Skip to content

Ranked by EER2 only: 3.5–4.5 tons, by duct type

Cooling efficiency at a 95°F design day. This board ranks by that one rating; it is not the overall cold-climate verdict, which is the cold-climate board. Inside one size and duct type the raw ratings are comparable, so these boards rank by the rating itself, more than one model per manufacturer when they earn it. Only manufacturers with a QMID (IRS Qualified Manufacturer ID) on file are ranked.

New to heat pump ratings? The Simple view explains them in plain words →

LeaderboardsData as of updated · sources

Ducted, 3.5–4.5 tons: ranked by EER2 only

Ducted, 3.5–4.5 tons: ranked by EER2. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeEER2COP@5°FCap. 5/47HSPF2SEER2Btu/h @5°FMeetsCombosAHRI ref.
127TPA848A**30*CARRIER · 2-STAGE 18 SEER HPwith ducted air handler FT5ANBD60LAlso sold as Bryant Heating and Cooling Systems 248TAN048**AA, Bryant Heating and Cooling Systems PH8TAN548**AA, HEIL N5H8T48*K*AAA, Grandaire W5H8T48*K*AAA and 1 more; also listed as GH8TAN548**AACarrier4 tons48,500 Btu/h · Ducted13.52.3251%8.118.024,600CEE 25CEE 261,171215560636
27HP14F42P-**ADUCANEwith indoor coil H,A,DG49*60+TXV and furnace 80G2UH110CE16Also sold as Armstrong Air A7HP14F42P-**ALennox3.5 tons41,500 Btu/h · Ducted13.52.1252%7.815.219,800CEE 25CEE 26797216052247
3H5H8T48*K*AAA*HEIL · Mainline 18 SEER2 HPwith ducted air handler FTMA5B60L0DAlso sold as Comfortmaker C5H8T48*K*AAA, Kenmore (C,H,T)5H8T48*K*AAA, Tempstar T5H8T48*K*AAACarrier4 tons48,500 Btu/h · Ducted13.52.3451%8.118.024,600CEE 25CEE 261,899216151902
4ML14KP1-042-230A**LENNOXwith indoor coil L*42/60Z*+TXV and furnace SL280UH080NV60CAlso listed as EL16KP1-042-230ALennox3.5 tons41,500 Btu/h · Ducted13.52.1053%7.815.220,000None781216967721
5NS16H42SA5-**AGEwith indoor coil PL60H210P19*+TXV and furnace NF80X100V5CGE Appliances3.5 tons41,500 Btu/h · Ducted13.52.1053%7.815.220,200None267217454795
6BH714S42P-**AAC PROwith indoor coil PL60H210P19*+TXV and furnace B80UR1002V5CXGree3.5 tons41,500 Btu/h · Ducted13.52.1053%7.815.220,200None380217904847
727VPA948A*030*CARRIER · Performance 19 SEER2 VS HPwith ducted air handler FT5BD6021XAlso sold as Bryant Heating and Cooling Systems 249VAN048**AA, HEIL N5H9V48*K*AAA, HEIL Q5H9V48*K*AAACarrier4 tons46,000 Btu/h · Ducted13.52.1276%10.019.038,500CEE 25CEE 26XcelES CC642218695553
8EL21KLV-048-230A**LENNOX · Elite EL21KLV SERIESwith indoor coil CK40HT-48B-**+TDR and furnace SL280UH090V48BLennox4 tons47,500 Btu/h · Ducted13.42.0469%8.519.532,200CEE 25CEE 26XcelES CC570217117098
9A7CP21V48P-**AARMSTRONG AIR · A7CP21V Serieswith indoor coil 7EH48BX-**+TDR and furnace A80US2V090B16Lennox4 tons47,500 Btu/h · Ducted13.42.0568%8.519.532,200CEE 25CEE 26XcelES CC673217120482
10A7CP21V48P-**AAC PRO · A7CP21V Serieswith indoor coil 7EH48BX-**+TDR and furnace A80US2V090B16Gree4 tons47,500 Btu/h · Ducted13.42.0469%8.519.532,200CEE 25CEE 26XcelES CC126217465839

