Both views use the same certified data. This device remembers your choice.
CAAIR vs Clima Start heat pumps
Measured against models of the same size and duct type, Clima Start scores higher on 4 of the 6 ratings. CAAIR has 3 outdoor models, Clima Start has 3 outdoor models. CAAIR and Clima Start have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CAAIR
- Clima Start
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CAAIR | Clima Start |
|---|---|---|
| Efficiency index | —median — | 65%median — |
| COP at 5°F | 67% (higher)median 2.08 | 29% (higher)median 1.85 |
| Capacity retention at 5°F | —median — | 93%median 100% |
| HSPF2 | 19%median 8.5 | 81%median 9.5 |
| SEER2 | 21%median 19.0 | 74%median 18.0 |
| EER2 | 20%median 10.5 | 49%median 11.0 |
| Heating capacity at 5°F | 0%median 3,600 Btu/h | 89%median 36,000 Btu/h |
| Outdoor models | 3 | 3 |
| AHRI certifications | 3 | 3 |
Share of models meeting each standard
| Standard | CAAIR | Clima Start |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 100%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 100%3 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 100%3 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CAAIR
- Clima Start
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CAAIR | Clima Start |
|---|---|---|
| Ducted, 2 tons | None | 1 · index 70% |
| Ducted, 2.5 to 3 tons | None | 1 · index 58% |
| Ducted, 3.5 to 4.5 tons | None | 1 · index 65% |
| Non-ducted, up to 1.5 tons | 3 · index — | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CAAIRCold-climate score, best model | Clima StartCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 68.8(50 is the typical model of its size class)CS-CEN-24HHR32-Owith ducted air handler CS-CEN-24AH1 of 1 models qualify · AHRI 218867278 |
| Ducted, 2.5 to 3 tons | No models in this size class | 64.2(50 is the typical model of its size class)CS-CEN-36HHR32-Owith ducted air handler CS-CEN-36AH1 of 1 models qualify · AHRI 218867279 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 69.4(50 is the typical model of its size class)CS-CEN-48HHR32-Owith ducted air handler CS-CEN-48AH1 of 1 models qualify · AHRI 218867280 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models qualify) | No models in this size class |
All-around best
| Size and duct type | CAAIRAll-around score, best model | Clima StartAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 70.1(50 is the typical model of its size class)CS-CEN-24HHR32-Owith ducted air handler CS-CEN-24AH1 of 1 models have all five ratings · AHRI 218867278 |
| Ducted, 2.5 to 3 tons | No models in this size class | 58.0(50 is the typical model of its size class)CS-CEN-36HHR32-Owith ducted air handler CS-CEN-36AH1 of 1 models have all five ratings · AHRI 218867279 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 65.4(50 is the typical model of its size class)CS-CEN-48HHR32-Owith ducted air handler CS-CEN-48AH1 of 1 models have all five ratings · AHRI 218867280 |
| Non-ducted, up to 1.5 tons | None on this board (0 of 3 models have all five ratings) | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CAAIR | Clima Start |
|---|---|---|
| COP at 5°F | beats 86% · 2.20ASW-2-JL18KNon-ducted, up to 1.5 tons | beats 33% · 1.85CS-CEN-48HHR32-ODucted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | — | beats 94% · 100%CS-CEN-48HHR32-ODucted, 3.5 to 4.5 tons |
| HSPF2 | beats 30% · 9.0ASW-2-JL18KNon-ducted, up to 1.5 tons | beats 81% · 10.0CS-CEN-24HHR32-ODucted, 2 tons |
| SEER2 | beats 32% · 20.0ASW-3-JL12KNon-ducted, up to 1.5 tons | beats 76% · 18.0CS-CEN-48HHR32-ODucted, 3.5 to 4.5 tons |
| EER2 | beats 31% · 11.0ASW-3-JL12KNon-ducted, up to 1.5 tons | beats 62% · 12.0CS-CEN-24HHR32-ODucted, 2 tons |
| Heating capacity at 5°F | beats 0% · 3,600 Btu/hASW-2-JL18KNon-ducted, up to 1.5 tons | beats 89% · 24,000 Btu/hCS-CEN-24HHR32-ODucted, 2 tons |