index 54%
Ducted, 2.5–3 tonsNone3 · index 53%
Ducted, 3.5–4.5 tonsNone3 · index 56%
Ducted, 5 tons and upNone1 · index 60%
Non-ducted, up to 1.5 tons7 · index —None
Non-ducted, 2 tons1 · index —None
Non-ducted, 2.5–3 tons1 · index —None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeMBOCold-climate score, best modelSINCLAIR AIR CONDITIONINGCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Ducted, 2 tonsNo models in this size class42.7(50 is the typical model of its size class)BH719M36P-**Awith ducted air handler BC724[C,U]BT-**+TDR1 of 2 models qualify · AHRI 217505027
Ducted, 2.5–3 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 3.5–4.5 tonsNo models in this size classNone on this board (0 of 3 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tonsNone on this board (0 of 7 models qualify)No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeMBOAll-around score, best modelSINCLAIR AIR CONDITIONINGAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class52.1(50 is the typical model of its size class)BH714S18P-**Awith indoor coil BC730HAT-**+TDR and furnace B80UR702E3A1 of 1 models have all five ratings · AHRI 216371993
Ducted, 2 tonsNo models in this size class68.5(50 is the typical model of its size class)BH719M36P-**Awith indoor coil BC724[C,U]BT-**+TDR and furnace B97UR702V3B2 of 2 models have all five ratings · AHRI 217547619
Ducted, 2.5–3 tonsNo models in this size class58.8(50 is the typical model of its size class)BH714S30P-**Awith ducted air handler BAH7E36PT-2 of 2 models have all five ratings · AHRI 216372131
Ducted, 3.5–4.5 tonsNo models in this size class60.7(50 is the typical model of its size class)BH714S42P-**Awith indoor coil BC748[C,U]CT-**+TDR and furnace B80UR901E5C3 of 3 models have all five ratings · AHRI 216372365
Ducted, 5 tons and upNo models in this size class66.7(50 is the typical model of its size class)BH714S60P-**Awith ducted air handler BAH7V60PT-1 of 1 models have all five ratings · AHRI 216372515
Non-ducted, up to 1.5 tonsNone on this board (0 of 7 models have all five ratings)No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingMBOSINCLAIR AIR CONDITIONING
COP at 5°F—beats 96% · 2.26BH714S60P-**ADucted, 5 tons and up
Capacity retention at 5°F—beats 52% · 54%BH714S60P-**ADucted, 5 tons and up
HSPF2beats 24% · 8.9MSAW-18HVCMNon-ducted, up to 1.5 tonsbeats 63% · 8.1BH714S60P-**ADucted, 5 tons and up
SEER2beats 72% · 23.9MSBW-12HVCNNon-ducted, up to 1.5 tonsbeats 87% · 20.0BH719M36P-**ADucted, 2 tons
EER2beats 76% · 13.2MSAW-18HVCMNon-ducted, up to 1.5 tonsbeats 99% · 13.4BH714S30P-**ADucted, 2.5–3 tons
Heating capacity at 5°F—beats 51% · 30,200 Btu/hBH714S60P-**ADucted, 5 tons and up

More comparisons