Ducted, 3.5–4.5 tons board

Non-ducted, 3.5–4.5 tons: ranked by EER2 only

Non-ducted, 3.5–4.5 tons: ranked by EER2. Every model here is the same size and duct type, so the raw values are comparable. Ties go to the lower AHRI reference number; every number in a row is from that row’s certification.
# · Outdoor modelManufacturerSize · typeEER2COP@5°FCap. 5/47HSPF2SEER2Btu/h @5°FMeetsCombosAHRI ref.
1KUMXA421ALG · KUMXA421ALG3.5 tons42,000 Btu/h · Non-ducted13.82.29100%11.021.548,000CEE 25CEE 26CEE AdvXcelDOEES CC3215402347
2KUSXA421ALG · KUSXA421Awith ductless indoor unit KNSCB421ALG3.5 tons42,000 Btu/h · Non-ducted13.52.2091%10.821.543,500CEE 25CEE 26XcelES CC2214837930
3ZRUM048GSS0LG · ZRUM048GSS0LG4 tons48,000 Btu/h · Non-ducted13.52.10100%10.323.354,000CEE 25CEE 26CEE AdvXcelDOEES CC3214914947
4GMV-V48WL/NHC-T(U)GREE · Ultra Heat GMV6 MiniAlso sold as Tosot TMV-V48WL/NHC-T(U)Gree4 tons48,000 Btu/h · Non-ducted13.52.3070%9.023.538,000CEE 25CEE 26XcelES CC3217123444
5MXZ-SM42NLHZ***Mitsubishi Electric · Smart MultiAlso listed as PUMY-HL42NKMU, MXZ-SM42NLHZ-Mitsubishi Electric3.5 tons42,000 Btu/h · Non-ducted13.42.00100%11.121.548,000CEE 25CEE 26XcelES CC3215685465
6MCY-MUB0488HS2P-ULTOSHIBA CARRIER · MCY-MUB0488HS2P-ULCarrier4 tons48,000 Btu/h · Non-ducted13.42.5070%11.324.438,000CEE 25CEE 26XcelES CC5216760288
7KUSXB421ALG · KUSXB421Awith ductless indoor unit KNSCB421ALG3.5 tons42,000 Btu/h · Non-ducted13.21.9883%10.821.040,000CEE 25CEE 26XcelES CC30214837927
8KUMXA481ALG · KUMXA481ALG4 tons48,000 Btu/h · Non-ducted13.12.34100%10.520.552,500CEE 25CEE 26CEE AdvXcelDOEES CC3215408636
9MXZ-SM48NLHZ***Mitsubishi Electric · Smart MultiAlso listed as PUMY-HL48NKMU, MXZ-SM48NLHZ-Mitsubishi Electric4 tons48,000 Btu/h · Non-ducted13.12.00100%11.523.054,000CEE 25CEE 26XcelES CC4215685467
10GWHD(42)ND6MOGREE · M-SeriesAlso sold as Tosot TM42H32MO, Kinghome KM42X6O, Tosot TM42D6MO, Tosot TMSCI7H4R42 and 5 more; also listed as MUL42HP230V1R32AO, GS5M42HP230V1MOGree3.5 tons42,000 Btu/h · Non-ducted13.02.1090%10.021.037,800CEE 25CEE 26XcelES CC3214931590

Non-ducted, 3.5–4.5 tons board

Download CSV of these EER2 boardsEvery board above in one file, ranked by value within each peer group.

Typical EER2 by size and duct type

The median model of each peer group. The spread between groups is why models are only compared within their own.
EER2 by size and duct typeEvery model, one row per peer group; the highlighted row is the one on this board · Low-GWP (R-454B, R-32)
  • All models of the group (shape)
  • Median and middle 50% / 80%
  • Leaderboard models
Ducted, 3.5–4.5 tons11.12,607 modelsNon-ducted, 3.5–4.5 tons11.9570 modelsmedian

Source: AHRI Directory · as of

Median EER2 of the representative certification, per peer group
Peer groupModelsMedian EER2
Ducted, up to 1.5 tons1,82711.7
Ducted, 2 tons1,15211.7
Ducted, 2.5–3 tons2,19811.5
Ducted, 3.5–4.5 tons2,60711.1
Ducted, 5 tons and up45811.0
Non-ducted, up to 1.5 tons3,56812.3
Non-ducted, 2 tons90312.0
Non-ducted, 2.5–3 tons1,14012.0
Non-ducted, 3.5–4.5 tons57011.9
Non-ducted, 5 tons and up8510.0