Skip to content

Clima Start heat pump efficiency: 3 outdoor models compared

Clima Start has 3 heat pump outdoor models certified with this refrigerant group, in 3 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Clima Start makes. Clima Start has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

Simple view, for homeowners: top picks by size and what each rating measures →

ManufacturerData as of updated · sources

Outdoor models
3
AHRI certifications
3
Efficiency index
65%
Typical model vs same-size, same-type peers (3 models)
Meet CEE 2025
100%
3 models

How Clima Start compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
Clima Start against every ranked manufacturerPeer scores, 0 to 100 · grey ticks: each ranked manufacturer · shaded: the middle half of Clima Start’s own modelsClima Start is strongest on capacity retention at 5°F (its typical model beats 93% of comparable models) and weakest on COP at 5°F (29%).
  • Clima Start
  • Middle half of its models
  • Other ranked manufacturers
Clima St…

Source: AHRI Directory, NEEP · as of

Average peer percentile of Clima Start’s models
RatingBeats comparable modelsRankRaw median
Efficiency index3 models scored65%Not ranked—
COP at 5°F3 models scored29%Not ranked1.85
Capacity retention at 5°F3 models scored93%Not ranked100%
HSPF23 models scored81%Not ranked9.5
SEER23 models scored74%Not ranked18.0
EER23 models scored49%Not ranked11.0
Heating capacity at 5°F3 models scored89%Not ranked36,000 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
Clima Start’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th to 90th percentile line
  • Clima Start (median, middle 50%, 10th to 90th)
  • All models of the group
Ducted, 2 tons2.001,155 modelsDucted, 2.5 to 3 tons2.002,059 modelsDucted, 3.5 to 4.5 tons2.002,330 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, 2 tons170%28%84%76%
Ducted, 2.5 to 3 tons158%25%79%69%
Ducted, 3.5 to 4.5 tons165%33%80%77%

Every Clima Start model in the market

Clima Start’s 3 models with a known size and duct type, over the shape of the whole catalog.
Clima Start models by size and ratingColoured: Clima Start · grey shapes: all 15,936 models · lines: catalog medians by size
  • Clima Start models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 3 clima start models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 15,936 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8971.641.711.751.852.24
Ducted, 1 ton4631.801.862.002.412.44
Ducted, 1.5 tons1,0351.751.822.002.202.40
Ducted, 2 tons1,0731.751.862.002.182.30
Ducted, 2.5 tons1,1361.701.802.002.102.36
Ducted, 3 tons7361.801.902.002.102.42
Ducted, 3.5 tons8981.701.802.002.102.46
Ducted, 4 tons7691.801.852.002.122.39
Ducted, 4.5 tons7241.701.801.902.102.20
Ducted, 5 tons911.892.002.102.102.10
Non-ducted, 0.5 tons1,3821.751.801.902.002.21
Non-ducted, 1 ton1,6201.801.801.952.102.21
Non-ducted, 1.5 tons1,4831.801.802.002.102.28
Non-ducted, 2 tons8611.801.982.002.102.30
Non-ducted, 2.5 tons4541.801.882.002.002.21
Non-ducted, 3 tons5221.801.972.002.032.20
Non-ducted, 3.5 tons3042.002.002.002.052.10
Non-ducted, 4 tons2141.962.002.052.102.11
Non-ducted, 4.5 tons801.901.911.962.012.01
Non-ducted, 5 tons881.992.042.052.202.20

Source: AHRI Directory · as of

Top Clima Start models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 3 Clima Start cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1CS-CEN-48HHR32-OClima Startwith ducted air handler CS-CEN-48AH4 tons48,000 Btu/h · Ducted100%1.859.548,00018.0CEE 25CEE 26Xcel1218867280Ducted, 3.5 to 4.5 tons69.4
2CS-CEN-24HHR32-OClima Startwith ducted air handler CS-CEN-24AH2 tons24,000 Btu/h · Ducted100%1.8510.024,00019.0CEE 25CEE 26Xcel1218867278Ducted, 2 tons68.8
3CS-CEN-36HHR32-OClima Startwith ducted air handler CS-CEN-36AH3 tons36,000 Btu/h · Ducted100%1.859.536,00018.0CEE 25CEE 26Xcel1218867279Ducted, 2.5 to 3 tons64.2

