Skip to content

COOLPRO heat pump efficiency: 4 outdoor models compared

COOLPRO has 4 heat pump outdoor models certified with this refrigerant group, in 4 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes COOLPRO makes. COOLPRO has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.

New to heat pump ratings? The Simple view explains them in plain words →

ManufacturerData as of updated · sources

Outdoor models
4
AHRI certifications
4
Efficiency index
22%
Typical model vs same-size, same-type peers (4 models)
Meet CEE 2025
0%
0 models

How COOLPRO compares with comparable models

For each rating: the share of same-size, same-type models that a typical model of this manufacturer beats (50% is typical), its rank, and the raw median for context. Raw medians are not comparable across manufacturers that make different sizes.
COOLPRO against every ranked manufacturerPeer scores, 0–100 · grey ticks: each ranked manufacturer · shaded: the middle half of COOLPRO’s own modelsCOOLPRO is strongest on heating capacity at 5°F (its typical model beats 47% of comparable models) and weakest on EER2 (6%).
  • COOLPRO
  • Middle half of its models
  • Other ranked manufacturers
COOLPRO

Source: AHRI Directory, NEEP · as of

Average peer percentile of COOLPRO’s models
RatingBeats comparable modelsRankRaw median
Efficiency index4 models scored22%Not ranked—
COP at 5°F4 models scored15%Not ranked1.72
Capacity retention at 5°F4 models scored44%Not ranked70%
HSPF24 models scored32%Not ranked7.6
SEER24 models scored21%Not ranked14.2
EER24 models scored6%Not ranked9.0
Heating capacity at 5°F4 models scored47%Not ranked26,600 Btu/h

Standards met

Sizes and duct types offered

Models per peer group, and how they score against the other models of that group.
COOLPRO’s models inside each size and duct typeShape: every model of the group · blue: the middle half of this manufacturer’s models there, median dot, 10th–90th percentile line
  • COOLPRO (median, middle 50%, 10th–90th)
  • All models of the group
Ducted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsmedian

Source: AHRI Directory · as of

Share of comparable models beaten, per peer group
Size and duct typeModelsIndexCOP@5°FHSPF2SEER2
Ducted, 2 tons121%8%12%28%
Ducted, 2.5–3 tons111%3%17%14%
Ducted, 3.5–4.5 tons228%25%50%20%

Every COOLPRO model in the market

COOLPRO’s 4 models with a known size and duct type, over the shape of the whole catalog.
COOLPRO models by size and ratingColoured: COOLPRO · grey shapes: all 14,508 models · lines: catalog medians by size
  • COOLPRO models
  • Ducted median by size
  • Non-ducted median by size
  • Every model at each size (width = count)
  • Standard threshold

Dots: 4 coolpro models, each through its representative certification, in the colour of the rating shown. The grey shapes count all 14,508 models, half a ton at a time.
Show the data as a table
COP at 5°F by size and duct type (every model, by rated cooling capacity)
Duct type, sizeModels10th pct.25thMedian75th90th
Ducted, 0.5 tons8261.641.711.751.852.24
Ducted, 1 ton4071.801.902.052.412.45
Ducted, 1.5 tons9921.751.862.002.172.40
Ducted, 2 tons9991.751.862.002.182.30
Ducted, 2.5 tons1,0401.701.802.002.102.36
Ducted, 3 tons6961.801.902.002.102.42
Ducted, 3.5 tons8641.701.802.002.102.46
Ducted, 4 tons7271.801.862.002.122.40
Ducted, 4.5 tons6901.701.801.902.102.20
Ducted, 5 tons861.892.002.102.102.10
Non-ducted, 0.5 tons1,1861.751.801.902.002.22
Non-ducted, 1 ton1,3431.801.801.992.102.21
Non-ducted, 1.5 tons1,2611.801.802.002.102.31
Non-ducted, 2 tons7611.801.982.002.102.30
Non-ducted, 2.5 tons4031.801.852.002.002.10
Non-ducted, 3 tons4731.901.982.002.032.20
Non-ducted, 3.5 tons2802.002.002.002.052.10
Non-ducted, 4 tons2041.962.002.052.102.11
Non-ducted, 4.5 tons781.901.911.952.012.01
Non-ducted, 5 tons841.992.002.052.202.20

Source: AHRI Directory · as of

Top COOLPRO models

Its top five cold-climate picks and its top five all-around models across sizes (both scores compare each model with models of its own size and duct type, so sizes compare), then, on each single rating, the model that beats the largest share of comparable models.

