Emeric heat pump efficiency: 4 outdoor models compared
Emeric has 4 heat pump outdoor models certified with this refrigerant group, in 6 AHRI-certified combinations. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes Emeric makes. Emeric has no QMID (IRS Qualified Manufacturer ID) on file, so it is not ranked against other manufacturers.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 4
- AHRI certifications
- 6
- Efficiency index
- 70%
- Typical model vs same-size, same-type peers (4 models)
- Meet CEE 2025
- 100%
- 4 models
How Emeric compares with comparable models
- Emeric
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index4 models scored | 70% | Not ranked | — |
| COP at 5°F4 models scored | 79% | Not ranked | 2.23 |
| Capacity retention at 5°F4 models scored | 57% | Not ranked | 76% |
| HSPF24 models scored | 63% | Not ranked | 9.0 |
| SEER24 models scored | 74% | Not ranked | 18.5 |
| EER24 models scored | 74% | Not ranked | 12.0 |
| Heating capacity at 5°F4 models scored | 51% | Not ranked | 26,500 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100% | 4 |
| CEE 2026 Tier 1 (Split ASHP) | 100% | 4 |
| CEE Advanced Tier (Split ASHP) | 0% | 0 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100% | 4 |
| DOE Cold Climate Heat Pump Challenge | 0% | 0 |
| ENERGY STAR Cold Climate | 100% | 4 |
Sizes and duct types offered
- Emeric (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, 2 tons | 2 | 68% | 71% | 50% | 66% |
| Ducted, 3.5–4.5 tons | 2 | 73% | 86% | 76% | 82% |
Every Emeric model in the market
- Emeric models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 826 | 1.64 | 1.71 | 1.75 | 1.85 | 2.24 |
| Ducted, 1 ton | 407 | 1.80 | 1.90 | 2.05 | 2.41 | 2.45 |
| Ducted, 1.5 tons | 992 | 1.75 | 1.86 | 2.00 | 2.17 | 2.40 |
| Ducted, 2 tons | 999 | 1.75 | 1.86 | 2.00 | 2.18 | 2.30 |
| Ducted, 2.5 tons | 1,040 | 1.70 | 1.80 | 2.00 | 2.10 | 2.36 |
| Ducted, 3 tons | 696 | 1.80 | 1.90 | 2.00 | 2.10 | 2.42 |
| Ducted, 3.5 tons | 865 | 1.70 | 1.80 | 2.00 | 2.10 | 2.46 |
| Ducted, 4 tons | 726 | 1.80 | 1.86 | 2.00 | 2.12 | 2.41 |
| Ducted, 4.5 tons | 690 | 1.70 | 1.80 | 1.90 | 2.10 | 2.20 |
| Ducted, 5 tons | 86 | 1.89 | 2.00 | 2.10 | 2.10 | 2.10 |
| Non-ducted, 0.5 tons | 1,186 | 1.75 | 1.80 | 1.90 | 2.00 | 2.22 |
| Non-ducted, 1 ton | 1,343 | 1.80 | 1.80 | 1.99 | 2.10 | 2.21 |
| Non-ducted, 1.5 tons | 1,261 | 1.80 | 1.80 | 2.00 | 2.10 | 2.31 |
| Non-ducted, 2 tons | 761 | 1.80 | 1.98 | 2.00 | 2.10 | 2.30 |
| Non-ducted, 2.5 tons | 403 | 1.80 | 1.85 | 2.00 | 2.00 | 2.10 |
| Non-ducted, 3 tons | 473 | 1.90 | 1.98 | 2.00 | 2.03 | 2.20 |
| Non-ducted, 3.5 tons | 280 | 2.00 | 2.00 | 2.00 | 2.05 | 2.10 |
| Non-ducted, 4 tons | 204 | 1.96 | 2.00 | 2.05 | 2.10 | 2.11 |
| Non-ducted, 4.5 tons | 78 | 1.90 | 1.91 | 1.95 | 2.01 | 2.01 |
| Non-ducted, 5 tons | 84 | 1.99 | 2.00 | 2.05 | 2.20 | 2.20 |
Source: AHRI Directory · as of
Top Emeric models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ETD-H60DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR3 | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 34,000 | 18.5 | CEE 25CEE 26XcelES CC | 2 | 216699937 | Ducted, 3.5–4.5 tons | 72.2 |