All-around best

Top 3 Clima Start models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1CS-CEN-24HHR32-OClima Startwith ducted air handler CS-CEN-24AH2 tons24,000 Btu/h · Ducted100%1.8510.019.012.0CEE 25CEE 26Xcel1218867278Ducted, 2 tons70.168.871.468.8
2CS-CEN-48HHR32-OClima Startwith ducted air handler CS-CEN-48AH4 tons48,000 Btu/h · Ducted100%1.859.518.011.0CEE 25CEE 26Xcel1218867280Ducted, 3.5 to 4.5 tons65.469.461.369.4
3CS-CEN-36HHR32-OClima Startwith ducted air handler CS-CEN-36AH3 tons36,000 Btu/h · Ducted100%1.859.518.011.0CEE 25CEE 26Xcel1218867279Ducted, 2.5 to 3 tons58.064.251.764.2

Best model on each rating

Clima Start’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FCS-CEN-48HHR32-O1.85Ducted, 3.5 to 4.5 tons33%218867280
Capacity retention at 5°FCS-CEN-48HHR32-O100%Ducted, 3.5 to 4.5 tons94%218867280
HSPF2CS-CEN-24HHR32-O10.0Ducted, 2 tons81%218867278
SEER2CS-CEN-48HHR32-O18.0Ducted, 3.5 to 4.5 tons76%218867280
EER2CS-CEN-24HHR32-O12.0Ducted, 2 tons62%218867278
Heating capacity at 5°FCS-CEN-24HHR32-O24,000 Btu/hDucted, 2 tons89%218867278

All 3 Clima Start models in Explore

Clima Start size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
Clima Start: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are kept)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, 2 tons68.8(50 is the typical model of its size class)CS-CEN-24HHR32-Owith ducted air handler CS-CEN-24AH1 of 1 models qualify · AHRI 21886727870.1(50 is the typical model of its size class)CS-CEN-24HHR32-Owith ducted air handler CS-CEN-24AH1 of 1 models have all five ratings · AHRI 218867278
Ducted, 2.5 to 3 tons64.2(50 is the typical model of its size class)CS-CEN-36HHR32-Owith ducted air handler CS-CEN-36AH1 of 1 models qualify · AHRI 21886727958.0(50 is the typical model of its size class)CS-CEN-36HHR32-Owith ducted air handler CS-CEN-36AH1 of 1 models have all five ratings · AHRI 218867279
Ducted, 3.5 to 4.5 tons69.4(50 is the typical model of its size class)CS-CEN-48HHR32-Owith ducted air handler CS-CEN-48AH1 of 1 models qualify · AHRI 21886728065.4(50 is the typical model of its size class)CS-CEN-48HHR32-Owith ducted air handler CS-CEN-48AH1 of 1 models have all five ratings · AHRI 218867280

All-around board, every manufacturer

Newest Clima Start certifications

By AHRI reference number; AHRI issues references in increasing order.
The 3 most recently certified Clima Start outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
CS-CEN-48HHR32-OClima Startwith ducted air handler CS-CEN-48AH4 tons48,000 Btu/h · Ducted1.85100%9.518.0CEE 25CEE 26Xcel1218867280
CS-CEN-36HHR32-OClima Startwith ducted air handler CS-CEN-36AH3 tons36,000 Btu/h · Ducted1.85100%9.518.0CEE 25CEE 26Xcel1218867279
CS-CEN-24HHR32-OClima Startwith ducted air handler CS-CEN-24AH2 tons24,000 Btu/h · Ducted1.85100%10.019.0CEE 25CEE 26Xcel1218867278

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

No shared hardware found for Clima Start in this group.

Compare Clima Start

Manufacturers of a similar size, side by side.

Clima Start includes these brand names as listed in AHRI: Clima Start. Standards are checked against published thresholds; program rules beyond ratings are not checked.