Cold-climate picks

Top 2 COOLPRO cold-climate picks across sizes. Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2Btu/h @5°FSEER2MeetsCombosAHRI ref.Compared withScore
1CP48HPINV15PUCOOLPRO4 tons48,000 Btu/h · Ducted72%1.828.234,60014.6None1217992589Ducted, 3.5–4.5 tons45.5
2CP24HPINV15PUCOOLPRO2 tons24,000 Btu/h · Ducted77%1.647.218,50015.2None1217992587Ducted, 2 tons25.4

All-around best

Top 4 COOLPRO models on the all-around score across sizes. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
# · Outdoor modelSize · typeCap. 5/47COP@5°FHSPF2SEER2EER2MeetsCombosAHRI ref.Compared withScoreHeating halfCooling halfCold-climate score
1CP48HPINV15PUCOOLPRO4 tons48,000 Btu/h · Ducted72%1.828.214.69.3None1217992589Ducted, 3.5–4.5 tons34.145.522.745.5
2CP60HPINV15PUCOOLPRO4.5 tons55,000 Btu/h · Ducted68%1.808.013.48.6None1217992590Ducted, 3.5–4.5 tons21.536.96.2Not a pick
3CP24HPINV15PUCOOLPRO2 tons24,000 Btu/h · Ducted77%1.647.215.29.9None1217992587Ducted, 2 tons21.225.417.125.4
4CP36HPINV15PUCOOLPRO3 tons34,600 Btu/h · Ducted52%1.587.113.88.2None1217992588Ducted, 2.5–3 tons10.914.47.4Not a pick

Best model on each rating

COOLPRO’s model with the highest peer percentile on each rating, ranked by that one rating only
RatingModelValueCompared withBeatsAHRI ref.
COP at 5°FCP48HPINV15PU1.82Ducted, 3.5–4.5 tons28%217992589
Capacity retention at 5°FCP24HPINV15PU77%Ducted, 2 tons53%217992587
HSPF2CP48HPINV15PU8.2Ducted, 3.5–4.5 tons51%217992589
SEER2CP48HPINV15PU14.6Ducted, 3.5–4.5 tons28%217992589
EER2CP48HPINV15PU9.3Ducted, 3.5–4.5 tons11%217992589
Heating capacity at 5°FCP60HPINV15PU39,000 Btu/hDucted, 3.5–4.5 tons64%217992590

All 4 COOLPRO models in Explore

COOLPRO size class by size class: cold-climate and all-around

Its best model on each board in every size and duct type it makes. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there). Cold-climate picks must keep at least 70% of their heat at 5°F; the all-around score needs all five ratings and has no such bar.
COOLPRO: best cold-climate pick and best all-around model per size and duct type, with how many of its models are on each board (top 5 and 5 per class are in the snapshot)
Size and duct typeCold-climate pickCold-climate score, best modelAll-around bestAll-around score, best model
Ducted, 2 tons25.4(50 is the typical model of its size class)CP24HPINV15PU1 of 1 models qualify · AHRI 21799258721.2(50 is the typical model of its size class)CP24HPINV15PU1 of 1 models have all five ratings · AHRI 217992587
Ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)10.9(50 is the typical model of its size class)CP36HPINV15PU1 of 1 models have all five ratings · AHRI 217992588
Ducted, 3.5–4.5 tons45.5(50 is the typical model of its size class)CP48HPINV15PU1 of 2 models qualify · AHRI 21799258934.1(50 is the typical model of its size class)CP48HPINV15PU2 of 2 models have all five ratings · AHRI 217992589

All-around board, every manufacturer

Newest COOLPRO certifications

By AHRI reference number; AHRI issues references in increasing order.
The 4 most recently certified COOLPRO outdoor models
Outdoor modelSize · typeCOP@5°FCap. 5/47HSPF2SEER2MeetsCombosAHRI ref.
CP60HPINV15PUCOOLPRO4.5 tons55,000 Btu/h · Ducted1.8068%8.013.4None1217992590
CP48HPINV15PUCOOLPRO4 tons48,000 Btu/h · Ducted1.8272%8.214.6None1217992589
CP36HPINV15PUCOOLPRO3 tons34,600 Btu/h · Ducted1.5852%7.113.8None1217992588
CP24HPINV15PUCOOLPRO2 tons24,000 Btu/h · Ducted1.6477%7.215.2None1217992587

Shares hardware with

Manufacturers whose models are the same equipment under another badge. About OEM families

Compare COOLPRO

Manufacturers of a similar size, side by side.

COOLPRO includes these brand names as listed in AHRI: COOLPRO. Standards are checked against published thresholds; program rules beyond ratings are not checked.