| 2ETD-H36DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR3 | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 8.8 | 19,000 | 18.5 | CEE 25CEE 26XcelES CC | 2 | 216699935 | Ducted, 2 tons | 60.2 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1ETD-H60DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR3 | 4 tons47,000 Btu/h · Ducted | 72% | 2.30 | 9.2 | 18.5 | 11.5 | CEE 25CEE 26XcelES CC | 2 | 216699937 | Ducted, 3.5–4.5 tons | 72.6 | 72.2 | 73.0 | 72.2 |
| 2ETD-H36DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR3 | 2 tons24,000 Btu/h · Ducted | 79% | 2.15 | 8.8 | 18.5 | 12.5 | CEE 25CEE 26XcelES CC | 2 | 216699935 | Ducted, 2 tons | 67.9 | 60.2 | 75.7 | 60.2 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | ETD-H60DMR3Also listed as ETD-H48DMR3 | 2.30 | Ducted, 3.5–4.5 tons | 86% | 216699937 |
| Capacity retention at 5°F | ETD-H36DMR3Also listed as ETD-H24DMR3 | 79% | Ducted, 2 tons | 56% | 216699935 |
| HSPF2 | ETD-H60DMR3Also listed as ETD-H48DMR3 | 9.2 | Ducted, 3.5–4.5 tons | 74% | 216699937 |
| SEER2 | ETD-H60DMR3Also listed as ETD-H48DMR3 | 18.5 | Ducted, 3.5–4.5 tons | 81% | 216699937 |
| EER2 | ETD-H36DMR3Also listed as ETD-H24DMR3 | 12.5 | Ducted, 2 tons | 81% | 216699935 |
| Heating capacity at 5°F | ETD-H60DMR3 | 40,000 Btu/h | Ducted, 3.5–4.5 tons | 68% | 216699938 |
Emeric size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 60.2(50 is the typical model of its size class)ETD-H36DMR3with ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR32 of 2 models qualify · AHRI 216699935 | 67.9(50 is the typical model of its size class)ETD-H36DMR3with ducted air handler EAH-C24DMR3Also listed as ETD-H24DMR32 of 2 models have all five ratings · AHRI 216699935 |
| Ducted, 3.5–4.5 tons | 72.2(50 is the typical model of its size class)ETD-H60DMR3with ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR32 of 2 models qualify · AHRI 216699937 | 72.6(50 is the typical model of its size class)ETD-H60DMR3with ducted air handler EAH-C48DMR3Also listed as ETD-H48DMR32 of 2 models have all five ratings · AHRI 216699937 |
Newest Emeric certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| ETD-H48DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C48DMR3 | 4 tons47,000 Btu/h · Ducted | 2.30 | 72% | 9.2 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218448111 |
| ETD-H24DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C24DMR3 | 2 tons24,000 Btu/h · Ducted | 2.15 | 79% | 8.8 | 18.5 | CEE 25CEE 26XcelES CC | 1 | 218448110 |
| ETD-H60DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C60DMR3 | 4.5 tons55,000 Btu/h · Ducted | 2.30 | 73% | 8.8 | 17.0 | CEE 25CEE 26XcelES CC | 2 | 216699938 |
| ETD-H36DMR3Emeric · R32 18 Serieswith ducted air handler EAH-C36DMR3 | 3 tons33,000 Btu/h · Ducted | 2.00 | 73% | 8.8 | 18.0 | CEE 25CEE 26XcelES CC | 2 | 216699936 |
Compare Emeric
Emeric includes these brand names as listed in AHRI: Emeric. Standards are checked against published thresholds; program rules beyond ratings are not checked.